LXL. P. Xiang
L. P. Xiang
*This is an algorithmically generated author record based on publicly available information.
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
L. P. Xiang has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Cong Guo
Experimental Physics Division, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing, China
3 shared publications C. B. Z. Luo
School of Nuclear Science and Technology, University of South China, Hengyang, CHINA
2 shared publicationsC. G. Yang
Experimental Physics Division, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing, China
2 shared publicationsJ. C. Liu
Experimental Physics Division, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing, China
2 shared publicationsQ. Tang
School of Nuclear Science and Technology University of South China 421001 Hengyang China
2 shared publicationsY. P. Zhang
Experimental Physics Division, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing, China
2 shared publications
Latest Publications
- 17 March 2026
- Published by Springer Nature in Radiation Detection Technology and Methods
- Vol. 10 (5) , 1086-1095
Precise measurement and control of radon progeny on detector surfaces
- 17 March 2026
- Published by Springer Nature in Radiation Detection Technology and Methods
- Vol. 10 (5) , 1086-1095
Precise measurement and control of radon progeny on detector surfaces
- Open Access
Measurement of radon concentration in the output water of the 100~t/h ultrapure water system at the Jiangmen Underground Neutrino Observatory
The Jiangmen Underground Neutrino Observatory (JUNO), a 20 kton multi-purpose low background liquid scintillator detector, was proposed primarily to determine the neutrino mass ordering. To mitigate radioactivity from surrounding rock and enable cosmic muon tagging, its central detector is immersed in a Water Cherenkov Detector (WCD) containing 40~ktons of ultrapure water instrumented with 2400 20-inch micro-channel plate photomultiplier tubes. Stringent radiopurity requirements mandate a radon concentration below 10 ~mBq/m$^3$ in the WCD. To achieve this, we developed a two-stage (ground and underground) ultrapure water system with 100~t/h production capacity, integrating a five-stage degassing membrane for radon removal. A novel microbubble technique was implemented to optimize the degassing membranes' radon removal efficiency. The synergistic combination of the microbubble technology and the multistage degassing membranes achieved a radon removal efficiency exceeding 99.9\%, reducing the system's output to 0.61 $\pm$ 0.50~mBq/m$^3$ in recirculation mode, surpassing design specifications and establishing world-leading performance standards. This paper details the ultrapure system architecture, quantifies the radon contributions of each device, and presents a comprehensive study on microbubble-augmented membrane degassing for low radon ultra-pure water production in a 100~t/h water system.Open AccessMeasurement of radon concentration in the output water of the 100~t/h ultrapure water system at the Jiangmen Underground Neutrino Observatory
The Jiangmen Underground Neutrino Observatory (JUNO), a 20 kton multi-purpose low background liquid scintillator detector, was proposed primarily to determine the neutrino mass ordering. To mitigate radioactivity from surrounding rock and enable cosmic muon tagging, its central detector is immersed in a Water Cherenkov Detector (WCD) containing 40~ktons of ultrapure water instrumented with 2400 20-inch micro-channel plate photomultiplier tubes. Stringent radiopurity requirements mandate a radon concentration below 10 ~mBq/m$^3$ in the WCD. To achieve this, we developed a two-stage (ground and underground) ultrapure water system with 100~t/h production capacity, integrating a five-stage degassing membrane for radon removal. A novel microbubble technique was implemented to optimize the degassing membranes' radon removal efficiency. The synergistic combination of the microbubble technology and the multistage degassing membranes achieved a radon removal efficiency exceeding 99.9\%, reducing the system's output to 0.61 $\pm$ 0.50~mBq/m$^3$ in recirculation mode, surpassing design specifications and establishing world-leading performance standards. This paper details the ultrapure system architecture, quantifies the radon contributions of each device, and presents a comprehensive study on microbubble-augmented membrane degassing for low radon ultra-pure water production in a 100~t/h water system. - 4 April 2025
- Published by Springer Nature in Radiation Detection Technology and Methods
- Vol. 9 (4) , 592-599
Developing a Bq/L level $^{131}\text {I}$ concentration in solution measurement system using NaI(Tl) crystal and SiPM- 4 April 2025
- Published by Springer Nature in Radiation Detection Technology and Methods
- Vol. 9 (4) , 592-599
Developing a Bq/L level $^{131}\text {I}$ concentration in solution measurement system using NaI(Tl) crystal and SiPM