Zihan Zhao
Zihan Zhao has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Amr Tolba
Computer Science and Engineering Department, College of Applied Studies, King Saud University, Riyadh, Saudi Arabia
3 shared publications - Franck Junior Aboya Messou2 shared publications
- Jinhua Chen
School of Computer Science, South China Normal University, Guangzhou, China
2 shared publications - Keping Yu
Hosei University
2 shared publications - Qiaozhi Hua
Computer School, Hubei University of Arts and Science, Xiangyang, China
2 shared publications - Weiyu Wang
Hosei University
2 shared publications
Latest Publications
- 17 November 2026
- Published by Elsevier in Applied Energy
- Vol. 427
Learnable delay-stability coupling for energy-information co-optimization in smart grids
- 17 November 2026
- Published by Elsevier in Applied Energy
- Vol. 427
Learnable delay-stability coupling for energy-information co-optimization in smart grids
- Open Access
- 8 March 2026
- Published by Elsevier in SSRN Electronic Journal
Learnable Delay-Stability Coupling for Energy-Information Co-Optimization in Smart Grids
Communication latency in smart grid networks directly impacts power system stability, yet existing approaches treat energy optimization and communication quality-of-service as separate problems. This paper introduces a unified framework that learns the fundamental coupling between communication delay and stability margins through physics-constrained deep learning. A formal bound (Theorem 1) is established showing that the stability margin ρ(τ) decreases linearly with communication delay τ, governed by learnable coupling constants K_i that are trained end-to-end via gradient descent. A second-order correction (Corollary 1) tightens this bound at high delays. The proposed JointOptimizer architecture employs dual-domain graph neural networks to encode power system topology and communication network structure separately, with physics-informed attention masks that respect electrical impedance relationships and causal control dependencies. An auto-scaled initialization eliminates grid-size-specific hyperparameter tuning. Experimental validation on five IEEE standard test cases (14, 30, 39, 57, and 118 buses) demonstrates that the learned coupling constants tighten conservative stability bounds by 18% compared to fixed parameters while maintaining 100% stability under nominal conditions. Independent time-domain DDE simulation confirms the theoretical bound, with the second-order Padé correction reducing the prediction gap from approximately 18% to 3% at high delays. Comprehensive evaluation across 9 architectural baselines, 18 experiment types, and 5 independent seeds with Wilcoxon signed-rank statistical testing establishes the robustness and practical viability of the proposed approach for real-time grid control.
- 8 March 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessLearnable Delay-Stability Coupling for Energy-Information Co-Optimization in Smart Grids
Communication latency in smart grid networks directly impacts power system stability, yet existing approaches treat energy optimization and communication quality-of-service as separate problems. This paper introduces a unified framework that learns the fundamental coupling between communication delay and stability margins through physics-constrained deep learning. A formal bound (Theorem 1) is established showing that the stability margin ρ(τ) decreases linearly with communication delay τ, governed by learnable coupling constants K_i that are trained end-to-end via gradient descent. A second-order correction (Corollary 1) tightens this bound at high delays. The proposed JointOptimizer architecture employs dual-domain graph neural networks to encode power system topology and communication network structure separately, with physics-informed attention masks that respect electrical impedance relationships and causal control dependencies. An auto-scaled initialization eliminates grid-size-specific hyperparameter tuning. Experimental validation on five IEEE standard test cases (14, 30, 39, 57, and 118 buses) demonstrates that the learned coupling constants tighten conservative stability bounds by 18% compared to fixed parameters while maintaining 100% stability under nominal conditions. Independent time-domain DDE simulation confirms the theoretical bound, with the second-order Padé correction reducing the prediction gap from approximately 18% to 3% at high delays. Comprehensive evaluation across 9 architectural baselines, 18 experiment types, and 5 independent seeds with Wilcoxon signed-rank statistical testing establishes the robustness and practical viability of the proposed approach for real-time grid control.
- Open Access
- 21 March 2025
- Published by Elsevier in Blockchain: Research and Applications
- Vol. 6 (3)
Federated Large Domain Model System
- 21 March 2025
- Published by Elsevier in Blockchain: Research and Applications
- Vol. 6 (3)
Open AccessFederated Large Domain Model System