Xuan Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Xuan Liu has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Kunpeng Li
School of Information Science and Technology, Northwest University , Xi’an, Shannxi 710127
2 shared publications - Sheng Tang
School of Information science and Technology, Northwest University, Xian, Shaanxi, China
2 shared publications - Xiaowei He
Northwest University
2 shared publications - Yuqing Hou
Xian Key Lab of Radiomics and Intelligent Perception, School of Information Science and Technology, Northwest University, Xian, China
2 shared publications - Kaixuan Wang
School of Information Science and Technology, Northwest University , Xi’an, Shannxi 710127
1 shared publication - Sujing Song
School of Information Science and Technology, Northwest University , Xi’an, Shannxi 710127
1 shared publication
Latest Publications
- 1 May 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (5)
Improved strong tracking Sage–Husa adaptive algorithm for multi-MEMS IMU data fusion
A circuit array of 16 micro-electro-mechanical system inertial measurement unit (IMUs) is developed, and an improved multi-IMU data fusion method based on the strong tracking Sage–Husa adaptive Kalman filter (ST-SHAKF) is proposed to achieve high-precision inertial measurement at low cost. The traditional Sage–Husa adaptive (SHAKF) algorithm is simplified for adaptive parameterization, with improved measurement noise variance estimation to ensure positive-definiteness. Filter divergence is addressed by supplementing the SHAKF with a strong tracking filter to maintain convergence. Dynamic weight allocation via minimum variance estimation enables effective multi-IMU data fusion. Experiments show that the proposed method significantly outperforms the traditional Sage–Husa adaptive Kalman filter in terms of Allan variance and standard deviation. Compared to traditional SHAKF, the proposed method achieves better noise suppression and improved fusion accuracy for both acceleration and angular velocity under both static and dynamic conditions.
- 1 May 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (5)
Improved strong tracking Sage–Husa adaptive algorithm for multi-MEMS IMU data fusion
A circuit array of 16 micro-electro-mechanical system inertial measurement unit (IMUs) is developed, and an improved multi-IMU data fusion method based on the strong tracking Sage–Husa adaptive Kalman filter (ST-SHAKF) is proposed to achieve high-precision inertial measurement at low cost. The traditional Sage–Husa adaptive (SHAKF) algorithm is simplified for adaptive parameterization, with improved measurement noise variance estimation to ensure positive-definiteness. Filter divergence is addressed by supplementing the SHAKF with a strong tracking filter to maintain convergence. Dynamic weight allocation via minimum variance estimation enables effective multi-IMU data fusion. Experiments show that the proposed method significantly outperforms the traditional Sage–Husa adaptive Kalman filter in terms of Allan variance and standard deviation. Compared to traditional SHAKF, the proposed method achieves better noise suppression and improved fusion accuracy for both acceleration and angular velocity under both static and dynamic conditions.
- 26 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-10
A Noncontact Sleep Monitoring Method Based on Millimeter-Wave Radar
High quality sleep is a fundamental guarantee for human physical health. Sleep monitoring is crucial for understanding sleep quality and structure, but traditional sleep monitoring methods often require specialized lab environments and uncomfortable sensors. This paper proposes a non-contact sleep monitoring method based on millimeter wave radar, which accurately measures breathing and heartbeat rates during sleep by preprocessing reflected signals and using Variational Mode Extraction (VME) algorithm, and simultaneously detects snoring events. In order to improve the accuracy of snoring detection, a sliding window algorithm based on data density and amplitude is introduced, effectively filtering out low-amplitude noise and accurately identifying snoring segments. Experimental results show that this method can detect snoring events with an average error of 0.10 seconds, and the accuracy of breathing rate and heart rate detection is approximately 0.72 bpm and 2.56 bpm, respectively. This method demonstrates high real-time performance and reliability, and is expected to find broad applications in the diagnosis of clinical sleep disorders and home health monitoring.
- 26 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-10
A Noncontact Sleep Monitoring Method Based on Millimeter-Wave Radar
High quality sleep is a fundamental guarantee for human physical health. Sleep monitoring is crucial for understanding sleep quality and structure, but traditional sleep monitoring methods often require specialized lab environments and uncomfortable sensors. This paper proposes a non-contact sleep monitoring method based on millimeter wave radar, which accurately measures breathing and heartbeat rates during sleep by preprocessing reflected signals and using Variational Mode Extraction (VME) algorithm, and simultaneously detects snoring events. In order to improve the accuracy of snoring detection, a sliding window algorithm based on data density and amplitude is introduced, effectively filtering out low-amplitude noise and accurately identifying snoring segments. Experimental results show that this method can detect snoring events with an average error of 0.10 seconds, and the accuracy of breathing rate and heart rate detection is approximately 0.72 bpm and 2.56 bpm, respectively. This method demonstrates high real-time performance and reliability, and is expected to find broad applications in the diagnosis of clinical sleep disorders and home health monitoring.