XZXinbing Zhang

Xinbing Zhang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Xinbing Zhang has a total of 22 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Gamma suppression correlates with thalamic stimulation therapeutic response in intractable epilepsy

    by Zachary T. Sanger, Xinbing Zhang, Thomas Lisko, Hafsa Farooqi, Steffen Ventz, Sandipan Pati, Thomas R. Henry, David P. Darrow, Michael C. Park, Theoden I. Netoff, et al.

    Objective: In patients with drug‐resistant epilepsy who undergo anterior nucleus of the thalamus (ANT) deep brain stimulation (DBS), efficacy is assessed months after therapy initiation and clinicians have no guidance when choosing stimulation parameters due to the lack of real‐time biomarkers. Here, we identified acute and chronic suppression of slow gamma local field potential (LFP) oscillations (SGOs) (20–50 Hz) in the ANT as a novel electrophysiological biomarker correlated with therapeutic response. Methods: Participants enrolled in an ongoing prospective ANT‐DBS parameter optimization trial ( N = 11) were analyzed retrospectively for the effects of stimulation on ANT LFPs. One‐minute baseline and stimulation ANT LFPs were captured across follow‐up visits using a Medtronic Percept, testing different stimulation settings around the Stimulation of the Anterior Nucleus of the Thalamus in Epilepsy (SANTE) trial clinical setting (145 Hz, 90 μs) in the clinic. Aperiodic component detrended ANT LFP power spectral density responses during stimulation were compared against each baseline responses. Participants kept a seizure diary, where responders were those who achieved greater than a 50% seizure frequency reduction compared to their pre‐DBS seizure frequency. Results: In the seven participants exhibiting SGOs, six were responders. Progressive suppression (“gamma fade”) of SGOs under chronic stimulation correlated with long‐term seizure reduction in five of six responders. Acute stimulation in‐clinic with multiple settings suppressed SGOs in four of five responders, challenging fixed‐programming paradigms, with only one responder using the clinical gold standard parameters at the last follow‐up visit. Significance: These findings establish SGO suppression as a potential multiscale biomarker for responder identification, parameter titration, and therapeutic tracking for precise, biomarker‐guided intervention.


  • Open Access

    Rhythms in longitudinal thalamic recordings are linked to seizure risk

    by Xinbing Zhang, Zachary T. Sanger, Thomas Lisko, Steffen Ventz, Robert A. McGovern, Theoden I. Netoff

    Objective: Seizure unpredictability remains a major clinical challenge for people with epilepsy. Previous works have shown that seizure risk is associated with circadian and multi‐day cycles in both brain and physiological signals. However, it remains unclear whether neural activity from deep brain structures such as the anterior nucleus of the thalamus (ANT), the only U.S. Food and Drug Administration (FDA)–approved deep‐brain stimulation (DBS) target for treating medication‐resistant epilepsy, exhibits similar cyclic modulation related to seizures. This study aimed to assess whether long‐term local field potential (LFP) recordings from the ANT exhibit circadian and multi‐day cycles that are associated with seizures that could be used to support seizure forecasting in a retrospective approach. Methods: Seven participants implanted with the Medtronic Percept PC system for ANT‐DBS underwent continuous at‐home LFP recording of theta/alpha (4–12 Hz) and self‐reported seizure logs. Wavelet and Hilbert transforms were used to identify rhythmic cycles in LFPs. Circular statistics quantified seizure phase‐locking to LFP cycles and patterns estimated from seizure diaries. Gaussian process regression (GPR) models were trained using the instantaneous phase and amplitude of these cycles to forecast short‐term seizure risk. Results: A total of 7.37 years of at‐home LFP recordings were analyzed. All seven participants exhibited circadian and/or multi‐day cycles in their ANT LFPs, with seizures significantly phase‐locked to some of these cycles. Incorporating the instantaneous cycle amplitude improved seizure forecasting performance across all participants. Moreover, a substantial, although non‐significant, positive correlation between circadian cycle power and seizure frequency was found in most participants, suggesting an elevated seizure risk when circadian cycles are stronger. Significance: This study demonstrates that long‐term LFP recordings from the ANT reflect rhythmic brain activity linked to seizure risk, and that cycle amplitude provides complementary information about seizure risk than the phase alone.


  • Open Access

    Rhythms in Longitudinal Thalamic Recordings are Linked to Seizure Risk

    by Xinbing Zhang, Zachary Sanger, Thomas Lisko, Steffen Ventz, Robert A McGovern, Theoden I Netoff

