XXXingyuan Xiao

Xingyuan Xiao

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Xingyuan Xiao has a total of 50 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Recent advances in polysaccharide hydrogels for skin and urethra tissue repair

    by Wenwen Cheng, Xingyuan Xiao, Weikang Hu, Zijian Wang

    Polysaccharide hydrogels are constructed with natural and modified polysaccharides as the core building units. Due to their desirable biocompatibility, degradability, and bioactivity, polysaccharide hydrogels are highly promising biomaterials for promoting skin and urethra tissue repair. The abundant functional groups and glycan information within polysaccharide molecules enable the polysaccharide hydrogels not only to simulate the biophysical characteristics of extracellular matrix (ECM), but also to actively participate in a series of regeneration‐associated biological processes. Building on these features, polysaccharide hydrogels have thus evolved from passive ECM mimics into bioactive platforms that dynamically regulate the tissue repair microenvironment via glycan‐mediated biological interactions. Unlike conventional hydrogel reviews focusing primarily on material composition, this review proposes a function‐oriented framework linking polysaccharide hydrogel structural design, biological functions, and tissue regeneration requirements. We specifically analyze how polysaccharide hydrogels address shared challenges in skin and urethral repair, including infection‐prone environments, epithelial reconstruction, and fibrosis regulation. Finally, this review proposes a future development prospect, highlighting the rational design and clinical translation of polysaccharide hydrogels.

  • Non-transecting posteriorly augmented anastomotic ureteroplasty with lingual mucosal onlay grafts: 5-year multi-institutional experience in 52 cases

    by Kangxiang Xu, Chaoqi Liang, Xincheng Gao, Yuancheng Zhou, Xiaomin Han, Yujie Xu, Wang Wang, Shuaishuai Chai, Manshun Dong, Ruoyu Li, et al.

  • Open Access

    Association Between Video-Derived Digital Operative Metrics and GEARS Scores in Robotic Surgery and Development of an Exploratory Multivariable Model

    by Xingyuan Xiao, Yuanzhuo Du, Zhenyu Liu, Xuewei Zhu, Kun Yang, Bing Li

    Background: Robotic-assisted surgery has been increasingly adopted across surgical specialties, but objective and efficient assessment of robotic surgical skills remains challenging. The Global Evaluative Assessment of Robotic Skills (GEARS) is commonly used for expert-based evaluation; however, it requires manual review and may not fully capture detailed operative processes. This study aimed to investigate the associations between video-derived digital operative metrics and expert-derived GEARS scores and to conduct an exploratory multivariable analysis of metrics associated with GEARS scores. Methods: Data were collected from 42 surgeons who completed a standardized robotic surgery training program. On the final training day, anonymized animal-operation videos were evaluated by blinded experts using the GEARS scale. Surgical videos were processed to extract 43 digital operative metrics related to instrument visibility, spatial positioning, camera control, clutch use, switching use, and motion characteristics. GEARS scores and digital operative metrics were compared according to annual laparoscopic surgical volume, including dichotomized volume groups, specialty-based subgroups, and volume tertiles. Stepwise multiple linear regression was used as an exploratory variable-selection approach to identify video-derived metrics associated with expert-derived GEARS scores. Results: After false discovery rate correction, no significant differences in GEARS scores or digital operative metrics were observed across annual laparoscopic surgical volume groups, specialty subgroups, or volume tertiles. The final regression model retained three predictors: mean camera-use count per minute, minimum distance from the left-side center point, and maximum distance from the right-side center point. The model had an apparent in-sample R2 of 0.509 (F = 9.588; p < 0.001). This value describes model fit within the present sample and has not been corrected for optimism. Conclusions: Video-derived digital operative metrics, particularly those reflecting camera control and instrument spatial distribution, were associated with expert-derived GEARS scores and may provide complementary quantitative information for expert-based robotic surgical skill assessment.

