Márta Katona
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Márta Katona has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Eszter Hódi
Department of Obstetrics and Gynecology, University of Szeged, 6725 Szeged, Hungary
2 shared publications - Hajnalka Orvos
Department of Obstetrics and Gynecology, Albert Szent-Györgyi Medical School, University of Szeged, 6725 Szeged, Hungary
2 shared publications - Zita Gyurkovits
Department of Obstetrics and Gynecology, University of Szeged, 6725 Szeged, Hungary
2 shared publications - Gyula Pásztor
Department of Radiology, Albert Szent-Györgyi Health Center, University of Szeged, 6725 Szeged, Hungary
1 shared publication - Szabolcs Várbíró
Department of Obstetrics and Gynecology, Albert Szent-Györgyi Medical School, University of Szeged, 6725 Szeged, Hungary
1 shared publication - Zsófia Fritsch
Department of Obstetrics and Gynecology, University of Szeged, 6725 Szeged, Hungary
1 shared publication
Latest Publications
- Open Access
- 10 September 2026
- Published by MDPI AG in Journal of Personalized Medicine
- Vol. 16 (9) , 467
Complex Screening for Congenital Cardiovascular Malformations
Importance: Congenital heart defects constitute the most prevalent developmental abnormality. Among these, critical congenital heart defects are associated with substantial morbidity and mortality if not promptly identified. Objective: To evaluate the screening performance of a newborn protocol combining prenatal ultrasonography, postnatal physical examination, and pulse oximetry screening, with particular attention being paid to the timing of the postnatal examination. This is an evaluation of screening performance in a single centre and not a study of birth prevalence. Methods: We performed a retrospective cohort study of all live-born infants delivered at University of Szeged, Hungary, between 2019 and 2024. Screening comprised prenatal ultrasonography, postnatal physical examination within 24 h and at a 48–72 h range, and pulse oximetry screening at 24 ± 6 h. The primary outcome was an echocardiographically confirmed congenital heart defect, classified as critical, severe, requiring surgical correction after one year of age, or minimal. Isolated patent foramen ovale, isolated patent ductus arteriosus when the only echocardiogram was performed before 21 days of age, and a patent duct in preterm infants were classified as transitional findings and were excluded. Proportions are reported with exact (Clopper–Pearson) 95% confidence intervals and groups were compared using Fisher’s exact test. Results: Among 13,979 live births, 123 infants had an echocardiographically confirmed structural defect of the heart or great vessels detected through screening; a further 39 infants had transitional findings. Postnatal physical examination accounted for 107/123 (87.0%, 95% confidence interval range: 79.7–92.4) of the cases detected by screening; because echocardiography was not performed in screen-negative infants and defects presenting after discharge were not systematically traced, this is the share of screen-detected cases and not the sensitivity of the examination. The second examination at the 48–72 h range accounted for 92/123 (74.8%, 66.2–82.2), including 3 critical and 5 severe defects in which the first examination had shown no abnormality. Prenatal ultrasonography identified 6/16 (37.5%, 15.2–64.6) of critical and severe defects, and 15/123 (12.2%, 7.0–19.3) of all structural defects. The latter figure is not a prenatal detection rate, since there are lesions that cannot be identified before birth. Pulse oximetry screening identified 1/123 (0.8%, 0.0–4.4) after negative prenatal ultrasonography and no clinical signs. The combined protocol detected 123 of the 124 infants known to have a structural defect (99.2%) before discharge; this is a detection rate among known cases. Critical defects were identified in at least 0.50 per 1000 live births and critical plus severe defects in at least 1.14 per 1000; these are lower limits for live births in one centre, not birth prevalence estimates. Interpretations: Repeated postnatal physical examination provided the highest yield, while prenatal ultrasonography contributed mainly to severe and critical defect detection; pulse oximetry screening added few additional cases but remains an important modality. Where discharge occurs before 48 h, a second cardiac examination should be arranged at a range of 48–72 h of age, and a cardiology review between two and six weeks is advisable, since small muscular ventricular septal defects and duct-dependent left-heart obstruction may not be apparent in the first days of life.
