Tetsuo Minamino
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Tetsuo Minamino has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Hiroyuki Kitajima
Faculty of Engineering and Design, Kagawa University
2 shared publications - Kentaro Takeda
Faculty of Engineering and Design, Kagawa University
2 shared publications - Makoto Ishizawa
Faculty of Medicine, Kagawa University
2 shared publications - Kazuyuki Aihara
International Research Center for Neurointelligence, The University of Tokyo Institutes for Advanced Study, The University of Tokyo, Tokyo, Japan
1 shared publication
Latest Publications
- Open Access
- 1 January 2026
- Published by Institute of Electronics, Information and Communications Engineers (IEICE) in Nonlinear Theory and Its Applications, IEICE
- Vol. 17 (1) , 228-239
Atrial fibrillation detection using reservoir computing and anomaly detection method from automated blood pressure measurements
We propose a method for detecting abnormal cardiac rhythms—such as those associated with atrial fibrillation (AF)—from pulse waves measured by an automated blood pressure monitor. The method is based on reservoir computing and detects anomalies by evaluating the prediction error of a model trained solely on normal (sinus rhythm, SR) data. Hyperparameters were tuned using a validation set containing both SR and AF samples. Our method achieved a sensitivity of 100.0%, specificity of 98.6%, and accuracy of 99.2% on an independent test set, outperforming previously reported results. Our results suggest its potential as a cost-effective and accurate embedded screening device for identifying abnormal cardiac rhythms in daily health monitoring.
- 1 January 2026
- Published by Institute of Electronics, Information and Communications Engineers (IEICE) in Nonlinear Theory and Its Applications, IEICE
- Vol. 17 (1) , 228-239
Open AccessAtrial fibrillation detection using reservoir computing and anomaly detection method from automated blood pressure measurements
We propose a method for detecting abnormal cardiac rhythms—such as those associated with atrial fibrillation (AF)—from pulse waves measured by an automated blood pressure monitor. The method is based on reservoir computing and detects anomalies by evaluating the prediction error of a model trained solely on normal (sinus rhythm, SR) data. Hyperparameters were tuned using a validation set containing both SR and AF samples. Our method achieved a sensitivity of 100.0%, specificity of 98.6%, and accuracy of 99.2% on an independent test set, outperforming previously reported results. Our results suggest its potential as a cost-effective and accurate embedded screening device for identifying abnormal cardiac rhythms in daily health monitoring.
- Open Access
- 1 March 2025
- Published by AIP Publishing in Chaos: An Interdisciplinary Journal of Nonlinear Science
- Vol. 35 (3)
Detection of atrial fibrillation from pulse waves using convolution neural networks and recurrence-based plots
We propose a classification method for distinguishing atrial fibrillation from sinus rhythm in pulse-wave measurements obtained with a blood pressure monitor. This method combines recurrence-based plots with convolutional neural networks. Moreover, we devised a novel plot, with which our classification achieved specificity of 97.5%, sensitivity of 98.4%, and accuracy of 98.6%. These criteria are higher than previously reported results for measurements obtained with blood pressure monitors and are almost equal to statistical measures for methods based on electrocardiographs and photoplethysmographs.
- 1 March 2025
- Published by AIP Publishing in Chaos: An Interdisciplinary Journal of Nonlinear Science
- Vol. 35 (3)
Open AccessDetection of atrial fibrillation from pulse waves using convolution neural networks and recurrence-based plots
We propose a classification method for distinguishing atrial fibrillation from sinus rhythm in pulse-wave measurements obtained with a blood pressure monitor. This method combines recurrence-based plots with convolutional neural networks. Moreover, we devised a novel plot, with which our classification achieved specificity of 97.5%, sensitivity of 98.4%, and accuracy of 98.6%. These criteria are higher than previously reported results for measurements obtained with blood pressure monitors and are almost equal to statistical measures for methods based on electrocardiographs and photoplethysmographs.