Chuanjin Cui
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Chuanjin Cui has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
Jingdong Bo
College of Electrical Engineering, North China University of Science and Technology, Tangshan, Hebei, People’s Republic of China
2 shared publicationsChuang Pan
College of Electrical Engineering, North China University of Science and Technology, Tangshan, Hebei, People’s Republic of China
1 shared publication- Fei Deng
Graduate School of Biomedical Engineering, Faculty of Engineering, University of New South Wales, Sydney, NSW 2052, Australia
1 shared publication - Haobo Liu
School of Electrical Engineering, North China University of Science and Technology, Tangshan 063000, China
1 shared publication - Jianlong Zhao
State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai, China
1 shared publication Jianxin Cheng
Xiangfu Laboratory , Jiaxing , Zhejiang Province , Jiashan China
1 shared publication
Latest Publications
- Open Access
- 2 April 2026
- Published by MDPI AG in Biosensors
- Vol. 16 (4) , 202
Droplet-Interlaced Generator with On-Chip Metal–Liquid Micromirrors for Enhanced Microfluidic Absorbance Detection
Droplet microfluidics has been widely used in biological, chemical, and medical research owing to its advantages of miniaturization, high throughput, and low reagent consumption. However, limited sensitivity and optical path length in on-chip absorbance detection remain major challenges for droplet-based microfluidic analysis. Traditional absorbance detection suffers from low sensitivity due to the extremely short optical path in microfluidic channels, while existing optical path extension methods have drawbacks such as complex fabrication, easy droplet rupture, or strict incident angle requirements. To address these issues, this study developed a droplet microfluidic absorbance detection platform integrating optical fibers, on-chip micromirrors, external fluidic actuation, and an absorbance detection module. Microchannel sidewalls filled with low-melting-point metal act as mirrors; the multi-reflection optical path, combined with optical fibers and micromirrors, compensates for insufficient light manipulation and effectively extends the absorption path length, improving sensitivity and accuracy. Using this method, the detection limit for methylene blue solution was 20 μM, and the sensitivity for Escherichia coli (E. coli) suspension was doubled compared with traditional Nanodrop OD600 measurement. This device features low fabrication difficulty and cost and stable detection, providing a proof-of-concept strategy for enhanced absorbance detection in droplet microfluidic systems.
- 2 April 2026
- Published by MDPI AG in Biosensors
- Vol. 16 (4) , 202
Open AccessDroplet-Interlaced Generator with On-Chip Metal–Liquid Micromirrors for Enhanced Microfluidic Absorbance Detection
Droplet microfluidics has been widely used in biological, chemical, and medical research owing to its advantages of miniaturization, high throughput, and low reagent consumption. However, limited sensitivity and optical path length in on-chip absorbance detection remain major challenges for droplet-based microfluidic analysis. Traditional absorbance detection suffers from low sensitivity due to the extremely short optical path in microfluidic channels, while existing optical path extension methods have drawbacks such as complex fabrication, easy droplet rupture, or strict incident angle requirements. To address these issues, this study developed a droplet microfluidic absorbance detection platform integrating optical fibers, on-chip micromirrors, external fluidic actuation, and an absorbance detection module. Microchannel sidewalls filled with low-melting-point metal act as mirrors; the multi-reflection optical path, combined with optical fibers and micromirrors, compensates for insufficient light manipulation and effectively extends the absorption path length, improving sensitivity and accuracy. Using this method, the detection limit for methylene blue solution was 20 μM, and the sensitivity for Escherichia coli (E. coli) suspension was doubled compared with traditional Nanodrop OD600 measurement. This device features low fabrication difficulty and cost and stable detection, providing a proof-of-concept strategy for enhanced absorbance detection in droplet microfluidic systems.