  • Open Access

    Robot-assisted vesical neck h-shaped flap plasty for vesicourethral anastomotic stenosis: a case report

    by Xingyuan Xiao, Kuibiao Wang, Qiuxuan Yu, Hang Yin, Mengxin Lu, Xincheng Gao, Bing Li

    Background: Vesicourethral anastomotic stenosis (VUAS) is a challenging complication, occurring in 2%–7% of patients following radical prostatectomy. Endoscopic treatment fails in some patients, severely impairing their quality of life. Open reconstructive surgery is technically demanding with a long learning curve. Thus, to address a complication known as vesicourethral anastomotic stenosis following radical prostatectomy, we propose a new robot-assisted vesical neck H-shaped plasty. Case Description: A 57-year-old patient with prostate cancer developed vesicourethral anastomotic stenosis (with a stenosis segment length of 2 cm) 4 months after laparoscopic radical prostatectomy. Following short-term recurrence of the condition after three transurethral incisions for VUAS, the patient received robot-assisted vesical neck H-shaped plasty for posterior urethral reconstruction. The surgical technique primarily involves constructing an H-shaped bladder flap, tubularizing it to reconstruct a funnel-shaped posterior urethra, performing a tension-free anastomosis between the vesical neck and the posterior urethra, and constructing a retrocurvature structure of the urethra. Treatment success was defined by both anatomical and functional criteria, unobstructed passage of a 17 Fr cystoscope or a urinary flow rate >15 mL/s. The patient in this study achieved adequate early urinary patency and no related complications. Conclusions: Based on short-term follow-up, robot-assisted vesical neck H-shaped flap plasty is feasible for vesicourethral anastomotic stenosis, but long-term follow-up is needed for verification.

  • Open Access

    Advancing urological practice: the value of combined antegrade and retrograde ureterography for the management of complex ureteral strictures

    by Kangxiang Xu, Manshun Dong, Chaoqi Liang, Ruoyu Li, Qiuxuan Yu, Jin Liu, Hang Yin, Kuibiao Wang, Xincheng Gao, Yuancheng Zhou, et al.

    Background: Complex proximal and mid-ureteral strictures, caused by calculi, inflammation, fibrosis, or iatrogenic injury, can result in hydronephrosis and renal function loss. Traditional ureterography, when used alone, has limitations in accurately assessing stricture length and detecting multiple segments. We evaluated the diagnostic value of the combined antegrade and retrograde ureterography (CARU) technique in complex strictures, focusing on stricture length, location, and severity. Methods: This retrospective study collected data from 110 patients diagnosed with proximal and mid-ureteral strictures at our center between January 2023 and November 2025. All patients were evaluated with CARU 4 weeks prior to surgery and subsequently underwent lingual mucosal graft (LMG) ureteroplasty. A comparative analysis was performed to assess the correlation between the preoperative CARU assessment of stricture data and the intraoperative findings. Subgroup analyses were conducted according to stricture etiology and severity. Results: CARU demonstrated excellent agreement with intraoperative findings for stricture location (κ=0.93, PConclusions: CARU is a valuable tool for evaluating complex proximal and mid-ureteral strictures, with high accuracy in assessing stricture location and severity. It provides valuable reference for estimating stricture and graft lengths. It could serve as a useful preoperative imaging modality for patients with proximal and mid-ureteral strictures.

  • Top Cited Papers
    Open Access

    Defect engineering of zinc-based metal organic framework with enhanced ROS generation for antibacterial and wound healing applications

    by Wenwen Cheng, Wang Wang, Zhijun Zhou, Hang Yin, Ye Yang, Feng Xiao, Wenjie You, Zesheng Chen, Weikang Hu, Xingyuan Xiao, et al.

    Bacterial infection in chronic skin defect poses a global healthcare challenge, fueled by antibiotic overuse and bacterial resistance. Zinc-based metal-organic frameworks (Zn-MOFs) with pro-oxidative nanozyme-like activity and broad-spectrum antibacterial activity, complemented by their inherent biocompatibility, have emerged as a promising alternative to antibiotics. However, the translational applications of Zn-MOFs are limited by suboptimal enzyme-mimicking catalytic activity, inadequate biodistribution and target site accumulation. To overcome these limitations, this study establishes a strategy of oxygen vacancy (Ov)-based defect engineering combined with microneedle-mediated transdermal delivery. An Ov-rich Zn2+/H2BDC (Ov-ZBC) MOF is first synthesized by two-step reactions, and then immobilized into the tips of gelatin methacryloyl (GelMA) microneedles to obtain the double-layer GelMA/Ov-ZBC (GOZ) microneedles. Ov-ZBC MOFs demonstrate abundant Ov defects, which consequently led to a superior reactive oxygen species (ROS) production ability. Under visible light irradiation, GOZ microneedles inhibit bacterial survival and proliferation by producing ROS and releasing Zn2+. Additionally, they accelerate the healing of S. aureus-infected wounds through multimodal mechanisms, such as anti-inflammatory, M2 macrophage polarization, and promoting cell proliferation. In conclusion, this study not only develops an antibiotic-free theranostic platform, but also provides a proof-of-concept for modifying Zn-MOFs, thereby paving the way for their advanced biomedical applications.


