Markéta Bocková
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Markéta Bocková has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Jiří Homola
Institute of Photonics and Electronics of the Czech Academy of Sciences, Prague, Czech Republic
3 shared publications - Karel Chadt
Institute of Photonics and Electronics of the Czech Academy of Sciences, Prague, Czech Republic
2 shared publications Erika Gedeonová
Department of Optical Sensors, Institute of Photonics and Electronics of the CAS, Prague 8, Czech Republic
1 shared publication- Giusy Finocchiaro
Institute of Photonics and Electronics of the Czech Academy of Sciences
1 shared publication - Hana Šípová
Department of Physics
1 shared publication Jiří Homola
1 shared publication
Latest Publications
- 18 January 2026
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 453
Surface plasmon resonance imaging biosensor based on diffraction gratings with a linearly increasing period
- 18 January 2026
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 453
Surface plasmon resonance imaging biosensor based on diffraction gratings with a linearly increasing period
- 14 June 2016
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 408 (26) , 7265-7269
Surface plasmon resonance biosensor for detection of pregnancy associated plasma protein A2 in clinical samples
Pregnancy associated plasma protein A2 (PAPP-A2) is a metalloproteinase that plays multiple roles in fetal development and post-natal growth. Here we present a novel surface plasmon resonance (SPR) biosensor for the rapid and quantitative detection of PAPP-A2 in blood samples. This biosensor uses a single surface referencing approach and a sandwich assay with functionalized gold nanoparticles for signal enhancement. We demonstrate that this SPR biosensor enables the detection of PAPP-A2 in 30 % blood plasma at levels as low as 3.6 ng/mL. We also characterize the performance of the biosensor and evaluate its cross-reactivity to a PAPP-A analogue. Finally, we utilize this SPR biosensor for the detection of PAPP-A2 in blood serum from two groups of subjects: pregnant women and healthy non-pregnant women and men. Temporal sensor response corresponding to respective steps of the assay for detection of PAPP-A2 in buffer
- 14 June 2016
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 408 (26) , 7265-7269
Surface plasmon resonance biosensor for detection of pregnancy associated plasma protein A2 in clinical samples
Pregnancy associated plasma protein A2 (PAPP-A2) is a metalloproteinase that plays multiple roles in fetal development and post-natal growth. Here we present a novel surface plasmon resonance (SPR) biosensor for the rapid and quantitative detection of PAPP-A2 in blood samples. This biosensor uses a single surface referencing approach and a sandwich assay with functionalized gold nanoparticles for signal enhancement. We demonstrate that this SPR biosensor enables the detection of PAPP-A2 in 30 % blood plasma at levels as low as 3.6 ng/mL. We also characterize the performance of the biosensor and evaluate its cross-reactivity to a PAPP-A analogue. Finally, we utilize this SPR biosensor for the detection of PAPP-A2 in blood serum from two groups of subjects: pregnant women and healthy non-pregnant women and men. Temporal sensor response corresponding to respective steps of the assay for detection of PAPP-A2 in buffer
- Open Access
- 1 January 2011
- Published by Elsevier in Procedia Engineering
- Vol. 25, 148-151
Portable Surface Plasmon Resonance Biosensor for Detection of Nucleic Acids
- 1 January 2011
- Published by Elsevier in Procedia Engineering
- Vol. 25, 148-151
Open AccessPortable Surface Plasmon Resonance Biosensor for Detection of Nucleic Acids