Bogdan Ligaj
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Bogdan Ligaj has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Karolina Karolewska
Faculty of Mechanical Engineering, al. PBS Bydgoszcz University of Science and Technology, Kaliskiego 7, 85-796 Bydgoszcz, Poland
2 shared publications Andrzej Grączewski
UTP University of Science and Technology in Bydgoszcz, Faculty of Mechanical Engineering, al. Prof. S. Kaliskiego 7, 85-796 Bydgoszcz, Poland
1 shared publication- Janusz Musiał
Faculty of Mechatronics, Kazimierz Wielki University, Mikołaja Kopernika 1, 85-074 Bydgoszcz, Poland
1 shared publication - Katarzyna Zasińska
Gdańsk University of Technology, Faculty of Mechanical Engineering and Ship Technology, Division of Machine Design and Medical Engineering
1 shared publication - Mateusz Wirwicki
Faculty of Mechatronics, ul. UKW Kazimierz Wielki University, Kopernika 1, 85-074 Bydgoszcz, Poland
1 shared publication Oleksandr Dykha
Khmelnytskyi National University, Faculty of Engineering, Transport and Architecture, Ukraine
1 shared publication
Latest Publications
- 31 March 2025
- Published by Index Copernicus in Tribologia
- Vol. 311 (1) , 29-36
TRIBOLOGICAL PROPERTIES AND SURFACE ROUGHNESS OF PRINTED Ti-6Al-4V/PE-UHMW FRICTION PAIR ELEMENTS
The article presents tribological research on the cooperation of a kinematic pair composed of metallic and polymer biomaterials. In the sample tests, a material widely used in orthopaedics and dentistry was used (the medical titanium alloy Ti-6Al-4V obtained both by traditional manufacturing methods, i.e. casting, and the additive manufacturing method SLM/DLMS (3D printing)) and a counter sample (high-density polyethylene PE-UHMW). The friction pair selected in this way was subjected to tribological tests on a PT-3 tribometer under specific operating conditions. After the tribological tests, the change in tribological parameters, i.e. the coefficient of friction or abrasive wear on the surfaces of the tested biomaterials, was evaluated. The obtained results also enabled the assessment of the changes occurring in the geometric structure of the surface of the Ti-6Al-4V/ PE-UHMW friction pair for titanium samples obtained via drawn rod and 3D printing.
- 31 March 2025
- Published by Index Copernicus in Tribologia
- Vol. 311 (1) , 29-36
TRIBOLOGICAL PROPERTIES AND SURFACE ROUGHNESS OF PRINTED Ti-6Al-4V/PE-UHMW FRICTION PAIR ELEMENTS
The article presents tribological research on the cooperation of a kinematic pair composed of metallic and polymer biomaterials. In the sample tests, a material widely used in orthopaedics and dentistry was used (the medical titanium alloy Ti-6Al-4V obtained both by traditional manufacturing methods, i.e. casting, and the additive manufacturing method SLM/DLMS (3D printing)) and a counter sample (high-density polyethylene PE-UHMW). The friction pair selected in this way was subjected to tribological tests on a PT-3 tribometer under specific operating conditions. After the tribological tests, the change in tribological parameters, i.e. the coefficient of friction or abrasive wear on the surfaces of the tested biomaterials, was evaluated. The obtained results also enabled the assessment of the changes occurring in the geometric structure of the surface of the Ti-6Al-4V/ PE-UHMW friction pair for titanium samples obtained via drawn rod and 3D printing.
- Open Access
- 6 January 2021
- Published by EDP Sciences in MATEC Web of Conferences
- Vol. 332, 01015
Analysis of selected geometrical features of a structural element on the example of a dental implant
The aim of the article was to carry out FEM strength tests for four proposed by the authors geometry of the intraoral implant. Change of their geometrical features to find the most optimal distribution of reduced stresses. The article presents various geometries of the new dental implant. Strength tests were performed using the finite element method (FEM). The results of the tests were analyzed and their assessment was made for which of the solutions of the new geometry the stress distribution is the most optimal. Detailed results of the analyzes for a given model are shown and new solutions in the construction of the implant are proposed.
- 6 January 2021
- Published by EDP Sciences in MATEC Web of Conferences
- Vol. 332, 01015
Open AccessAnalysis of selected geometrical features of a structural element on the example of a dental implant
The aim of the article was to carry out FEM strength tests for four proposed by the authors geometry of the intraoral implant. Change of their geometrical features to find the most optimal distribution of reduced stresses. The article presents various geometries of the new dental implant. Strength tests were performed using the finite element method (FEM). The results of the tests were analyzed and their assessment was made for which of the solutions of the new geometry the stress distribution is the most optimal. Detailed results of the analyzes for a given model are shown and new solutions in the construction of the implant are proposed.
