Ernest Bwogi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ernest Bwogi has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Davide Piaggio
University of Warwick
2 shared publications - Leandro Pecchia
Università Campus Bio-Medico di Roma
2 shared publications - Ciara Higley
School of Engineering, University of Warwick, Coventry, UK
1 shared publication - Jacob A. Oyarzabal
Department of Chemistry, University of Warwick, Coventry CV4 7AL, UK
1 shared publication - Jiras Casimir Kpego Ligan
Department of Engineering, Università Campus Bio-Medico di Roma, Rome, ITALY
1 shared publication - Karina Ovejero‐Paredes
Department of Engineering, Università Campus Bio-Medico di Roma, Rome, ITALY
1 shared publication
Latest Publications
- Open Access
- 1 April 2026
- Published by BMJ in BMJ Public Health
- Vol. 4 (2) , e003145
How technologies are driving digital innovation in mosquito surveillance systems: a global scoping review over the past decade
Objectives: This review investigates the recent advancements aimed at optimising vector control through enhanced mosquito monitoring. Recent advancements in artificial intelligence (AI), internet of things (IoT) and remote sensing have been explored to enhance surveillance but a comprehensive review of their progress was needed. Design: Scoping review following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses 2020 guidelines. Data sources: Systematic searches were performed in PubMed and Scopus focusing on studies published between January 2014 and June 2024 Eligibility criteria: Original studies focusing on mosquitoes and addressing the design, development, testing, implementation, as well as the evaluation of smart traps or modification, upgrade or digitisation of traditional mosquito traps or surveillance systems were included. Data extraction and synthesis: Key information relevant to this review was extracted into an Excel spreadsheet and narratively synthesised. We assessed the scientific quality of the studies included in this review based on their designs and especially on their resulting outcomes. Results: This work highlights the increasing integration of AI in mosquito identification and classification, complemented by environmental sensors for real-time monitoring of parameters such as temperature, humidity and landscape features. Additionally, the convergence of AI with IoT systems, robotic traps and remote sensing technologies, including drones and geographic information systems , enables the collection of granular data on mosquito populations and their habitats, facilitating proactive control measures. Overall, these smart surveillance technologies offer a transformative advancement in vector control, enabling more precise and efficient interventions. However, their widespread adoption will require thorough evaluation of cost-effectiveness, scalability and adaptability across diverse settings. Conclusions: This review maps the evolution of smart mosquito surveillance over the past decade, highlighting AI-driven species identification, IoT-enabled real-time monitoring and the integration of remote sensing technologies. It provides a structured analysis of how these innovations improve mosquito detection and data accuracy. These insights can guide further research, inform practical implementations and shape policy decisions in public health and mosquito surveillance.
- 1 April 2026
- Published by BMJ in BMJ Public Health
- Vol. 4 (2) , e003145
Open AccessHow technologies are driving digital innovation in mosquito surveillance systems: a global scoping review over the past decade
Objectives: This review investigates the recent advancements aimed at optimising vector control through enhanced mosquito monitoring. Recent advancements in artificial intelligence (AI), internet of things (IoT) and remote sensing have been explored to enhance surveillance but a comprehensive review of their progress was needed. Design: Scoping review following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses 2020 guidelines. Data sources: Systematic searches were performed in PubMed and Scopus focusing on studies published between January 2014 and June 2024 Eligibility criteria: Original studies focusing on mosquitoes and addressing the design, development, testing, implementation, as well as the evaluation of smart traps or modification, upgrade or digitisation of traditional mosquito traps or surveillance systems were included. Data extraction and synthesis: Key information relevant to this review was extracted into an Excel spreadsheet and narratively synthesised. We assessed the scientific quality of the studies included in this review based on their designs and especially on their resulting outcomes. Results: This work highlights the increasing integration of AI in mosquito identification and classification, complemented by environmental sensors for real-time monitoring of parameters such as temperature, humidity and landscape features. Additionally, the convergence of AI with IoT systems, robotic traps and remote sensing technologies, including drones and geographic information systems , enables the collection of granular data on mosquito populations and their habitats, facilitating proactive control measures. Overall, these smart surveillance technologies offer a transformative advancement in vector control, enabling more precise and efficient interventions. However, their widespread adoption will require thorough evaluation of cost-effectiveness, scalability and adaptability across diverse settings. Conclusions: This review maps the evolution of smart mosquito surveillance over the past decade, highlighting AI-driven species identification, IoT-enabled real-time monitoring and the integration of remote sensing technologies. It provides a structured analysis of how these innovations improve mosquito detection and data accuracy. These insights can guide further research, inform practical implementations and shape policy decisions in public health and mosquito surveillance.
