Hongzhi Mao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Hongzhi Mao has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Chengran Fang
College of Civil Engineering, Zhejiang University of Technology, Hangzhou, 310023, China
2 shared publications - Haifeng Zhuang
Key Laboratory of Recycling and Eco-treatment of Waste Biomass of Zhejiang Province, Zhejiang University of Science and Technology, Hangzhou, China
2 shared publications Angelo Zarrella
1 shared publication- Binhui Chen
Department of Orthopaedic Surgery, Sir Run Run Shaw Hospital Affiliated to Medical College of Zhejiang University, Hangzhou 310016, Zhejiang, China
1 shared publication - Chongzheng Li
School of Environmental Science and Engineering, Huazhong University of Science and Technology, Wuhan 430074, China
1 shared publication - Fusong Wang
School of Safety Science and Emergency Management, Wuhan University of Technology, Wuhan 430070, China
1 shared publication
Latest Publications
- Open Access
A Precision Measurement Method for Rooftop Photovoltaic Capacity Using Drone and Publicly Available Imagery
Against the global backdrop of energy transition, the precise assessment of urban rooftop photovoltaic (PV) system capacity is recognized as crucial for optimizing the energy structure and enhancing the sustainable utilization efficiency of spatial resources. Publicly available aerial imagery is characterized by non-orthorectified issues; direct utilization is known to lead to geometric distortions in rooftop PV and errors in capacity prediction. To address this, a dual-optimization framework is proposed in this study, integrating monocular vision-based 3D reconstruction with a lightweight linear model. Leveraging the orthogonal characteristics of building structures, camera self-calibration and 3D reconstruction are achieved through geometric constraints imposed by vanishing points. Scale distortion is suppressed via the incorporation of a multi-dimensional geometric constraint error control strategy. Concurrently, a linear capacity-area model is constructed, thereby simplifying the complexity inherent in traditional multi-parameter fitting. Utilizing drone oblique photography and Google Earth public imagery, 3D reconstruction was performed for 20 PV-equipped buildings in Wuhan City. Two buildings possessing high-precision field survey data were selected as typical experimental subjects for validation. The results demonstrate that the 3D reconstruction method reduced the mean absolute percentage error (MAPE)—used here as an estimator of measurement uncertainty—of PV area identification from 10.58% (achieved by the 2D method) to 3.47%, while the coefficient of determination (R2) for the capacity model reached 0.9548. These results suggest that this methodology can provide effective technical support for low-cost, high-precision urban rooftop PV resource surveys. It has the potential to significantly enhance the reliability of energy planning data, thereby contributing to the efficient development of urban spatial resources and the achievement of sustainable energy transition goals.
Open AccessA Precision Measurement Method for Rooftop Photovoltaic Capacity Using Drone and Publicly Available Imagery
Against the global backdrop of energy transition, the precise assessment of urban rooftop photovoltaic (PV) system capacity is recognized as crucial for optimizing the energy structure and enhancing the sustainable utilization efficiency of spatial resources. Publicly available aerial imagery is characterized by non-orthorectified issues; direct utilization is known to lead to geometric distortions in rooftop PV and errors in capacity prediction. To address this, a dual-optimization framework is proposed in this study, integrating monocular vision-based 3D reconstruction with a lightweight linear model. Leveraging the orthogonal characteristics of building structures, camera self-calibration and 3D reconstruction are achieved through geometric constraints imposed by vanishing points. Scale distortion is suppressed via the incorporation of a multi-dimensional geometric constraint error control strategy. Concurrently, a linear capacity-area model is constructed, thereby simplifying the complexity inherent in traditional multi-parameter fitting. Utilizing drone oblique photography and Google Earth public imagery, 3D reconstruction was performed for 20 PV-equipped buildings in Wuhan City. Two buildings possessing high-precision field survey data were selected as typical experimental subjects for validation. The results demonstrate that the 3D reconstruction method reduced the mean absolute percentage error (MAPE)—used here as an estimator of measurement uncertainty—of PV area identification from 10.58% (achieved by the 2D method) to 3.47%, while the coefficient of determination (R2) for the capacity model reached 0.9548. These results suggest that this methodology can provide effective technical support for low-cost, high-precision urban rooftop PV resource surveys. It has the potential to significantly enhance the reliability of energy planning data, thereby contributing to the efficient development of urban spatial resources and the achievement of sustainable energy transition goals.
- 29 March 2025
- Published by Elsevier in Renewable Energy
- Vol. 247
A method on mapping the distribution of photovoltaic power stations in complex terrain regions
- 29 March 2025
- Published by Elsevier in Renewable Energy
- Vol. 247
A method on mapping the distribution of photovoltaic power stations in complex terrain regions
- 29 May 2020
- Published by Springer Nature in Bulletin of Environmental Contamination and Toxicology
- Vol. 105 (1) , 36-40
Antibiotics in Leachates from Landfills in Northern Zhejiang Province, China
The concentrations and distributions of five sulfonamide, three tetracycline, and two macrolide antibiotics in leachates from three landfill sites in northern Zhejiang Province, China, were determined by solid-phase extraction and ultra-high performance liquid chromatography mass spectrometry. Most of the antibiotics were detected in the leachate samples. The concentrations and distributions of the antibiotics in leachates of different ages were very different. The total sulfonamide, tetracycline, and macrolide concentrations in the leachates ranged from not detected to 1.57 × 103, not detected to 5.19 × 103, and 7.30 to 5.42 × 102 ng/L, respectively. The total concentrations of detectable antibiotics were higher in fresh leachates than aged and middle-aged leachates. Higher TC-group concentrations were found in the leachates than have been found in previously published studies of landfill leachates in China. The results improve our understanding of and ability to manage antibiotic residues in landfills.
- 29 May 2020
- Published by Springer Nature in Bulletin of Environmental Contamination and Toxicology
- Vol. 105 (1) , 36-40
Antibiotics in Leachates from Landfills in Northern Zhejiang Province, China
The concentrations and distributions of five sulfonamide, three tetracycline, and two macrolide antibiotics in leachates from three landfill sites in northern Zhejiang Province, China, were determined by solid-phase extraction and ultra-high performance liquid chromatography mass spectrometry. Most of the antibiotics were detected in the leachate samples. The concentrations and distributions of the antibiotics in leachates of different ages were very different. The total sulfonamide, tetracycline, and macrolide concentrations in the leachates ranged from not detected to 1.57 × 103, not detected to 5.19 × 103, and 7.30 to 5.42 × 102 ng/L, respectively. The total concentrations of detectable antibiotics were higher in fresh leachates than aged and middle-aged leachates. Higher TC-group concentrations were found in the leachates than have been found in previously published studies of landfill leachates in China. The results improve our understanding of and ability to manage antibiotic residues in landfills.
- 1 January 2020
- Published by Elsevier in Chinese Journal of Chemical Engineering
- Vol. 28 (1) , 249-253
Transformation of phthalic acid diesters in an anaerobic/anoxic/oxic leachate treatment process
- 1 January 2020
- Published by Elsevier in Chinese Journal of Chemical Engineering
- Vol. 28 (1) , 249-253
Transformation of phthalic acid diesters in an anaerobic/anoxic/oxic leachate treatment process