Yu-Jen Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yu-Jen Chen has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
Chin-Feng Chen
2 shared publicationsChih-Yuan Weng
1 shared publication- Chih-Yuan Weng
Air Force Institute of Technology
1 shared publication Hsin-Hsiu Ho
1 shared publication- Hsin-Hsiu Ho
Fire Protection Engineering, Worcester Polytechnic Institute, Worcester, USA
1 shared publication Min-Hao Sung
1 shared publication
Latest Publications
- 29 August 2025
- Published by Elsevier in Process Safety and Environmental Protection
- Vol. 202
Strategies for smoke control in tunnel fires: Approaches from numerical and experimental studies
- 29 August 2025
- Published by Elsevier in Process Safety and Environmental Protection
- Vol. 202
Strategies for smoke control in tunnel fires: Approaches from numerical and experimental studies
- 18 August 2025
- Published by Elsevier in Journal of Loss Prevention in the Process Industries
- Vol. 98
Experimental investigation of in-rack sprinkler parameters for ASRS warehouse protection
- 18 August 2025
- Published by Elsevier in Journal of Loss Prevention in the Process Industries
- Vol. 98
Experimental investigation of in-rack sprinkler parameters for ASRS warehouse protection
- Open Access
- 1 January 2025
- Published by SAGE Publications in Science Progress
- Vol. 108 (1)
Study of indoor parking lot planning for electric vehicles through fire dynamics simulation
The lack of clear regulations regarding the provision of electric vehicles parking lots, particularly in indoor parking lots, may result in inadequate fire protection and contingency planning during construction. This study investigated fire contingency planning for electric vehicle parking lots in large shopping mall, specifically scrutinizing the effects of charging pile locations, and was conducted through field research and computer simulations. Fire dynamic simulation model was utilized to simulate a fire in an indoor parking lot and investigate the impact of automatic sprinkler systems on the fire scene. The findings indicated that while automatic sprinkler cannot directly extinguish a fire, they can suppress the hazard parameters of the surrounding environment, alleviate the hazard area, and provide more time for responders or firefighters to rescue those affected.
- 1 January 2025
- Published by SAGE Publications in Science Progress
- Vol. 108 (1)
Open AccessStudy of indoor parking lot planning for electric vehicles through fire dynamics simulation
The lack of clear regulations regarding the provision of electric vehicles parking lots, particularly in indoor parking lots, may result in inadequate fire protection and contingency planning during construction. This study investigated fire contingency planning for electric vehicle parking lots in large shopping mall, specifically scrutinizing the effects of charging pile locations, and was conducted through field research and computer simulations. Fire dynamic simulation model was utilized to simulate a fire in an indoor parking lot and investigate the impact of automatic sprinkler systems on the fire scene. The findings indicated that while automatic sprinkler cannot directly extinguish a fire, they can suppress the hazard parameters of the surrounding environment, alleviate the hazard area, and provide more time for responders or firefighters to rescue those affected.