- Open Access
- 14 April 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (8) , 4311
Understanding Oxygen Concentrator Failures in Low Resource Settings: The Role of Dust and Humidity
Oxygen concentrators (OCs) are essential medical devices providing oxygen in various settings, especially low-resource settings (LRSs). Despite their adaptability and cost-effectiveness, challenges arise in such environments due to factors like dust, temperature, and humidity, leading to premature OC failure. While efforts have been made to address these issues, understanding the primary contributing factor remains unclear. This study aims to shed light on this matter through the analysis of exhausted zeolite samples from Uganda, Ethiopia, and South Africa alongside a commercial virgin sample. The samples were comprehensively characterized through powder X-ray diffraction (PXRD) analysis, wavelength dispersive X-ray fluorescence (WDXRF) elemental analysis, Brunauer–Emmett–Teller (BET) surface analysis, and thermo-gravimetric analysis (TGA) coupled with mass spectrometry (MS). The characterization results confirmed a low silicon X-type framework (FAU-LSX) for all the samples. The maximum mass loss during TGA tests occurred at 130–160 °C, suggesting that water is the main component released from the zeolites. This was confirmed by MS analysis, which revealed the predominance of water in all the sample matrices. A correlation was found between OC efficiency and the amount of water adsorbed by the zeolites, proving that humidity has a key role in causing OC malfunctioning. No evidence for the presence of dust as a contaminant in the zeolites was found by the absence of the expected chemical elements in WDXRF. Since the outcomes of the study are independent of the geographical origin of the zeolites, its findings provide general guidance for engineers to modify OCs and prevent zeolite moisture poisoning.
- 14 April 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (8) , 4311
Open AccessUnderstanding Oxygen Concentrator Failures in Low Resource Settings: The Role of Dust and Humidity
Oxygen concentrators (OCs) are essential medical devices providing oxygen in various settings, especially low-resource settings (LRSs). Despite their adaptability and cost-effectiveness, challenges arise in such environments due to factors like dust, temperature, and humidity, leading to premature OC failure. While efforts have been made to address these issues, understanding the primary contributing factor remains unclear. This study aims to shed light on this matter through the analysis of exhausted zeolite samples from Uganda, Ethiopia, and South Africa alongside a commercial virgin sample. The samples were comprehensively characterized through powder X-ray diffraction (PXRD) analysis, wavelength dispersive X-ray fluorescence (WDXRF) elemental analysis, Brunauer–Emmett–Teller (BET) surface analysis, and thermo-gravimetric analysis (TGA) coupled with mass spectrometry (MS). The characterization results confirmed a low silicon X-type framework (FAU-LSX) for all the samples. The maximum mass loss during TGA tests occurred at 130–160 °C, suggesting that water is the main component released from the zeolites. This was confirmed by MS analysis, which revealed the predominance of water in all the sample matrices. A correlation was found between OC efficiency and the amount of water adsorbed by the zeolites, proving that humidity has a key role in causing OC malfunctioning. No evidence for the presence of dust as a contaminant in the zeolites was found by the absence of the expected chemical elements in WDXRF. Since the outcomes of the study are independent of the geographical origin of the zeolites, its findings provide general guidance for engineers to modify OCs and prevent zeolite moisture poisoning.