Deysi Vilma Inca Balseca
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Deysi Vilma Inca Balseca has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Carlos Ramiro Penafiel-Ojeda
Universidad Nacional de Chimborazo
1 shared publication - Cristian Vacacela Gomez
Universidad Ecotec, Km. 13.5 Samborondon, Samborondon 092302, Ecuador
1 shared publication - José Luis Jinez Tapia
Universidad Nacional de Chimborazo
1 shared publication - Juan Carlos Tixi Pintag
Investigador Independiente, Riobamba 060110, Provincia de Chimborazo, Ecuador
1 shared publication - Luis Gonzalo Santillán-Valdiviezo
Grupo de Investigación GI (CT), Facultad de Ingeniería, Carrera de Telecomunicaciones, Universidad Nacional de Chimborazo, Riobamba 060108, Provincia de Chimborazo, Ecuador
1 shared publication - Paola Gabriela Vinueza Naranjo
College of Engineering, Universidad Nacional de Chimborazo, Riobamba 060108, Ecuador
1 shared publication
Latest Publications
- Open Access
- 11 November 2025
- Published by MDPI AG in Biomechanics
- Vol. 5 (4) , 96
Design and Testing of a Biomechanical Device for Pediatric Spastic Hand Rehabilitation
Background: Children with spastic hand impairments resulting from cerebral palsy or neuromuscular disorders often exhibit a restricted range of motion and diminished functional use. Rehabilitation devices that assist joint mobilization can enhance therapeutic outcomes, yet few solutions target pediatric populations. Methods: This study aimed to design, implement, and preliminarily evaluate a biomechanical device tailored to promote flexo-extension, radial–ulnar deviation, and supination movements in spastic hands of school-aged children. A prototype combining a motor-driven actuation system, adjustable wrist and finger supports, and a MATLAB-based graphical user interface was developed. Two participants (aged 8 and 10) with clinically diagnosed spastic hemiparesis underwent 25-minute sessions over 15 consecutive days. Joint angles were recorded before and after each session using an electro-goniometer. Data normality was assessed via the Shapiro–Wilk test, and pre–post differences were analyzed with the Wilcoxon signed-rank test (α = 0.05). Results: Both participants demonstrated consistent increases in their active range of motion across all measured planes. Median flexo-extension improved by 12.5° (p = 0.001), ulnar–radial deviation by 7.3° (p = 0.002), and supination by 9.1° (p = 0.001). No adverse events occurred, and device tolerance remained high throughout the intervention. Conclusions: The device facilitated statistically significant enhancements in joint mobility in a small pediatric cohort, supporting its feasibility and safety in spastic hand rehabilitation. These preliminary findings warrant larger controlled trials to confirm the device’s efficacy, optimize treatment protocols, and assess its long-term functional benefits.
- 11 November 2025
- Published by MDPI AG in Biomechanics
- Vol. 5 (4) , 96
Open AccessDesign and Testing of a Biomechanical Device for Pediatric Spastic Hand Rehabilitation
Background: Children with spastic hand impairments resulting from cerebral palsy or neuromuscular disorders often exhibit a restricted range of motion and diminished functional use. Rehabilitation devices that assist joint mobilization can enhance therapeutic outcomes, yet few solutions target pediatric populations. Methods: This study aimed to design, implement, and preliminarily evaluate a biomechanical device tailored to promote flexo-extension, radial–ulnar deviation, and supination movements in spastic hands of school-aged children. A prototype combining a motor-driven actuation system, adjustable wrist and finger supports, and a MATLAB-based graphical user interface was developed. Two participants (aged 8 and 10) with clinically diagnosed spastic hemiparesis underwent 25-minute sessions over 15 consecutive days. Joint angles were recorded before and after each session using an electro-goniometer. Data normality was assessed via the Shapiro–Wilk test, and pre–post differences were analyzed with the Wilcoxon signed-rank test (α = 0.05). Results: Both participants demonstrated consistent increases in their active range of motion across all measured planes. Median flexo-extension improved by 12.5° (p = 0.001), ulnar–radial deviation by 7.3° (p = 0.002), and supination by 9.1° (p = 0.001). No adverse events occurred, and device tolerance remained high throughout the intervention. Conclusions: The device facilitated statistically significant enhancements in joint mobility in a small pediatric cohort, supporting its feasibility and safety in spastic hand rehabilitation. These preliminary findings warrant larger controlled trials to confirm the device’s efficacy, optimize treatment protocols, and assess its long-term functional benefits.
- Open Access
Black Phosphorous-Based Surface Plasmon Resonance Biosensor for Malaria Diagnosis
This study presents a black phosphorus-based surface plasmon resonance (SPR) biosensor for malaria detection, integrating silicon nitride (Si3N4) and single-stranded DNA (ssDNA) to enhance sensitivity and molecular recognition. The biosensor configurations were optimized through numerical simulations, evaluating metal thickness, dielectric layer thickness, and the number of black phosphorus layers to achieve maximum performance. The optimized system (Opt-Sys4) exhibited high sensitivity (464.4°/RIU for early-stage malaria) and improved detection accuracy, outperforming conventional SPR sensors. Performance was assessed across malaria progression stages, demonstrating a clear resonance shift, increased attenuation, and enhanced biomolecular interactions. Key metrics, including the figure of merit, limit of detection, and comprehensive sensitivity factor, confirmed the sensor’s superior performance. Comparative analysis against state-of-the-art SPR biosensors further validated their capability for highly sensitive and specific malaria detection. These findings establish a promising plasmonic biosensing platform for early malaria diagnosis, potentially improving disease management in resource-limited settings.
Open AccessBlack Phosphorous-Based Surface Plasmon Resonance Biosensor for Malaria Diagnosis
This study presents a black phosphorus-based surface plasmon resonance (SPR) biosensor for malaria detection, integrating silicon nitride (Si3N4) and single-stranded DNA (ssDNA) to enhance sensitivity and molecular recognition. The biosensor configurations were optimized through numerical simulations, evaluating metal thickness, dielectric layer thickness, and the number of black phosphorus layers to achieve maximum performance. The optimized system (Opt-Sys4) exhibited high sensitivity (464.4°/RIU for early-stage malaria) and improved detection accuracy, outperforming conventional SPR sensors. Performance was assessed across malaria progression stages, demonstrating a clear resonance shift, increased attenuation, and enhanced biomolecular interactions. Key metrics, including the figure of merit, limit of detection, and comprehensive sensitivity factor, confirmed the sensor’s superior performance. Comparative analysis against state-of-the-art SPR biosensors further validated their capability for highly sensitive and specific malaria detection. These findings establish a promising plasmonic biosensing platform for early malaria diagnosis, potentially improving disease management in resource-limited settings.