Wang Deng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Wang Deng has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Yong Huang
Department of Orthopedics, National Center for Orthopaedics, Beijing Jishuitan Hospital Capital Medical University Beijing China
2 shared publications - Daoxin Wang
Department of Respiratory and Critical Care Medicine, the Second Affiliated Hospital of Chongqing Medical University, Chongqing 400010, China
1 shared publication - Dejin Yang
Department of Orthopaedic Surgery, Beijing Jishuitan Hospital, Capital Medical University, Beijing, China
1 shared publication - Guoqing Li
Department of Orthopedics, National Center for Orthopaedics, Beijing Jishuitan Hospital Capital Medical University Beijing China
1 shared publication - Hao Tang
Peking University Fourth School of Clinical Medicine, Beijing, China
1 shared publication - Hongyi Shao
Department of Orthopaedics, Beijing Jishuitan Hospital Affiliated to Capital Medical University, Beijing, China
1 shared publication
Latest Publications
- Open Access
- 12 May 2026
- Published by Wiley in Orthopaedic Surgery
- Vol. 18 (6) , 1155-1172
What Are the Optimal Sagittal Alignments in Primary Total Knee Arthroplasty: A Systematic Review and Meta‐Analysis
Objective: Total knee arthroplasty (TKA) is a well‐established intervention for end‐stage osteoarthritis (OA), offering substantial pain relief and functional improvement. However, a considerable proportion of patients remain dissatisfied postoperatively due to multifactorial causes. While numerous studies have investigated implant alignment, the sagittal plane alignment has received comparatively less attention, and its clinical relevance remains controversial. This systematic review aims to identify the optimal sagittal alignment (SA) parameters in TKA and to evaluate their impact on clinical outcomes. Methods: A comprehensive literature search was conducted across four databases (PubMed, the Cochrane Library, Embase, and Web of Science) from their inception to April 1, 2025. Studies focusing on SA after primary TKA were considered. Articles meeting the inclusion and exclusion criteria were subjected to meta‐analysis. The SA parameters assessed included tibial slope, posterior condylar offset, tibial and femoral component angles, femoral bowing angle, and tibiofemoral alignment. Results: The search yielded 1414 articles, after removing duplicates, of which 30 studies met the final inclusion criteria. The review confirmed that SA plays a critical role in postoperative outcomes. Malalignment in the sagittal plane was associated with complications such as instability, hyperextension, and impaired functional recovery. In particular, deviations in tibial slope and femoral bowing angle significantly influenced overall limb alignment and joint mechanics. Although achieving proper SA appears to reduce complications and improve functional outcomes, no universally accepted target values have yet been established. Conclusion: Based on current evidence, achieving optimal SA during the perioperative period is essential for improving prosthesis longevity and patient satisfaction following primary TKA. Surgeons should pay close attention to SA parameters, and the use of emerging technologies is encouraged to enhance precision in component positioning. Trial Registration: PROSPERO Registration: CRD42023471336
- 12 May 2026
- Published by Wiley in Orthopaedic Surgery
- Vol. 18 (6) , 1155-1172
Open AccessWhat Are the Optimal Sagittal Alignments in Primary Total Knee Arthroplasty: A Systematic Review and Meta‐Analysis
Objective: Total knee arthroplasty (TKA) is a well‐established intervention for end‐stage osteoarthritis (OA), offering substantial pain relief and functional improvement. However, a considerable proportion of patients remain dissatisfied postoperatively due to multifactorial causes. While numerous studies have investigated implant alignment, the sagittal plane alignment has received comparatively less attention, and its clinical relevance remains controversial. This systematic review aims to identify the optimal sagittal alignment (SA) parameters in TKA and to evaluate their impact on clinical outcomes. Methods: A comprehensive literature search was conducted across four databases (PubMed, the Cochrane Library, Embase, and Web of Science) from their inception to April 1, 2025. Studies focusing on SA after primary TKA were considered. Articles meeting the inclusion and exclusion criteria were subjected to meta‐analysis. The SA parameters assessed included tibial slope, posterior condylar offset, tibial and femoral component angles, femoral bowing angle, and tibiofemoral alignment. Results: The search yielded 1414 articles, after removing duplicates, of which 30 studies met the final inclusion criteria. The review confirmed that SA plays a critical role in postoperative outcomes. Malalignment in the sagittal plane was associated with complications such as instability, hyperextension, and impaired functional recovery. In particular, deviations in tibial slope and femoral bowing angle significantly influenced overall limb alignment and joint mechanics. Although achieving proper SA appears to reduce complications and improve functional outcomes, no universally accepted target values have yet been established. Conclusion: Based on current evidence, achieving optimal SA during the perioperative period is essential for improving prosthesis longevity and patient satisfaction following primary TKA. Surgeons should pay close attention to SA parameters, and the use of emerging technologies is encouraged to enhance precision in component positioning. Trial Registration: PROSPERO Registration: CRD42023471336
- 1 April 2025
- Published by British Editorial Society of Bone & Joint Surgery in The Bone & Joint Journal
