Ratnamala Mantri (Paswan)
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ratnamala Mantri (Paswan) has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
Rais Abdul Hamid Khan
SOCSE, SANDIP University, Nashik, India
2 shared publications- Deepak Mane
Department of Computer Science & Engineering, VIT, Pune, India
1 shared publication - Pankaj R. Chandre
MIT Art, Design, and Technology University, India
1 shared publication Rahul More
MIT Art Design and Technology University, Pune, Maharashtra 412201, India
1 shared publication- Rais Abdul Hamid Khan
Sandip University, Trimbak Road, Nashik, Maharashtra 422213, India
1 shared publication Sulochana Madachane
1 shared publication
Latest Publications
- Open Access
- 26 November 2026
- Published by Wildlife Information Liaison Development Society in Journal of Threatened Taxa
- Vol. 18 (11)
Improving wild animal visibility in forest surveillance: the role of non-local means filtering in image preprocessing
Wild animal intrusions into human settlements cause injury to people, damage to property, and loss of livestock. Automated detection from camera traps could provide early warning, but images recorded at night under infrared illumination are often noisy, which can reduce detection accuracy. This study compared four image-denoising filters (mean, median, wiener, and non-local means (NLM)) as a preprocessing step for night-time wildlife images. A total of 140 night-time infrared images (1280 × 720 pixels; 35 each of tiger, Asian Black Bear, Sika Deer, & Wild Boar) were selected at random from the Northeast Tiger and Leopard National Park (NTLNP) dataset, converted to greyscale, and corrupted with additive Gaussian noise (σ = 15). Each filter was applied with window sizes of 3 × 3, 5 × 5, and 7 × 7 pixels; for NLM these were the template window sizes. Denoised images were compared with the originals using mean squared error (MSE) and peak signal-to-noise ratio (PSNR). NLM gave the lowest mean MSE in 11 of the 12 species and window-size combinations (mean MSE 2.68–9.07), followed by the wiener filter (6.08–10.33), while the mean (22.99–43.96) and median (25.38–55.54) filters produced much larger errors. These results indicate that NLM is a suitable preprocessing step for automated wildlife detection at night, although its higher computational cost needs to be addressed for real-time use.
- 26 November 2026
- Published by Wildlife Information Liaison Development Society in Journal of Threatened Taxa
- Vol. 18 (11)
Open AccessImproving wild animal visibility in forest surveillance: the role of non-local means filtering in image preprocessing
Wild animal intrusions into human settlements cause injury to people, damage to property, and loss of livestock. Automated detection from camera traps could provide early warning, but images recorded at night under infrared illumination are often noisy, which can reduce detection accuracy. This study compared four image-denoising filters (mean, median, wiener, and non-local means (NLM)) as a preprocessing step for night-time wildlife images. A total of 140 night-time infrared images (1280 × 720 pixels; 35 each of tiger, Asian Black Bear, Sika Deer, & Wild Boar) were selected at random from the Northeast Tiger and Leopard National Park (NTLNP) dataset, converted to greyscale, and corrupted with additive Gaussian noise (σ = 15). Each filter was applied with window sizes of 3 × 3, 5 × 5, and 7 × 7 pixels; for NLM these were the template window sizes. Denoised images were compared with the originals using mean squared error (MSE) and peak signal-to-noise ratio (PSNR). NLM gave the lowest mean MSE in 11 of the 12 species and window-size combinations (mean MSE 2.68–9.07), followed by the wiener filter (6.08–10.33), while the mean (22.99–43.96) and median (25.38–55.54) filters produced much larger errors. These results indicate that NLM is a suitable preprocessing step for automated wildlife detection at night, although its higher computational cost needs to be addressed for real-time use.
- Open Access
- 15 October 2025
- Published by Asian Research Association in International Research Journal of Multidisciplinary Technovation
- p. 27-40
YOLO-Based Generalized Framework for Leukemia Cell Detection Using Unified Microscopic Image Datasets
Acute lymphoblastic leukemia is a kind of blood cancer that attacks the lymphoblast, a subgroup of white blood cells. Leukemia is a potentially lethal hematological cancer that requires prompt diagnosis. A skilled manual blood smear examination is one of the laborious and prone to human error conventional diagnostic methods. Although current automated methods developed by researchers use either single-cell or multi-cell pictures to detect leukemia cells, they frequently lack model generalization that perform better on heterogeneous datasets. They are also insufficient for deployment in real time. This study aims to develop generalized real-time system for detecting ALL cells from single and multi-cell microscopic blood smear images. The system utilizes three YOLO based state-of-the-art models: YOLO11, YOLOv8 and YOLOv5. The core novelty of this study lies in the creation of a unified dataset that integrates both single-cell and multi-cell microscopic blood smear images, this enables the model to learn generalized representations from diverse image contexts. Three datasets are merged to create the unified dataset, ALL-IDB1: multi- cell images, ALL-IDB2 & C-NMC-19: single-cell images. Image annotation and preprocessing are performed using Roboflow platform, while Google Colab is used for training and testing. These models are trained separately on individual datasets and the unified dataset.The performance of generalized YOLO models is assessed and contrasted against dataset-specific models using mAP@50 and recall metrics on the same set of unseen images from all three datasets.The experimental results indicate that generalized YOLOv8 model achieved notably high recall and competitive map@50, demonstrating strong adaptability and accuracy. These results highlight YOLOv8 as a promising solution for developing generalized model for leukemia cell detection.