- Open Access
- 21 August 2019
- Published by EDP Sciences in MATEC Web of Conferences
- Vol. 290, 08010
Mechanical properties comparison of Ti6Al4V produced by different technologies under static load conditions
The most commonly used technology among the additive manufacturing is Direct Metal Laser Sintering (DMLS). This process is based on selective laser sintering (SLS). The method gained its popularity due to the possibility of producing metal parts of any geometry, which would be difficult or impossible to obtain by the use of conventional manufacturing techniques. Materials used in the elements manufacturing process are: titanium alloys (e.g. Ti6Al4V), aluminium alloy AlSi10Mg, etc. Elements printed from Ti6Al4V titanium alloy find their application in many industries. Details produced by additive technology are often used in medicine as skeletal, and dental implants. Another example of the DMLS elements use is the aerospace industry. In this area, the additive manufacturing technology produces, i.a. parts of turbines. In addition to the aerospace and medical industries, DMLS technology is also used in motorsport for exhaust pipes or the gearbox parts. The research objects are samples for static tests. These samples were made of Ti6Al4V alloy by the DMLS method and the rolling method from a drawn rod. The aim of the paper is the mechanical properties comparative analysis of the Ti6Al4V alloy produced by the DMLS method under static loading conditions and microstructure analysis of this material.
- 21 August 2019
- Published by EDP Sciences in MATEC Web of Conferences
- Vol. 290, 08010
Open AccessMechanical properties comparison of Ti6Al4V produced by different technologies under static load conditions
The most commonly used technology among the additive manufacturing is Direct Metal Laser Sintering (DMLS). This process is based on selective laser sintering (SLS). The method gained its popularity due to the possibility of producing metal parts of any geometry, which would be difficult or impossible to obtain by the use of conventional manufacturing techniques. Materials used in the elements manufacturing process are: titanium alloys (e.g. Ti6Al4V), aluminium alloy AlSi10Mg, etc. Elements printed from Ti6Al4V titanium alloy find their application in many industries. Details produced by additive technology are often used in medicine as skeletal, and dental implants. Another example of the DMLS elements use is the aerospace industry. In this area, the additive manufacturing technology produces, i.a. parts of turbines. In addition to the aerospace and medical industries, DMLS technology is also used in motorsport for exhaust pipes or the gearbox parts. The research objects are samples for static tests. These samples were made of Ti6Al4V alloy by the DMLS method and the rolling method from a drawn rod. The aim of the paper is the mechanical properties comparative analysis of the Ti6Al4V alloy produced by the DMLS method under static loading conditions and microstructure analysis of this material.
- Open Access
- 21 February 2019
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2077 (1) , 020023
Influence of the welding method on the strength of structural elements of machines made of aluminum alloy EN AW-5754
The paper presents the experimental tests results of aluminum alloy EN AW-5754 sample strength. The test specimens were made of metal sheet with a thickness 3.9 mm. The tinware joining process was carried out based on the method 131 for two different welding parameters. The first set of welding parameters (option A): voltage U = 25 V, current intensity I = 160 A, linear welding speed v = 400 mm/min, coefficient k = 0.8, linear welding energy Q = 1280 kJ/mm. The second set of welding parameters (option B): voltage U = 13.5 V, current I = 140 A, linear welding speed v = 62 mm/min, coefficient k = 0.6, linear welding energy Q = 70.3 kJ/mm. The obtained experimental results shows that the welding parameters choice by the method 131 did not affect the strength properties of the joints (including the yield point value Sy0.2). However, it influenced the elongation of the sample A.
- 21 February 2019
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2077 (1) , 020023
Open AccessInfluence of the welding method on the strength of structural elements of machines made of aluminum alloy EN AW-5754
The paper presents the experimental tests results of aluminum alloy EN AW-5754 sample strength. The test specimens were made of metal sheet with a thickness 3.9 mm. The tinware joining process was carried out based on the method 131 for two different welding parameters. The first set of welding parameters (option A): voltage U = 25 V, current intensity I = 160 A, linear welding speed v = 400 mm/min, coefficient k = 0.8, linear welding energy Q = 1280 kJ/mm. The second set of welding parameters (option B): voltage U = 13.5 V, current I = 140 A, linear welding speed v = 62 mm/min, coefficient k = 0.6, linear welding energy Q = 70.3 kJ/mm. The obtained experimental results shows that the welding parameters choice by the method 131 did not affect the strength properties of the joints (including the yield point value Sy0.2). However, it influenced the elongation of the sample A.