SISoichiro Ishiuchi

Soichiro Ishiuchi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Soichiro Ishiuchi has a total of 21 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Dual-layer spectral detector CT for improved assessment of right adrenal vein in patients with primary aldosteronism

    by Ryuya Yoshida, Yasunori Nagayama, Takumi Esaki, Taiga Matsumoto, Yoshitaka Tamura, Soichiro Ishiuchi, Taihei Inoue, Daisuke Sakabe, Yasuaki Igarashi, Masafumi Kidoh, et al.

    Purpose: To investigate whether virtual-monoenergetic images (VMI) from dual-layer spectral-detector computed tomography (DLCT) improve right adrenal vein (RAV) assessment before adrenal venous sampling (AVS), and portal-venous-phase (PVP) images alone can replace conventional multiphase CT combining late-arterial phase (LAP) and PVP. Methods: Sixty-three patients with primary aldosteronism who underwent LAP and PVP DLCT before AVS were retrospectively analyzed. Conventional polyenergetic-images (PEI) and VMI at 40–70 keV (VMI 40–70 ) were reconstructed. Image noise and contrast-to-noise ratio (CNR) of RAV were quantified. VMI with the highest CNR was predefined as the best-VMI. Two radiologists evaluated four image series (PEI and best-VMI at LAP and PVP) separately for RAV visibility, accessory hepatic vein (AHV) assessability, and image noise using five-point scales (1 = worst, 5 = best). RAV detection and AHV assessability rates were compared among image series. Results: In both enhancement phases, VMI 40–70 showed lower image noise and VMI 40–60 higher CNR than PEI (all p < 0.05), with VMI 40 providing the highest CNR and being designated as the best VMI. Compared to PEI at LAP, CNR was lower with PEI at PVP but higher with VMI 40 at PVP (both, p < 0.001). In subjective analysis, VMI 40 showed better scores than PEI for image noise (LAP: 4.0 ± 0.5 vs. 2.4 ± 0.6; PVP: 4.0 ± 0.6 vs. 2.5 ± 0.5) and RAV visibility (LAP: 4.5 ± 0.8 vs. 3.5 ± 0.8; PVP: 3.7 ± 1.0 vs. 2.6 ± 0.9) (all p < 0.001). With PEI, the RAV detection rate was lower at PVP than at LAP (54.8% vs. 89.7%, p < 0.001). Use of VMI 40 at PVP achieved the same detection rate as PEI at LAP (89.7%, p = 1.0) and higher AHV assessability rate than PEI at PVP (96.8% vs. 80.2%, p < 0.001). Conclusion: DLCT-VMI improved RAV assessments before AVS. Using VMI 40 for PVP provided RAV depiction equivalent to PEI at LAP and superior AHV assessability to PEI at PVP, suggesting its potential as a surrogate for dedicated multiphase CT.


  • Usefulness of 3T split acquisition fast spin-echo diffusion-weighted imaging for differentiating pituitary abscess from other sellar cystic lesions: a preliminary study

    by Soichiro Ishiuchi, Hiroyuki Uetani, Naoki Shinojima, Takeshi Nakaura, Mika Kitajima, Kosuke Morita, Kouji Ogasawara, Masami Yoneyama, Akitake Mukasa, Toshinori Hirai

    Purpose Pituitary abscess is a rare condition that can be challenging to distinguish from other sellar cystic lesions (OSCLs) due to no specific symptoms and overlapping imaging features. Accurate differentiation is crucial for appropriate treatment planning. This study aimed to evaluate the usefulness of 3T split acquisition fast spin-echo diffusion-weighted imaging (SPLICE-DWI) in differentiating pituitary abscesses from OSCLs. Methods We retrospectively analyzed magnetic resonance imaging (MRI) data from 32 patients with sellar cystic lesions, including 5 with pathologically confirmed pituitary abscesses and 27 with OSCLs. Conventional MRI sequences and SPLICE-DWI were performed, and apparent diffusion coefficient (ADC) values were calculated. Qualitative assessments of signal intensity on SPLICE-DWI and conventional MRI were conducted by two neuroradiologists. The diagnostic performance of these imaging parameters was evaluated using receiver operating characteristic (ROC) analysis. Results SPLICE-DWI successfully differentiated pituitary abscesses from OSCLs, showing significantly lower ADC values in the abscess group compared to OSCLs (0.62 ± 0.07 × 10− 3 mm²/s vs. 1.83 ± 0.70 × 10− 3 mm²/s, P = 0.002). ROC analysis revealed high diagnostic accuracy for DWI signal intensity (AUC = 0.89) and ADC values (AUC = 0.95). No significant differences were found in contrast-enhanced T1-weighted imaging (T1WI) features such as ring enhancement, pituitary stalk enlargement, or sphenoid sinus mucosal thickening between the two groups. Conclusion SPLICE-DWI is a valuable tool for the differentiation of pituitary abscesses from OSCLs, offering high diagnostic accuracy.