Akihiro Karashima
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Akihiro Karashima has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Ikuko N. Motoike
Tohoku Medical Megabank Organization, Tohoku University, Sendai, Japan
1 shared publication - Kengo Kinoshita
Tohoku Medical Megabank Organization, Tohoku University, Sendai, Japan
1 shared publication - Kohsuke Tajima
Faculty of Engineering, Tohoku Institute of Technology, 35-1 Yagiyamakasumicho, Taihaku-ku, Sendai 982-8577, Miyagi, Japan
1 shared publication - Mahiro Osada
Faculty of Engineering, Tohoku Institute of Technology, 35-1 Yagiyamakasumicho, Taihaku-ku, Sendai 982-8577, Miyagi, Japan
1 shared publication - Mitsuyuki Nakao
Graduate School of Information Sciences, Tohoku University, Sendai, Japan
1 shared publication Norihiro Katayama
Graduate School of Information Sciences, Tohoku University, Sendai, Japan
1 shared publication
Latest Publications
- Open Access
- 8 April 2025
- Published by MDPI AG in Chemosensors
- Vol. 13 (4) , 136
Small Acetone Sensor with a Porous Colorimetric Chip for Breath Acetone Detection Using the Flow–Stop Method
Acetone is a well-known biogas involved in lipid metabolism and is considered a potential biomarker for diabetes. However, the conventional detection methods for acetone face the limitations of large size, complex usage, and cross-sensitivity. In this study, we developed a portable device comprising a porous colorimetric acetone analytical chip composed of 2-nitrophenyl hydrazine and porous glass. The analytical chip was highly sensitive and selective for acetone because it was based on the chemical reaction between acetone and hydrazine in a nanoporous material, which provides a large surface area. The device consisted of a 450 nm laser light source and a photodiode detector with a volume of less than 40 mL. Acetone gas was measured in the atmosphere for 10 min using the developed flow–stop method. The measurable acetone concentration ranged from 0 to 6.0 ppm with a detection limit of 0.22 ppm. We successfully conducted a feasibility study using human exhaled breath and analyzed the relationship between exercise and the acetone concentration in the breath. An upward trend in exhaled acetone levels was seen post-exercise for each individual.
- 8 April 2025
- Published by MDPI AG in Chemosensors
- Vol. 13 (4) , 136
Open AccessSmall Acetone Sensor with a Porous Colorimetric Chip for Breath Acetone Detection Using the Flow–Stop Method
Acetone is a well-known biogas involved in lipid metabolism and is considered a potential biomarker for diabetes. However, the conventional detection methods for acetone face the limitations of large size, complex usage, and cross-sensitivity. In this study, we developed a portable device comprising a porous colorimetric acetone analytical chip composed of 2-nitrophenyl hydrazine and porous glass. The analytical chip was highly sensitive and selective for acetone because it was based on the chemical reaction between acetone and hydrazine in a nanoporous material, which provides a large surface area. The device consisted of a 450 nm laser light source and a photodiode detector with a volume of less than 40 mL. Acetone gas was measured in the atmosphere for 10 min using the developed flow–stop method. The measurable acetone concentration ranged from 0 to 6.0 ppm with a detection limit of 0.22 ppm. We successfully conducted a feasibility study using human exhaled breath and analyzed the relationship between exercise and the acetone concentration in the breath. An upward trend in exhaled acetone levels was seen post-exercise for each individual.
- 5 May 2020
- Published by Springer Nature in Sleep and Biological Rhythms
- Vol. 18 (4) , 297-304
Consistency index of daily activity pattern and its correlations with subjective ratings of QOL
- 5 May 2020
- Published by Springer Nature in Sleep and Biological Rhythms
- Vol. 18 (4) , 297-304
Consistency index of daily activity pattern and its correlations with subjective ratings of QOL