Khadidja Delimi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Khadidja Delimi has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Marcos Antonio Martínez Segura
Universidad Politécnica de Cartagena
2 shared publications - Oussama Jabrane
Laboratory of Geoheritage, Geoenvironment, Mining and Water Exploration, Faculty of Sciences, Mohammed 1st University, Oujda 60000, Morocco
2 shared publications - Pedro Martínez-Pagán
Department of Mining and Civil Engineering, Universidad Politécnica de Cartagena, 30203 Cartagena, Spain
2 shared publications - Ximena Capa-Camacho
Sustainable Use, Management and Reclamation of Soil and Water Research Group, Department of Agricultural Engineering Universidad Politécnica de Cartagena Cartagena Spain
2 shared publications - Marco David Vásconez Maza
British Geological Survey Keyworth Nottinghamshire UK
1 shared publication - Mimoun Chourak
Laboratory of Applied Sciences Research, National School of Applied Sciences of Oujda, Mohammed 1st University, Oujda 60000, Morocco
1 shared publication
Latest Publications
- Open Access
- 30 April 2026
- Published by Wiley in Vadose Zone Journal
- Vol. 25 (3)
Assessment of soil slurry saturation and slurry infiltration in pig slurry storage ponds using electrical resistivity tomography
Effective management of pig slurry in semi‐arid settings is critical to protect soils and aquifers. This study integrates multi‐profile electrical resistivity tomography (ERT) compiled into stitched 3D volumes with a calibration based on modified Archie's law derived from laboratory resistivity–moisture tests to obtain semi‐quantitative soil slurry saturation ( defined here as the fraction of connected pore space filled by pig slurry), beneath three active storage ponds in southeastern Spain, developed on silty clay (pond 1), sandy loam (pond 2), and silt loam (pond 3). Twenty dipole–dipole ERT profiles were inverted in 2D using a smoothness‐constrained (L2) inversion, and the resulting 2D models were stitched into 3D volumes for visualization and interpretation. Nine near‐pond soil cores were analyzed to determine texture‐specific porosity and to build calibration curves by incrementally wetting samples with pig slurry and normalizing resistivity to 25°C. In the modified Archie workflow, the cementation exponent ( m ) was selected per pond by minimizing cross‐validated misfit within literature bounds, while the saturation exponent ( n ) and the reference resistivity at full saturation ( were obtained from log–log regressions; pore‐fluid resistivity () was measured on the pig slurry. Calibrated models indicate a textural control on infiltration: silty clay shows shallow influence with declining below ∼3 m; sandy loam exhibits deeper and laterally extensive percolation to ∼4.5 m; silt loam is intermediate, maintaining elevated to ∼4–5 m. Across textures, resistivity increases sharply once falls below the laboratory breakpoint thresholds ≈ 0.37, 0.48, and 0.28 for ponds 1–3, respectively (see Section 3.2), indicating a loss of continuous conductive pathways. These texture‐specific thresholds were determined from laboratory resistivity–moisture curves as knee points marking the onset of an abrupt resistivity increase at low moisture and were converted from gravimetric moisture content to using Equation (5). Because bulk resistivity depends on saturation and pore‐fluid properties and m was fixed at its pond‐level calibrated value, maps are reported as semi‐quantitative. The Archie‐based approach offers a practical, non‐invasive tool to locate likely leakage pathways and to prioritize targeted verification for risk management of slurry ponds.