  • Open Access

    Posteriorly Augmented Anastomotic Ureteroplasty with Lingual Mucosal Onlay Grafts: 8-year Multi-institutional Experience in 61 Cases

    by Yuancheng Zhou, Shuaishuai Chai, Kangxiang Xu, Xincheng Gao, Wang Wang, Manshun Dong, Ruoyu Li, Chaoqi Liang, Bing Li, Xingyuan Xiao


  • Open Access

    Robotic tubular pyeloureteroplasty using flap and lingual mucosal graft: a case report and literature review

    by Kangxiang Xu, Chaoqi Liang, Yuancheng Zhou, Shuaishuai Chai, Jianjun Fang, Xingyuan Xiao, Bing Li

    Case Report Robotic tubular pyeloureteroplasty using flap and lingual mucosal graft: a case report and literature review Kangxiang Xu, Chaoqi Liang, Yuancheng Zhou, Shuaishuai Chai, Jianjun Fang, Xingyuan Xiao, Bing Li

  • Open Access

    Group competition mechanism in surgical robot training: a randomized controlled trial

    by Huiqin Zhou, Liyuan Huang, Yuanzhuo Du, Jonathan Lio, Bin Luo, Xingyuan Xiao, Kun Yang

    Limited training equipment and instructors at training centers cannot fulfill the simultaneous training required of numerous trainees. Optimizing the training organization can improve the training efficiency and trainee performance to enhance the overall training effectiveness. This study aims to evaluate the effectiveness and feasibility of group competition mechanism under peer evaluation during robot training. A randomized controlled trial was conducted with 60 robotic-naive medical students, divided into two groups: independent training and team-based learning with a competitive element. Both groups performed Pick-and-Place (PP), Match-Board-2 (MB), and Thread-the-Rings-1 (TR) tasks on a dV-Trainer robot simulator. Training scores were automatically recorded to construct learning curves and calculate scoring efficiencies, which were compared between the two groups. Compared with the conventional training group, the group utilizing the group competition training format demonstrated significantly higher average operational scores, scoring efficiency, and learning curves (P < 0.05). In addition, the group competition mode demonstrates a higher performance in cultivating the trainees’ satisfactory operational habits (P < 0.001). Based on task-reporting strategies guided by peer evaluation, the group competition mechanism is a novel and effective model for improving robot simulator training. This method holds promise as an effective tool for the surgical education of practicing surgeons and clinical medical students.


  • Open Access

    Application of omental covering technique in robot-assisted lingual mucosa graft ureteroplasty

    by Yuancheng Zhou, Manshun Dong, Shuaishuai Chai, Kangxiang Xu, Ruoyu Li, Chaoqi Liang, Xingyuan Xiao, Bing Li

    Background: Omentum has a wide application value in ureteroplasty, however, some specific situations limit its clinical application. Therefore, we modified the application method of omentum and proposed a new method named omental covering (OC) technique. This study aims to systematically evaluate the safety and efficacy of OC technique in robot-assisted lingual mucosa graft ureteroplasty (RA-LMGU). Methods: We conducted a retrospective analysis of data from 79 patients who underwent RA-LMGU between June 2021 and October 2024 at two hospitals. Patients were divided into two groups according to the method of omental application: the omental wrapping (OW) group and the OC group. Perioperative and follow-up data were collected. Results: A total of 79 patients were included, with 24 in the OW group and 55 in the OC group. The median ureteral stricture length was 4.3 [interquartile range (IQR), 3.7, 6.0] cm in the OW group and 3.0 (IQR, 2.1, 4.0) cm in the OC group (PConclusions: These short-term follow-up results demonstrated that the OC technique is also safe and effective in ureteral repair and reconstruction using lingual mucosa graft and it can reduce postoperative stay.