Tadashi Kondo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Tadashi Kondo has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Akira Yoneda
Department of Earth and Space Science, Osaka University 3 , Machikaneyama-cho 1-1, Toyonaka, Osaka 5600043
1 shared publication - Hidenori Terasaki
Department of Earth Sciences Okayama University Okayama Japan
1 shared publication Hiroyuki Kamina
Department of Earth Sciences, Okayama University 1 , Tsushimanaka 3-1-1, Kita-ku, Okayama 7008530
1 shared publicationKo Morioka
Department of Earth Sciences, Okayama University 1 , Tsushimanaka 3-1-1, Kita-ku, Okayama 7008530
1 shared publication- Moe Sakurai
Department of Earth Sciences, Okayama University 1 , Tsushimanaka 3-1-1, Kita-ku, Okayama 7008530
1 shared publication - Naohisa Hirao
Japan Synchrotron Radiation Research Institute
1 shared publication
Latest Publications
- 1 March 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (3)
Development of density measurement at high pressure and high temperature using the x-ray absorption method combined with laser-heated diamond anvil cell
The densities of liquid materials at high pressures and high temperatures are important information to understand the elastic behavior of liquids at extreme conditions, which is closely related to the formation and evolution processes of the Earth and planetary interiors. The x-ray absorption method is an effective method to measure the density of non-crystalline materials at high pressures. However, the temperature condition of the x-ray absorption method using a diamond anvil cell (DAC) has been limited to 720 K to date. To significantly expand the measurable temperature condition of this method, in this study, we developed a density measurement technique using the x-ray absorption method in combination with a laser-heated DAC. The density of solid Ni was measured up to 26 GPa and 1800 K using the x-ray absorption method and evaluated by comparison with the density obtained from the x-ray diffraction. The density of solid Ni with a thickness >17 μm was determined with an accuracy of 0.01%–2.2% (0.001–0.20 g/cm3) and a precision of 0.8%–1.8% (0.07–0.16 g/cm3) in the x-ray absorption method. The density of liquid Ni was also determined to be 8.70 ± 0.15–8.98 ± 0.38 g/cm3 at 16–23 GPa and 2230–2480 K. Consequently, the temperature limit of the x-ray absorption method can be expanded from 720 to 2480 K by combining it with a laser-heated DAC in this study.
- 1 March 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (3)
Development of density measurement at high pressure and high temperature using the x-ray absorption method combined with laser-heated diamond anvil cell
The densities of liquid materials at high pressures and high temperatures are important information to understand the elastic behavior of liquids at extreme conditions, which is closely related to the formation and evolution processes of the Earth and planetary interiors. The x-ray absorption method is an effective method to measure the density of non-crystalline materials at high pressures. However, the temperature condition of the x-ray absorption method using a diamond anvil cell (DAC) has been limited to 720 K to date. To significantly expand the measurable temperature condition of this method, in this study, we developed a density measurement technique using the x-ray absorption method in combination with a laser-heated DAC. The density of solid Ni was measured up to 26 GPa and 1800 K using the x-ray absorption method and evaluated by comparison with the density obtained from the x-ray diffraction. The density of solid Ni with a thickness >17 μm was determined with an accuracy of 0.01%–2.2% (0.001–0.20 g/cm3) and a precision of 0.8%–1.8% (0.07–0.16 g/cm3) in the x-ray absorption method. The density of liquid Ni was also determined to be 8.70 ± 0.15–8.98 ± 0.38 g/cm3 at 16–23 GPa and 2230–2480 K. Consequently, the temperature limit of the x-ray absorption method can be expanded from 720 to 2480 K by combining it with a laser-heated DAC in this study.