- 30 April 2026
- Published by Wiley in Vadose Zone Journal
- Vol. 25 (3)
Open AccessAssessment of soil slurry saturation and slurry infiltration in pig slurry storage ponds using electrical resistivity tomography
Effective management of pig slurry in semi‐arid settings is critical to protect soils and aquifers. This study integrates multi‐profile electrical resistivity tomography (ERT) compiled into stitched 3D volumes with a calibration based on modified Archie's law derived from laboratory resistivity–moisture tests to obtain semi‐quantitative soil slurry saturation ( defined here as the fraction of connected pore space filled by pig slurry), beneath three active storage ponds in southeastern Spain, developed on silty clay (pond 1), sandy loam (pond 2), and silt loam (pond 3). Twenty dipole–dipole ERT profiles were inverted in 2D using a smoothness‐constrained (L2) inversion, and the resulting 2D models were stitched into 3D volumes for visualization and interpretation. Nine near‐pond soil cores were analyzed to determine texture‐specific porosity and to build calibration curves by incrementally wetting samples with pig slurry and normalizing resistivity to 25°C. In the modified Archie workflow, the cementation exponent ( m ) was selected per pond by minimizing cross‐validated misfit within literature bounds, while the saturation exponent ( n ) and the reference resistivity at full saturation ( were obtained from log–log regressions; pore‐fluid resistivity () was measured on the pig slurry. Calibrated models indicate a textural control on infiltration: silty clay shows shallow influence with declining below ∼3 m; sandy loam exhibits deeper and laterally extensive percolation to ∼4.5 m; silt loam is intermediate, maintaining elevated to ∼4–5 m. Across textures, resistivity increases sharply once falls below the laboratory breakpoint thresholds ≈ 0.37, 0.48, and 0.28 for ponds 1–3, respectively (see Section 3.2), indicating a loss of continuous conductive pathways. These texture‐specific thresholds were determined from laboratory resistivity–moisture curves as knee points marking the onset of an abrupt resistivity increase at low moisture and were converted from gravimetric moisture content to using Equation (5). Because bulk resistivity depends on saturation and pore‐fluid properties and m was fixed at its pond‐level calibrated value, maps are reported as semi‐quantitative. The Archie‐based approach offers a practical, non‐invasive tool to locate likely leakage pathways and to prioritize targeted verification for risk management of slurry ponds.
- Open Access
- 1 April 2025
- Published by MDPI AG in Geosciences
- Vol. 15 (4) , 127
A Comparison of Array Configurations in Python-Based Software for ERT Data in Shallow Hazard Detection
Electrical Resistivity Tomography (ERT) is a widely used geophysical technique for imaging subsurface resistivity variations, providing critical insights for geological engineering and hazard assessment applications. While open-source inversion tools such as BERT and PyGIMLi offer accessible solutions for geoelectrical modeling, their comparative performance across different electrode configurations and noise conditions remains underexplored. This study evaluates the effectiveness of these software packages in reconstructing subsurface anomalies related to cavity detection and landslide assessment. Four commonly used electrode configurations—dipole–dipole, Schlumberger, Wenner-Alpha, and Wenner-Beta—were tested on two synthetic models designed to simulate real geological conditions: one representing cavity detection and the other simulating a landslide scenario. Inversions were conducted under both ideal conditions and with synthetic noise to assess their robustness against measurement uncertainties. Results indicate that while all configurations successfully identified major subsurface features, the dipole–dipole array provided the highest resolution for detecting small-scale anomalies. BERT demonstrated superior accuracy under ideal conditions, while PyGIMLi showed consistent performance across multiple configurations, particularly in resolving smaller features under noisy conditions. These findings emphasize the importance of selecting appropriate electrode configurations to enhance imaging accuracy and ensure reliable geo-electrical data interpretation. This study highlights the robustness of open-source geophysical software for subsurface investigations and provides practical insights into optimizing geoelectrical survey configurations for shallow hazard detection.
- 1 April 2025
- Published by MDPI AG in Geosciences
- Vol. 15 (4) , 127
Open AccessA Comparison of Array Configurations in Python-Based Software for ERT Data in Shallow Hazard Detection
Electrical Resistivity Tomography (ERT) is a widely used geophysical technique for imaging subsurface resistivity variations, providing critical insights for geological engineering and hazard assessment applications. While open-source inversion tools such as BERT and PyGIMLi offer accessible solutions for geoelectrical modeling, their comparative performance across different electrode configurations and noise conditions remains underexplored. This study evaluates the effectiveness of these software packages in reconstructing subsurface anomalies related to cavity detection and landslide assessment. Four commonly used electrode configurations—dipole–dipole, Schlumberger, Wenner-Alpha, and Wenner-Beta—were tested on two synthetic models designed to simulate real geological conditions: one representing cavity detection and the other simulating a landslide scenario. Inversions were conducted under both ideal conditions and with synthetic noise to assess their robustness against measurement uncertainties. Results indicate that while all configurations successfully identified major subsurface features, the dipole–dipole array provided the highest resolution for detecting small-scale anomalies. BERT demonstrated superior accuracy under ideal conditions, while PyGIMLi showed consistent performance across multiple configurations, particularly in resolving smaller features under noisy conditions. These findings emphasize the importance of selecting appropriate electrode configurations to enhance imaging accuracy and ensure reliable geo-electrical data interpretation. This study highlights the robustness of open-source geophysical software for subsurface investigations and provides practical insights into optimizing geoelectrical survey configurations for shallow hazard detection.