Tom Andre Pedersen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Tom Andre Pedersen has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
Birgitte Seip
Vestfold Hospital Trust, Norway
2 shared publicationsEdoardo Botteri
Cancer Registry of Norway, Norwegian Institute of Public Health, Norway
2 shared publicationsGeorg Gjorgji Dimcevski
Kanalspesialistene AS, Norway
2 shared publicationsRoald Flesland Havre
Haukeland University Hospital, Norway
2 shared publicationsTrond Engjom
Haukeland University Hospital, Norway
2 shared publications- Yuichi Mori
Department of Transplantation Medicine, Gastroenterology Section, Oslo University Hospital, Oslo, Norway
1 shared publication
Latest Publications
- Open Access
- 3 June 2026
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 58 (09) , 1003-1014
Learning and deskilling effects of artificial intelligence in colonoscopy among endoscopists with different levels of experience: a pragmatic, prospective trial
The effect of computer-aided detection (CADe) on performance of endoscopists with different experience levels is not well understood. This study assessed whether CADe use promotes learning or deskilling. We performed a prospective, multicenter, registry-based, pragmatic clinical trial. The primary end point was change in the proportion of colonoscopies with detection of at least one polyp ≥5 mm (PDR-5). Each endoscopist performed colonoscopies in three successive phases: 1) before CADe exposure, 2) during CADe use, and 3) after CADe removal. To assess the impact of CADe on PDR-5, we compared phase 1 with phases 2 and 3, adjusting for patient and endoscopist characteristics and endoscopy performance measures. Generalized linear mixed models were used and presented according to endoscopist experience. 13 endoscopists (7 inexperienced, 6 experienced) performed 5013 colonoscopies; median patient age was 59 years (interquartile range 44–71) and 2703 (53.9%) were women. Patient sex and age were similar across the two experience groups, whereas indications differed (e.g. more inflammatory bowel disease in the inexperienced group). CADe temporarily increased PDR-5 among inexperienced endoscopists from phase 1 to 2 (31.9% [216/678] to 39.5% [257/651]; odds ratio [OR] 1.43, 95%CI 1.11–1.84). There was no significant change between phases 1 and 3 (31.9% [216/678] to 36.3% [173/476]; OR 1.03, 95%CI 0.79–1.34). There was no significant CADe effect on PDR-5 among experienced endoscopists between phases. PDR-5 of inexperienced endoscopists increased when CADe was used. In non-CADe-assisted colonoscopy, no upskilling or deskilling was observed following a period of CADe exposure.
- 3 June 2026
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 58 (09) , 1003-1014
Open AccessLearning and deskilling effects of artificial intelligence in colonoscopy among endoscopists with different levels of experience: a pragmatic, prospective trial
The effect of computer-aided detection (CADe) on performance of endoscopists with different experience levels is not well understood. This study assessed whether CADe use promotes learning or deskilling. We performed a prospective, multicenter, registry-based, pragmatic clinical trial. The primary end point was change in the proportion of colonoscopies with detection of at least one polyp ≥5 mm (PDR-5). Each endoscopist performed colonoscopies in three successive phases: 1) before CADe exposure, 2) during CADe use, and 3) after CADe removal. To assess the impact of CADe on PDR-5, we compared phase 1 with phases 2 and 3, adjusting for patient and endoscopist characteristics and endoscopy performance measures. Generalized linear mixed models were used and presented according to endoscopist experience. 13 endoscopists (7 inexperienced, 6 experienced) performed 5013 colonoscopies; median patient age was 59 years (interquartile range 44–71) and 2703 (53.9%) were women. Patient sex and age were similar across the two experience groups, whereas indications differed (e.g. more inflammatory bowel disease in the inexperienced group). CADe temporarily increased PDR-5 among inexperienced endoscopists from phase 1 to 2 (31.9% [216/678] to 39.5% [257/651]; odds ratio [OR] 1.43, 95%CI 1.11–1.84). There was no significant change between phases 1 and 3 (31.9% [216/678] to 36.3% [173/476]; OR 1.03, 95%CI 0.79–1.34). There was no significant CADe effect on PDR-5 among experienced endoscopists between phases. PDR-5 of inexperienced endoscopists increased when CADe was used. In non-CADe-assisted colonoscopy, no upskilling or deskilling was observed following a period of CADe exposure.