- 15 October 2025
- Published by Asian Research Association in International Research Journal of Multidisciplinary Technovation
- p. 27-40
Open AccessYOLO-Based Generalized Framework for Leukemia Cell Detection Using Unified Microscopic Image Datasets
Acute lymphoblastic leukemia is a kind of blood cancer that attacks the lymphoblast, a subgroup of white blood cells. Leukemia is a potentially lethal hematological cancer that requires prompt diagnosis. A skilled manual blood smear examination is one of the laborious and prone to human error conventional diagnostic methods. Although current automated methods developed by researchers use either single-cell or multi-cell pictures to detect leukemia cells, they frequently lack model generalization that perform better on heterogeneous datasets. They are also insufficient for deployment in real time. This study aims to develop generalized real-time system for detecting ALL cells from single and multi-cell microscopic blood smear images. The system utilizes three YOLO based state-of-the-art models: YOLO11, YOLOv8 and YOLOv5. The core novelty of this study lies in the creation of a unified dataset that integrates both single-cell and multi-cell microscopic blood smear images, this enables the model to learn generalized representations from diverse image contexts. Three datasets are merged to create the unified dataset, ALL-IDB1: multi- cell images, ALL-IDB2 & C-NMC-19: single-cell images. Image annotation and preprocessing are performed using Roboflow platform, while Google Colab is used for training and testing. These models are trained separately on individual datasets and the unified dataset.The performance of generalized YOLO models is assessed and contrasted against dataset-specific models using mAP@50 and recall metrics on the same set of unseen images from all three datasets.The experimental results indicate that generalized YOLOv8 model achieved notably high recall and competitive map@50, demonstrating strong adaptability and accuracy. These results highlight YOLOv8 as a promising solution for developing generalized model for leukemia cell detection.
- Open Access
- 24 March 2025
- Published by Asian Research Association in International Research Journal of Multidisciplinary Technovation
- p. 121-134
An Efficient System for Detection and Classification of Acute Lymphoblastic Leukemia Using Semi-Supervised Segmentation Technique
Acute lymphoblastic leukemia (ALL), sometimes referred to as hematopoietic cancer or blood cancer, is a group of cancers that impact lymphocytes, which are white blood cells. Improving patient outcomes and developing efficient treatment plans depend on early and precise blood cancer diagnosis. The lack of labelled data makes it difficult to segment lymphoblast cells from microscopic images. Our research aimed to achieve unsupervised approach for precise and accurate segmentation of blasted lymphocyte cells, thereby improving the overall performance of ALL detection and classification into its subtypes L1, L2 and L3. The proposed method employs k-means segmentation, where the parameter k is tuned, and optimal value is determined based on segmentation quality. For better performance, generated segments are evaluated against ground truth image based on Structural Similarity Index Measure (SSIM), Dice similarity coefficient (DSC) and Intersection over union (IoU). The algorithm iterates over different values of k, assesses the segmentation quality, and selects the segment with the highest evaluation score. Customized convolutional neural networks are employed for categorization. The data augmentation technique has been applied to expand the amount of training data in order to enhance model efficiency. The ALL-IDB dataset is used to assess the model's performance, and the experimental results showed that the suggested method can identify blasted cell subtypes with an overall accuracy of 99%. We succeeded in detecting acute lymphoblastic leukemia with 100% accuracy. Our proposed model not only enhances the accuracy significantly but also determines the optimal value of clusters (k) for more effective segmentation.
- 24 March 2025
- Published by Asian Research Association in International Research Journal of Multidisciplinary Technovation
- p. 121-134
Open AccessAn Efficient System for Detection and Classification of Acute Lymphoblastic Leukemia Using Semi-Supervised Segmentation Technique
Acute lymphoblastic leukemia (ALL), sometimes referred to as hematopoietic cancer or blood cancer, is a group of cancers that impact lymphocytes, which are white blood cells. Improving patient outcomes and developing efficient treatment plans depend on early and precise blood cancer diagnosis. The lack of labelled data makes it difficult to segment lymphoblast cells from microscopic images. Our research aimed to achieve unsupervised approach for precise and accurate segmentation of blasted lymphocyte cells, thereby improving the overall performance of ALL detection and classification into its subtypes L1, L2 and L3. The proposed method employs k-means segmentation, where the parameter k is tuned, and optimal value is determined based on segmentation quality. For better performance, generated segments are evaluated against ground truth image based on Structural Similarity Index Measure (SSIM), Dice similarity coefficient (DSC) and Intersection over union (IoU). The algorithm iterates over different values of k, assesses the segmentation quality, and selects the segment with the highest evaluation score. Customized convolutional neural networks are employed for categorization. The data augmentation technique has been applied to expand the amount of training data in order to enhance model efficiency. The ALL-IDB dataset is used to assess the model's performance, and the experimental results showed that the suggested method can identify blasted cell subtypes with an overall accuracy of 99%. We succeeded in detecting acute lymphoblastic leukemia with 100% accuracy. Our proposed model not only enhances the accuracy significantly but also determines the optimal value of clusters (k) for more effective segmentation.