SMSidharth Misra

Sidharth Misra

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Sidharth Misra has a total of 12 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • The association between gut microbiome and aortic aneurysm: a review article

    by Sidharth Misra, Zainab Yusufali Motiwala, Aditya Puniyani, Shobhit Kumar, Devika Nair, Bratish Poddar, Fatima Nadeem, Mohammed Idhrees

    Aortic aneurysm is influenced by traditional risk factors such as atherosclerosis, hypertension, and diabetes. Latest evidence states that the gut microbiome may play a crucial role in its pathogenesis. This review aims to explore the relationship between the gut microbiome and aortic aneurysm. We conducted a comprehensive literature review using PubMed, Embase, and Google Scholar to understand the association between aortic aneurysm and the gut microbiome. Relevant studies were evaluated and critically analyzed to narratively summarize existing knowledge and highlight research gaps. The analysis revealed that gut dysbiosis affects systemic inflammation and immune response. This in turn contributes to the degeneration of the vessel wall and aneurysm development. Bacterial metabolites, such as short-chain fatty acids (SCFAs), were found to influence inflammatory pathways, while microbial translocation exacerbates oxidative stress. Understanding the gut microbiome-aortic aneurysm axis can lead to the development of innovative prevention and therapeutic strategies focused on aortic aneurysm formation.

  • Top Cited Papers

    Telesurgery: current status and strategies for latency reduction

    by Zainab Yusufali Motiwala, Arusha Desai, Rahul Bisht, Saloni Lathkar, Sidharth Misra, Danny Darlington Carbin

    Telesurgery is a rapidly evolving field in robotic assisted surgery that allows surgeons to operate on patients remotely with the help of robotic systems. This has allowed increased access to specialized care reducing geographic barriers and improving overall surgical outcomes in remote locations. An important challenge that hinders its widespread adoption is latency period which is primarily a delay that exists in data transmission between the surgeon and the robotic system. It is essential to determine strategies that can reduce it to ensure greater precision, dexterity, and patient safety. A literature review was conducted using PubMed, Embase, Google Scholar, and Cochrane Library. After screening the articles for relevance, data were synthesized to present a narrative review on the current challenges and emerging solutions in latency reduction. Those articles were included that discussed telesurgery with latency periods, network infrastructure, AI driven latency compensation, and cybersecurity. After removing 8 duplicates, a total of 238 articles were identified in the literature search out of which 175 articles were excluded after title and abstract screening done by two independent reviewers. 63 full text articles were assessed for eligibility. Latency period greatly impacts telesurgical performance with an ideal value being less than 200 ms. This threshold is essential for effective surgical precision, and safety. The adoption of ultra-low latency 6G wireless networks, quantum computing, and artificial intelligence can enhance telesurgical performance. Ethical, legal, and cybersecurity challenges must be addressed for widespread adoption of telesurgery. Latency in telesurgery arise due to a multitude of factors, including network infrastructure, geographic barriers, cybersecurity protocols, hardware, and software limitations. AI-based algorithms, edge computing, advancements in 5G technology, along with optimum haptic feedback mechanisms are promising solutions in reducing latency.


  • Robotics versus open surgery: the impact on cytokine release and patient outcomes

    by Sidharth Misra, Zainab Yusufali Motiwala, Aditya Puniyani, Laaiba Shamsi, Fatima Nadeem, Danny Darlington Carbin

    Surgical techniques have witnessed a significant evolution with the advent of robotic surgery. The impact of robotic surgery on the body’s immune system, specifically its role in causing cytokine storm has gained interest. The present narrative review explores the association between robotic surgery and cytokine release in the body and attempts to contrast it with open surgical technique consequently, highlighting the impact on patient outcomes. A literature review was conducted using PubMed, Embase, Google Scholar, Web of Science and Cochrane databases. Screening was done using the keywords “Robotic Surgery,” “Robot Assisted Surgery,” “Conventional Surgery,” “Cytokine,” “Tissue Injury,” “Inflammatory Response,” and “IL-6.” A total of 5379 articles were identified in the literature search out of which 5172 article records were excluded after the title and abstract screening that was done by two independent reviewers. 207 full text articles were assessed for eligibility and 154 were excluded. Finally, 53 articles were used as a core for this review article. Robotic surgery has been found to have a lower cytokine response and improved clinical outcomes in comparison to the open approach. It is crucial to consider the confounding factors when evaluating the postoperative outcomes that could affect the relationship between the surgical approach, cytokine release and clinical outcomes.