- Open Access
- 7 January 2025
- Published by Georg Thieme Verlag KG in Endoscopy International Open
- Vol. 13 (CP) , a25469515
Differences in colonoscopy performance among four endoscopy centers in Western Norway: Influence of case-mix
Unmodifiable patient factors such as age, sex, and indication (case-mix) may influence colonoscopy performance. In this study, we explored how case-mix affected polyp detection, cecal intubation, and pain on a center level.A cross-sectional study was performed on data from four centers in Western Norway registered in the national endoscopy quality registry, Gastronet, in 2020 and 2021. We extracted demographics, indication, and the performance measures cecal intubation rate (CIR), proportion of at least one polyp ≥ 5 mm in size per colonoscopy (PDR-5), and pain. We also analyzed the explanatory variables bowel preparation, withdrawal time, and sedation/analgesia.First colonoscopies in 14,765 patients were included. Median age was 60 years (interquartile range 46–71) and 54% were women. Case-mix differed between centers and significantly influenced performance measures. Increased PDR-5 was associated with higher age and male sex (odds ratio [OR] 1.27, 95% confidence interval [CI] 1.18–1.37). The indication surveillance had the highest PDR-5 (44.9%, 95% CI 42.6–47.1) and inflammatory bowel disease the lowest (14.6%, 95% CI 12.3–16.8). CIR decreased with increasing age. Men had less pain (OR 0.33, 95% CI 0.27–0.39). Among indications, surveillance and IBD had higher CIRs and less pain. Performance measures differed among centers, even after adjustment for case-mix and other known explanatory variables such as sedation/analgesia and bowel preparation.Case-mix influenced performance measures. Although we showed center differences in performance, other factors, such as individual endoscopist skills, probably influence performance measures. Our study demonstrates the importance of considering case-mix when assessing colonoscopy performance.
- 7 January 2025
- Published by Georg Thieme Verlag KG in Endoscopy International Open
- Vol. 13 (CP) , a25469515
Open AccessDifferences in colonoscopy performance among four endoscopy centers in Western Norway: Influence of case-mix
Unmodifiable patient factors such as age, sex, and indication (case-mix) may influence colonoscopy performance. In this study, we explored how case-mix affected polyp detection, cecal intubation, and pain on a center level.A cross-sectional study was performed on data from four centers in Western Norway registered in the national endoscopy quality registry, Gastronet, in 2020 and 2021. We extracted demographics, indication, and the performance measures cecal intubation rate (CIR), proportion of at least one polyp ≥ 5 mm in size per colonoscopy (PDR-5), and pain. We also analyzed the explanatory variables bowel preparation, withdrawal time, and sedation/analgesia.First colonoscopies in 14,765 patients were included. Median age was 60 years (interquartile range 46–71) and 54% were women. Case-mix differed between centers and significantly influenced performance measures. Increased PDR-5 was associated with higher age and male sex (odds ratio [OR] 1.27, 95% confidence interval [CI] 1.18–1.37). The indication surveillance had the highest PDR-5 (44.9%, 95% CI 42.6–47.1) and inflammatory bowel disease the lowest (14.6%, 95% CI 12.3–16.8). CIR decreased with increasing age. Men had less pain (OR 0.33, 95% CI 0.27–0.39). Among indications, surveillance and IBD had higher CIRs and less pain. Performance measures differed among centers, even after adjustment for case-mix and other known explanatory variables such as sedation/analgesia and bowel preparation.Case-mix influenced performance measures. Although we showed center differences in performance, other factors, such as individual endoscopist skills, probably influence performance measures. Our study demonstrates the importance of considering case-mix when assessing colonoscopy performance.