- 9 December 2025
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 35 (12) , 125004
Particle separation chip integrating micro-pillar array with tilted standing surface acoustic wave
Particle separation technology is widely applied in fields such as biomedicine, chemical analysis, and environmental monitoring. As an efficient particle separation method, surface acoustic wave (SAW)-based microfluidic technology enables precise particle manipulation and separation by establishing an acoustic field within microchannels, offering advantages such as device miniaturization, low cost, and ease of integration. This study proposes a novel separation method based on the synergistic interaction between deterministic lateral displacement (DLD) and tilted standing surface acoustic wave. By reconfiguring the function of the DLD array into ‘sheathless focusing units,’ a highly ordered particle inlet flow is provided for subsequent acoustic separation. Experimental results demonstrate that the integrated device successfully achieved high-efficiency separation of 5 µ m and 15 µ m particles, with both purity and efficiency exceeding 98%. Compared to single-technique approaches, this synergistic strategy significantly enhances separation purity, efficiency, and operational stability under sheathless conditions. This study provides a feasible solution for the application of acoustofluidic technology in the field of particle separation, offering certain theoretical reference value and engineering application potential.
- 9 December 2025
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 35 (12) , 125004
Particle separation chip integrating micro-pillar array with tilted standing surface acoustic wave
Particle separation technology is widely applied in fields such as biomedicine, chemical analysis, and environmental monitoring. As an efficient particle separation method, surface acoustic wave (SAW)-based microfluidic technology enables precise particle manipulation and separation by establishing an acoustic field within microchannels, offering advantages such as device miniaturization, low cost, and ease of integration. This study proposes a novel separation method based on the synergistic interaction between deterministic lateral displacement (DLD) and tilted standing surface acoustic wave. By reconfiguring the function of the DLD array into ‘sheathless focusing units,’ a highly ordered particle inlet flow is provided for subsequent acoustic separation. Experimental results demonstrate that the integrated device successfully achieved high-efficiency separation of 5 µ m and 15 µ m particles, with both purity and efficiency exceeding 98%. Compared to single-technique approaches, this synergistic strategy significantly enhances separation purity, efficiency, and operational stability under sheathless conditions. This study provides a feasible solution for the application of acoustofluidic technology in the field of particle separation, offering certain theoretical reference value and engineering application potential.
- Open Access
- 1 January 2025
- Published by Walter de Gruyter GmbH in International Journal on Smart Sensing and Intelligent Systems
- Vol. 18 (1)
Research on real-time nucleic acid detection device based on microfluidic technology
In recent years, the point-of-care testing (POCT) device for nucleic acid detection has received extensive attention. POCT device provides rapid, high sensitivity and accuracy of on-site diagnosis and can quantify the nucleic acid in clinical samples in real time. The integration of microfluidics ensures accurate fluid control, minimizes sample volume, and improves detection efficiency. In addition, POCT devices can conduct multichannel analysis, facilitate continuous monitoring, and provide comprehensive quantitative data. Due to its portability, cost-effectiveness, and ease of use, POCT device represents a promising solution for extensive, reliable, and timely nucleic acid detection in various medical environments. This review summarizes the research and development of nucleic acid detection POCT devices based on microfluidic technology in recent years, and the development trend of the device has prospected.
- 1 January 2025
- Published by Walter de Gruyter GmbH in International Journal on Smart Sensing and Intelligent Systems
- Vol. 18 (1)
Open AccessResearch on real-time nucleic acid detection device based on microfluidic technology
In recent years, the point-of-care testing (POCT) device for nucleic acid detection has received extensive attention. POCT device provides rapid, high sensitivity and accuracy of on-site diagnosis and can quantify the nucleic acid in clinical samples in real time. The integration of microfluidics ensures accurate fluid control, minimizes sample volume, and improves detection efficiency. In addition, POCT devices can conduct multichannel analysis, facilitate continuous monitoring, and provide comprehensive quantitative data. Due to its portability, cost-effectiveness, and ease of use, POCT device represents a promising solution for extensive, reliable, and timely nucleic acid detection in various medical environments. This review summarizes the research and development of nucleic acid detection POCT devices based on microfluidic technology in recent years, and the development trend of the device has prospected.