Weicheng Yan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Weicheng Yan has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
- Ming Yuchi
Huazhong University of Science and Technology
4 shared publications - Mingyue Ding
School of Life Science and Technology, Advanced Bio-Medical Imaging Facility, Huazhong University of Science and Technology, Wuhan, China
4 shared publications - Wu Qiu
Huazhong University of Science and Technology
4 shared publications Xiaolu Zeng
4 shared publicationsHongrui Tan
3 shared publications- Zesong Wang
School of Life Science and Technology, Advanced Bio-Medical Imaging Facility, Huazhong University of Science and Technology, Wuhan, China
3 shared publications
Latest Publications
- 14 November 2026
- Published by Elsevier in Ultrasonics
- Vol. 171
Speed-of-sound validation in ring array ultrasound computed tomography using transmission-mode tissue-mimicking phantoms
- 14 November 2026
- Published by Elsevier in Ultrasonics
- Vol. 171
Speed-of-sound validation in ring array ultrasound computed tomography using transmission-mode tissue-mimicking phantoms
- 14 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Reviews in Biomedical Engineering
- Vol. PP (19373333) , 1-18
Review of Current Advances in Ultrasound Computed Tomography for Medical Imaging
Ultrasound Computed Tomography (USCT) represents a paradigm shift in medical imaging, offering quantitative, high-resolution tissue characterization for diverse anatomical regions including breast, musculoskeletal system, brain, and lungs. By capturing the full ultrasonic wavefield through dedicated transducer arrays, USCT enables reconstruction of intrinsic tissue properties such as sound speed, attenuation, and acoustic impedance. Unlike conventional ultrasound, USCT provides three fundamental advantages: full-angle tomographic reconstruction, quantitative multi-parameter imaging capabilities, and operator-independent standardized acquisition—all while maintaining ultrasound’s inherent safety and cost-effectiveness. While clinical adoption is still evolving, the technology has achieved significant milestones with several commercially available systems receiving regulatory approval for breast imaging. This review synthesizes recent advances across five critical domains: system hardware design, reflection imaging, quantitative multi-parameter reconstruction (particularly through full-waveform inversion), precision calibration methodologies, and expanding clinical applications. Additionally, we have offered a comprehensive review of the application of deep learning-related technologies in USCT. By comprehensively analyzing current challenges and emerging trends, this work provides researchers and clinicians with an essential reference for understanding the state of the art and identifying pivotal pathways toward widespread clinical implementation of USCT technology.
- 14 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Reviews in Biomedical Engineering
- Vol. PP (19373333) , 1-18
Review of Current Advances in Ultrasound Computed Tomography for Medical Imaging
Ultrasound Computed Tomography (USCT) represents a paradigm shift in medical imaging, offering quantitative, high-resolution tissue characterization for diverse anatomical regions including breast, musculoskeletal system, brain, and lungs. By capturing the full ultrasonic wavefield through dedicated transducer arrays, USCT enables reconstruction of intrinsic tissue properties such as sound speed, attenuation, and acoustic impedance. Unlike conventional ultrasound, USCT provides three fundamental advantages: full-angle tomographic reconstruction, quantitative multi-parameter imaging capabilities, and operator-independent standardized acquisition—all while maintaining ultrasound’s inherent safety and cost-effectiveness. While clinical adoption is still evolving, the technology has achieved significant milestones with several commercially available systems receiving regulatory approval for breast imaging. This review synthesizes recent advances across five critical domains: system hardware design, reflection imaging, quantitative multi-parameter reconstruction (particularly through full-waveform inversion), precision calibration methodologies, and expanding clinical applications. Additionally, we have offered a comprehensive review of the application of deep learning-related technologies in USCT. By comprehensively analyzing current challenges and emerging trends, this work provides researchers and clinicians with an essential reference for understanding the state of the art and identifying pivotal pathways toward widespread clinical implementation of USCT technology.
- Open Access
- 3 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in TechRxiv
Review of Current Advances in Ultrasound Computed Tomography for Medical Imaging
Ultrasound Computed Tomography (USCT) represents a paradigm shift in medical imaging, offering quantitative, high-resolution tissue characterization for diverse anatomical regions including breast, musculoskeletal system, brain, and lungs. By capturing the full ultrasonic wavefield through dedicated transducer arrays, USCT enables reconstruction of intrinsic tissue properties such as sound speed, attenuation, and acoustic impedance. Unlike conventional ultrasound, USCT provides three fundamental advantages: full-angle tomographic reconstruction, quantitative multi-parameter imaging capabilities, and operatorindependent standardized acquisition-all while maintaining ultrasound's inherent safety and cost-effectiveness. While clinical adoption is still evolving, the technology has achieved significant milestones with several commercially available systems receiving regulatory approval for breast imaging. This review synthesizes recent advances across five critical domains: system hardware design, structural imaging, quantitative multi-parameter reconstruction (particularly through full-waveform inversion), precision calibration methodologies, and expanding clinical applications. Additionally, we examine the transformative integration of deep learning techniques throughout the USCT pipeline. By comprehensively analyzing current challenges and emerging trends, this work provides researchers and clinicians with an essential reference for understanding the state of the art and identifying pivotal pathways toward widespread clinical implementation of USCT technology.