    Objectives Seizure unpredictability remains a major clinical challenge for people with epilepsy. Previous works have shown that seizure risk is associated with circadian and multi-day cycles in both brain and physiological signals. However, it remains unclear whether neural activity from deep brain structures such as the anterior nucleus of the thalamus (ANT), the only FDA-approved deep-brain stimulation (DBS) target for treating medication-resistant epilepsy, exhibits similar cyclic modulation related to seizures. This study aimed to assess whether long-term local field potential (LFP) recordings from the ANT exhibit circadian and multi-day cycles that are associated with seizures that could be used to forecast seizure risk in a retrospective approach. Methods Seven participants implanted with the Medtronic Percept PC system for ANT-DBS underwent continuous at-home LFP recording of the theta/alpha (4-12 Hz) and self-reported seizure logs. Wavelet and Hilbert transforms were used to identify rhythmic cycles in LFPs. Circular statistics quantified seizure phase-locking to LFP cycles and patterns estimated from seizure diaries. Gaussian process regression (GPR) models were trained using the instantaneous phase and amplitude of these cycles to forecast short-term seizure risk. Results All participants exhibited circadian and multi-day cycles in their ANT LFPs, with seizures significantly phase-locked to some of these cycles. Seizure risk forecasting using LFP cycles achieved performance above chance (mean AUROC: 0.63 [0.57–0.69]). Incorporating the instantaneous cycle amplitude modestly improved prediction in some cases. Moreover, a substantial, though non-significant, positive correlation between circadian cycle power and seizure frequency was found in most participants, suggesting an elevated seizure risk when circadian cycles are stronger. Significance This study demonstrates that long-term LFP recordings from the ANT reflect rhythmic brain activity linked to seizure risk and may support seizure forecasting. Future studies should explore multi-modal approaches that incorporate both the phase and amplitude of cycles to improve prediction accuracy.

  • Open Access

    Slow Gamma Suppression Correlates with Therapeutic Response to Anterior Thalamic Deep Brain Stimulation in Intractable Epilepsy

    by Zachary T Sanger, Xinbing Zhang, Thomas Lisko, Hafsa Farooqi, Steffen Ventz, Sandipan Pati, Thomas Henry, David Darrow, Michael Park, Theoden I Netoff, et al.

    In drug-resistant epilepsy patients who undergo anterior thalamic deep brain stimulation (ANT-DBS), efficacy is assessed months after therapy initiation and clinicians have no guidance when choosing stimulation parameters due to the lack of real-time biomarkers. Here, we identified acute and chronic suppression of slow gamma oscillations (SGOs) (20–50Hz) in the ANT as a novel electrophysiological biomarker correlated with therapeutic response. Through analysis of an ongoing prospective ANT-DBS parameter optimization trial (N=11), 6/7 participants exhibiting SGOs were responders. Progressive suppression (“gamma fade”) of SGOs under chronic stimulation correlated with long-term seizure reduction in 5/6 responders. Acute stimulation in-clinic with multiple settings suppressed SGOs in 4/5 responders, challenging fixed-programming paradigms, with only one responder using the clinical gold standard parameters at the last follow-up visit. These findings establish SGO suppression as a potential multiscale biomarker for responder identification, parameter titration, and therapeutic tracking for precise, biomarker-guided intervention.


  • Open Access

    Anterior nucleus of thalamus deep brain stimulation for medication refractory epilepsy modulates theta and low-frequency gamma activity: a case study

    by Zachary T. Sanger, Xinbing Zhang, Ilo E. Leppik, Thomas Lisko, Theoden I. Netoff, Robert A. McGovern

    A 35-year-old gentleman with a traumatic brain injury was diagnosed with refractory epilepsy with electroencephalogram and imaging findings supporting a broad seizure onset pattern in bilateral frontotemporal regions. He therefore received a Medtronic Percept PC Deep Brain Stimulator (DBS) placed bilaterally in the anterior nucleus of the thalamus (ANT). While most refractory epilepsy patients’ stimulation parameters use the SANTE trial standard clinical settings of 145 Hz, 90 μs, with cycling 1-min stimulation on and 5 min stimulation off, this participant underwent 7 different stimulation parameter tests at home following testing in the clinic of 24 different stimulation parameters across 12 neurologist visits. This device allows for simultaneous stimulation of the ANT while recording the ANT local field potential (LFP) response under different stimulation parameters. Slepian multitaper analysis, modified Fitting Oscillations, and One Over F method for detrending the aperiodic component were performed to analyze neural oscillations in the frequency domain captured in the clinic. This participant was participating in a clinical study examining the effectiveness of nonstandard DBS settings to minimize broadband neural activity in the ANT. Statistically significant neuromodulatory suppression of gamma oscillations was observed in the clinic under multiple stimulation settings. We compared the ability of these research stimulation parameters to suppress at-home ANT neural activity against the standard clinical settings and examined the effects of both sets of parameters on LFP power nonstationarity. At home, theta/alpha LFP power suppression was statistically significantly reduced under the 125 Hz, 50 μs setting as opposed to the clinical setting of 145 Hz, 90 μs. The participant has achieved greater than 50% seizure reduction for over 1 year since the last neurology visit. Suppression of gamma in the clinic in the right hemisphere and suppression of theta at home in the left hemisphere show promise as quantitative feedback biomarkers for ANT-DBS. Understanding the local and network relationships of theta and slow gamma oscillations in the thalamus would further explain how these modulated oscillations may relate to the onset and propagation of seizures.