- Vol. 107-B (4) , 404-412
Robotic arm-assisted acetabular reconstruction in revision total hip arthroplasty
Aims: This study aimed to report the surgical techniques and early clinical results of robotic arm-assisted acetabular reconstruction in revision total hip arthroplasty (THA).Methods: Between October 2019 and May 2021, we used the Mako robotic system to perform 62 revision THAs at our hospital. This study included 54 patients who underwent robotic arm-assisted revision THA for acetabular reconstruction. Surgical techniques using the robotic system to reconstruct the acetabulum, including preoperative planning, intraoperative registration, and the accuracy of different registration methods, are reported. The accuracy between the target acetabular component orientation and final orientation was evaluated. The latest follow-up Harris Hip Score (HHS) and radiographs were analyzed.Results: Among the 54 hips included, four types of intraoperative registration methods with different surfaces were developed and registered 65 times. The overall success rate of the registration process was 98.5%. The mean accuracy of successful registration was 0.38 mm (0.2 to 0.5). The median difference between the target and final acetabular component orientations assessed by Mako was 1.0° (-2.0° to 0.0°) for inclination and 0.0° (-1.0° to 1.0°) for anteversion. Four hips were classified as outliers for acetabular component orientation. The reconstructed centres of rotation (CORs) were slightly lower than the anatomical CORs by a mean 4.72 mm (SD 4.71), and shifted laterally by 3.92 mm (SD 4.62) on postoperative radiographs. The median HHS improved significantly from 46.0 (IQR 33.0 to 58.3) preoperatively to 89.0 (IQR 78.3 to 93.0) postoperatively (p < 0.001). The overall satisfaction rate was 86.0% (n = 50). There were no radiological failures at the latest follow-up.Conclusion: Robotic arm-assisted revision THA provides valuable information for the analysis of bone defects to guide reconstructive strategies. Robotic arm-assisted reaming and acetabular component or augment positioning facilitates accurate component position and orientation. The radiological and preliminary clinical results of this cohort were satisfactory.Cite this article: Bone Joint J 2025;107-B(4):404–412.
- 1 April 2025
- Published by British Editorial Society of Bone & Joint Surgery in The Bone & Joint Journal
- Vol. 107-B (4) , 404-412
Robotic arm-assisted acetabular reconstruction in revision total hip arthroplasty
Aims: This study aimed to report the surgical techniques and early clinical results of robotic arm-assisted acetabular reconstruction in revision total hip arthroplasty (THA).Methods: Between October 2019 and May 2021, we used the Mako robotic system to perform 62 revision THAs at our hospital. This study included 54 patients who underwent robotic arm-assisted revision THA for acetabular reconstruction. Surgical techniques using the robotic system to reconstruct the acetabulum, including preoperative planning, intraoperative registration, and the accuracy of different registration methods, are reported. The accuracy between the target acetabular component orientation and final orientation was evaluated. The latest follow-up Harris Hip Score (HHS) and radiographs were analyzed.Results: Among the 54 hips included, four types of intraoperative registration methods with different surfaces were developed and registered 65 times. The overall success rate of the registration process was 98.5%. The mean accuracy of successful registration was 0.38 mm (0.2 to 0.5). The median difference between the target and final acetabular component orientations assessed by Mako was 1.0° (-2.0° to 0.0°) for inclination and 0.0° (-1.0° to 1.0°) for anteversion. Four hips were classified as outliers for acetabular component orientation. The reconstructed centres of rotation (CORs) were slightly lower than the anatomical CORs by a mean 4.72 mm (SD 4.71), and shifted laterally by 3.92 mm (SD 4.62) on postoperative radiographs. The median HHS improved significantly from 46.0 (IQR 33.0 to 58.3) preoperatively to 89.0 (IQR 78.3 to 93.0) postoperatively (p < 0.001). The overall satisfaction rate was 86.0% (n = 50). There were no radiological failures at the latest follow-up.Conclusion: Robotic arm-assisted revision THA provides valuable information for the analysis of bone defects to guide reconstructive strategies. Robotic arm-assisted reaming and acetabular component or augment positioning facilitates accurate component position and orientation. The radiological and preliminary clinical results of this cohort were satisfactory.Cite this article: Bone Joint J 2025;107-B(4):404–412.
- Open Access
- 1 February 2023
- Published by AME Publishing Company in Translational Cancer Research
- Vol. 12 (2) , 427-433
Successful treatment with osimertinib for nonmucinous bronchioloalveolar carcinoma with massive bronchorrhea and respiratory failure: a case report and literature review
Case Report Successful treatment with osimertinib for nonmucinous bronchioloalveolar carcinoma with massive bronchorrhea and respiratory failure: a case report and literature review Jin Tong, Dao-Xin Wang, Zhi-Yu Zhou, Wang Deng
- 1 February 2023
- Published by AME Publishing Company in Translational Cancer Research
- Vol. 12 (2) , 427-433
Open AccessSuccessful treatment with osimertinib for nonmucinous bronchioloalveolar carcinoma with massive bronchorrhea and respiratory failure: a case report and literature review
Case Report Successful treatment with osimertinib for nonmucinous bronchioloalveolar carcinoma with massive bronchorrhea and respiratory failure: a case report and literature review Jin Tong, Dao-Xin Wang, Zhi-Yu Zhou, Wang Deng