- 3 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in TechRxiv
Open AccessReview of Current Advances in Ultrasound Computed Tomography for Medical Imaging
Ultrasound Computed Tomography (USCT) represents a paradigm shift in medical imaging, offering quantitative, high-resolution tissue characterization for diverse anatomical regions including breast, musculoskeletal system, brain, and lungs. By capturing the full ultrasonic wavefield through dedicated transducer arrays, USCT enables reconstruction of intrinsic tissue properties such as sound speed, attenuation, and acoustic impedance. Unlike conventional ultrasound, USCT provides three fundamental advantages: full-angle tomographic reconstruction, quantitative multi-parameter imaging capabilities, and operatorindependent standardized acquisition-all while maintaining ultrasound's inherent safety and cost-effectiveness. While clinical adoption is still evolving, the technology has achieved significant milestones with several commercially available systems receiving regulatory approval for breast imaging. This review synthesizes recent advances across five critical domains: system hardware design, structural imaging, quantitative multi-parameter reconstruction (particularly through full-waveform inversion), precision calibration methodologies, and expanding clinical applications. Additionally, we examine the transformative integration of deep learning techniques throughout the USCT pipeline. By comprehensively analyzing current challenges and emerging trends, this work provides researchers and clinicians with an essential reference for understanding the state of the art and identifying pivotal pathways toward widespread clinical implementation of USCT technology.
- 26 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-14
Untrained Neural Network-Based Full-Waveform Inversion for Breast Sound Speed Imaging in Ultrasound Computed Tomography
Quantitative imaging represents a pivotal advantage of ultrasound computed tomography (USCT), significantly distinguishing it from conventional ultrasound imaging techniques. Especially, Sound speed imaging in USTC has been documented to play a crucial role in the clinical diagnosis of breast cancer. Due to the high demand for resolution in medical applications, full-waveform inversion (FWI) has gradually become a research hotspot compared to time-of-flight methods due to its potential for high-resolution imaging. However, the main challenge of FWI is its sensitivity to initial values due to its inherent non-convex and non-linear properties. An inappropriate initial value can lead it to fall into a local optimal solution, which ultimately produces a sound speed image with no physiological significance, a phenomenon also known as ’cycle-skipping’, severely limiting the application of the method to USCT. In this paper, we propose a method based on an untrained neural network (UNN), which is embedded into the framework of the conventional iteration-based FWI as a sound speed image generator. The implicit regularization provided by this method can effectively alleviate the ill-posed nature of FWI. Significantly, the proposed UNN method allows for unsupervised training, which is essential in medical imaging due to the lack of ground truth paired data. Evaluations on numerical simulations, phantom experiments, and in-vivo breast experiments demonstrate the effectiveness of the proposed UNN in enhancing imaging robustness and reducing image artifacts compared to the traditional FWI. To the best of our knowledge, this study represents the first to investigate the UNN based FWI for USCT breast sound speed imaging and validate it on in-vivo breast experiments.
- 26 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-14
Untrained Neural Network-Based Full-Waveform Inversion for Breast Sound Speed Imaging in Ultrasound Computed Tomography
Quantitative imaging represents a pivotal advantage of ultrasound computed tomography (USCT), significantly distinguishing it from conventional ultrasound imaging techniques. Especially, Sound speed imaging in USTC has been documented to play a crucial role in the clinical diagnosis of breast cancer. Due to the high demand for resolution in medical applications, full-waveform inversion (FWI) has gradually become a research hotspot compared to time-of-flight methods due to its potential for high-resolution imaging. However, the main challenge of FWI is its sensitivity to initial values due to its inherent non-convex and non-linear properties. An inappropriate initial value can lead it to fall into a local optimal solution, which ultimately produces a sound speed image with no physiological significance, a phenomenon also known as ’cycle-skipping’, severely limiting the application of the method to USCT. In this paper, we propose a method based on an untrained neural network (UNN), which is embedded into the framework of the conventional iteration-based FWI as a sound speed image generator. The implicit regularization provided by this method can effectively alleviate the ill-posed nature of FWI. Significantly, the proposed UNN method allows for unsupervised training, which is essential in medical imaging due to the lack of ground truth paired data. Evaluations on numerical simulations, phantom experiments, and in-vivo breast experiments demonstrate the effectiveness of the proposed UNN in enhancing imaging robustness and reducing image artifacts compared to the traditional FWI. To the best of our knowledge, this study represents the first to investigate the UNN based FWI for USCT breast sound speed imaging and validate it on in-vivo breast experiments.