- 10 September 2026
- Published by MDPI AG in Journal of Personalized Medicine
- Vol. 16 (9) , 467
Open AccessComplex Screening for Congenital Cardiovascular Malformations
Importance: Congenital heart defects constitute the most prevalent developmental abnormality. Among these, critical congenital heart defects are associated with substantial morbidity and mortality if not promptly identified. Objective: To evaluate the screening performance of a newborn protocol combining prenatal ultrasonography, postnatal physical examination, and pulse oximetry screening, with particular attention being paid to the timing of the postnatal examination. This is an evaluation of screening performance in a single centre and not a study of birth prevalence. Methods: We performed a retrospective cohort study of all live-born infants delivered at University of Szeged, Hungary, between 2019 and 2024. Screening comprised prenatal ultrasonography, postnatal physical examination within 24 h and at a 48–72 h range, and pulse oximetry screening at 24 ± 6 h. The primary outcome was an echocardiographically confirmed congenital heart defect, classified as critical, severe, requiring surgical correction after one year of age, or minimal. Isolated patent foramen ovale, isolated patent ductus arteriosus when the only echocardiogram was performed before 21 days of age, and a patent duct in preterm infants were classified as transitional findings and were excluded. Proportions are reported with exact (Clopper–Pearson) 95% confidence intervals and groups were compared using Fisher’s exact test. Results: Among 13,979 live births, 123 infants had an echocardiographically confirmed structural defect of the heart or great vessels detected through screening; a further 39 infants had transitional findings. Postnatal physical examination accounted for 107/123 (87.0%, 95% confidence interval range: 79.7–92.4) of the cases detected by screening; because echocardiography was not performed in screen-negative infants and defects presenting after discharge were not systematically traced, this is the share of screen-detected cases and not the sensitivity of the examination. The second examination at the 48–72 h range accounted for 92/123 (74.8%, 66.2–82.2), including 3 critical and 5 severe defects in which the first examination had shown no abnormality. Prenatal ultrasonography identified 6/16 (37.5%, 15.2–64.6) of critical and severe defects, and 15/123 (12.2%, 7.0–19.3) of all structural defects. The latter figure is not a prenatal detection rate, since there are lesions that cannot be identified before birth. Pulse oximetry screening identified 1/123 (0.8%, 0.0–4.4) after negative prenatal ultrasonography and no clinical signs. The combined protocol detected 123 of the 124 infants known to have a structural defect (99.2%) before discharge; this is a detection rate among known cases. Critical defects were identified in at least 0.50 per 1000 live births and critical plus severe defects in at least 1.14 per 1000; these are lower limits for live births in one centre, not birth prevalence estimates. Interpretations: Repeated postnatal physical examination provided the highest yield, while prenatal ultrasonography contributed mainly to severe and critical defect detection; pulse oximetry screening added few additional cases but remains an important modality. Where discharge occurs before 48 h, a second cardiac examination should be arranged at a range of 48–72 h of age, and a cardiology review between two and six weeks is advisable, since small muscular ventricular septal defects and duct-dependent left-heart obstruction may not be apparent in the first days of life.
- Open Access
The Occurrence of Supernumerary Umbilical Cord Vessels: A Review for Practicing Clinicians
Background: The umbilical cord normally contains two arteries and one vein. The presence of supernumerary—four or five—umbilical cord vessels is a rare phenomenon, with few cases reported in the literature. The majority of cases are detected postnatally. However, given their potential association with developmental abnormalities, primarily severe cardiac anomalies and genetic disorders, the prenatal diagnosis of supernumerary umbilical cord vessels may have clinical relevance. Methods: A review of the clinical phenomenon of the four-vessel umbilical cord and its complications was conducted using case studies and literature reviews in PubMed from 1977 to the present and in Google Scholar from 1966 to the present. Results: Among the 24 reported cases, 7 cases were associated with malformations, 8 cases were detected antenatally, and 16 cases postpartum. Among the eight antenatally diagnosed cases, only one had a congenital malformation, hydrops fetalis. Among the postnatally diagnosed cases, six had congenital abnormalities: three were cardiovascular, two were associated with hydrops, urinary, gastrointestinal, and skeletal disorders, hypoplastic corpus callosum, and dysmorphic facial features. Conclusions: Four-vessel umbilical cords are more frequent than previously thought, as they can be easily overlooked during the mandatory ultrasound examination. A review of the literature revealed a correlation between supernumerary umbilical cord vessels and major congenital malformations, underscoring the significance of prenatal diagnosis; however, the four-vessel cord may not always be indicative of a serious condition.
Open AccessThe Occurrence of Supernumerary Umbilical Cord Vessels: A Review for Practicing Clinicians
Background: The umbilical cord normally contains two arteries and one vein. The presence of supernumerary—four or five—umbilical cord vessels is a rare phenomenon, with few cases reported in the literature. The majority of cases are detected postnatally. However, given their potential association with developmental abnormalities, primarily severe cardiac anomalies and genetic disorders, the prenatal diagnosis of supernumerary umbilical cord vessels may have clinical relevance. Methods: A review of the clinical phenomenon of the four-vessel umbilical cord and its complications was conducted using case studies and literature reviews in PubMed from 1977 to the present and in Google Scholar from 1966 to the present. Results: Among the 24 reported cases, 7 cases were associated with malformations, 8 cases were detected antenatally, and 16 cases postpartum. Among the eight antenatally diagnosed cases, only one had a congenital malformation, hydrops fetalis. Among the postnatally diagnosed cases, six had congenital abnormalities: three were cardiovascular, two were associated with hydrops, urinary, gastrointestinal, and skeletal disorders, hypoplastic corpus callosum, and dysmorphic facial features. Conclusions: Four-vessel umbilical cords are more frequent than previously thought, as they can be easily overlooked during the mandatory ultrasound examination. A review of the literature revealed a correlation between supernumerary umbilical cord vessels and major congenital malformations, underscoring the significance of prenatal diagnosis; however, the four-vessel cord may not always be indicative of a serious condition.