Jayu Kalambe
Jayu Kalambe has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Sangeeta Palekar
Department of Electronics Engineering, Shri Ramdeobaba College of Engineering and Management, Nagpur, India
3 shared publications Abhijit Awasthi
Department of Electronics Engineering, Ramdeobaba University, Nagpur, Maharashtra, India
1 shared publicationArpita Parakh
Department of Biomedical Engineering, Ramdeobaba University Nagpur, Nagpur, India
1 shared publicationAyushh Khaire
Department of Electronics Engineering, Ramdeobaba University, Nagpur, Maharashtra, India
1 shared publication- Bidipta Rana
Department of Electronics Engineering, Ramdeobaba University, Nagpur, Maharashtra, India
1 shared publication - Danish Ahmad Khan
Department of Biomedical Engineering, Shri Ramdeobaba College of Engineering and Management Nagpur, Nagpur, India
1 shared publication
Latest Publications
- 17 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 10 (1) , 1-4
A Portable Microfluidic Paper-Based Analytical Device for Sensing of Cortisol in Artificial Saliva
Cortisol is a key stress hormone that regulates metabolism, immune response and various physiological functions including cardiovascular, respiratory, reproductive and musculoskeletal systems. Imbalances in cortisol levels can lead to severe health complications, emphasizing the need for continuous monitoring. This paper presents a novel, portable sensing platform for affordable and selective cortisol detection in artificial saliva. The system utilizes cost-effective, wax-printed micro-pads on paper-based substrates, forming a compact colorimetric sensor. By leveraging the blue tetrazolium (BT) reagent, it detects cortisol through a distinct and quantifiable color change. A 3D-printed black box serves as a controlled detection chamber, eliminating the need for bulky traditional devices. An ESP32 microcontroller processes data from an RGB sensor, precisely analyzing color changes on reagent-coated micropads for accurate cortisol quantification. A deep learning regression model deployed directly on the microcontroller, enhances detection accuracy by correlating color intensity with cortisol concentration. The detected cortisol levels are displayed on an OLED screen and sent to a smartphone via bluetooth for seamless storage, stress monitoring, and advanced analysis. Additionally, the system securely stores recorded data for long-term reference. Offering rapid detection within 10 minutes, the system achieves a detection limit (LOD) of 1 ng/mL, a wide detection range of 1– 800 ng/mL, and an R2 value of 0.96, ensuring high precision. This innovative, non-invasive, and user-friendly platform provides a reliable solution for stress monitoring and serves as a Point of Care (PoC) compatible sensing platform.
- 17 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 10 (1) , 1-4
A Portable Microfluidic Paper-Based Analytical Device for Sensing of Cortisol in Artificial Saliva
Cortisol is a key stress hormone that regulates metabolism, immune response and various physiological functions including cardiovascular, respiratory, reproductive and musculoskeletal systems. Imbalances in cortisol levels can lead to severe health complications, emphasizing the need for continuous monitoring. This paper presents a novel, portable sensing platform for affordable and selective cortisol detection in artificial saliva. The system utilizes cost-effective, wax-printed micro-pads on paper-based substrates, forming a compact colorimetric sensor. By leveraging the blue tetrazolium (BT) reagent, it detects cortisol through a distinct and quantifiable color change. A 3D-printed black box serves as a controlled detection chamber, eliminating the need for bulky traditional devices. An ESP32 microcontroller processes data from an RGB sensor, precisely analyzing color changes on reagent-coated micropads for accurate cortisol quantification. A deep learning regression model deployed directly on the microcontroller, enhances detection accuracy by correlating color intensity with cortisol concentration. The detected cortisol levels are displayed on an OLED screen and sent to a smartphone via bluetooth for seamless storage, stress monitoring, and advanced analysis. Additionally, the system securely stores recorded data for long-term reference. Offering rapid detection within 10 minutes, the system achieves a detection limit (LOD) of 1 ng/mL, a wide detection range of 1– 800 ng/mL, and an R2 value of 0.96, ensuring high precision. This innovative, non-invasive, and user-friendly platform provides a reliable solution for stress monitoring and serves as a Point of Care (PoC) compatible sensing platform.
- 11 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 10 (1) , 1-4
Nanostructured Silicon Aptasensor for Reliable Detection of Leukemia Biomarker
A silicon-based chemiresistive aptasensor was developed for sensitive detection of acute lymphoblastic leukemia (ALL). Using techniques of photolithography and sputtering, interdigitated electrodes (IDEs) having finger spacing of 25 μm and dimensions of 3.4 mm × 2.93 mm were fabricated. The sensing surface was functionalized step-by-step with reduced graphene oxide (rGO) and the Sgc8c aptamer for selective target recognition. The sensor demonstrated a significant decrease in resistance upon hybridization with the complementary DNA sequence. Quantitative analysis confirmed, a limit of detection of 6 nM, a broad linear range from 1 nM to 100 μM, a sensitivity of 15.122% per decade and a strong linear correlation R2 = 0.9566. The aptasensor also demonstrated clear specificity against noncomplementary strands and glucose, along with reliable reusability of IDE hardware through repeated functionalization of the IDE platform. These findings highlight the sensor’s potential for precise, real-time detection of leukemia associated DNA sequences.
- 11 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 10 (1) , 1-4
Nanostructured Silicon Aptasensor for Reliable Detection of Leukemia Biomarker
A silicon-based chemiresistive aptasensor was developed for sensitive detection of acute lymphoblastic leukemia (ALL). Using techniques of photolithography and sputtering, interdigitated electrodes (IDEs) having finger spacing of 25 μm and dimensions of 3.4 mm × 2.93 mm were fabricated. The sensing surface was functionalized step-by-step with reduced graphene oxide (rGO) and the Sgc8c aptamer for selective target recognition. The sensor demonstrated a significant decrease in resistance upon hybridization with the complementary DNA sequence. Quantitative analysis confirmed, a limit of detection of 6 nM, a broad linear range from 1 nM to 100 μM, a sensitivity of 15.122% per decade and a strong linear correlation R2 = 0.9566. The aptasensor also demonstrated clear specificity against noncomplementary strands and glucose, along with reliable reusability of IDE hardware through repeated functionalization of the IDE platform. These findings highlight the sensor’s potential for precise, real-time detection of leukemia associated DNA sequences.
- 30 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 9 (12) , 1-4
Smartphone-Based Portable Calcium-Sensing Platform Using Image Processing and Machine Learning
Monitoring serum calcium levels is essential, as deviation from normal levels can disrupt body functions and can cause severe health issues. Due to the high prevalence of calcium-related disorders in India, there is an urgent need for the development of low-cost, portable, easily accessible calcium testing devices that enable early detection and timely treatment. To address the issue, this study presents a portable calcium-sensing device that combines principles of colorimetric chemistry, image processing, and machine learning to measure calcium concentration. The proposed device uses the Arsenazo III reagent, which changes color from blue to purple on an increase in calcium concentration. The sensing platform is designed as a custom 3-D-printed controlled light enclosure for capturing reproducible and consistent images of Arsenazo III-calcium solutions. For calcium measurement, color features were extracted from multiple color space models (red, green, and blue; hue, saturation, value; and Lab), and then these features were mapped to calcium concentrations using supervised regression algorithms. Feature selection was applied to identify the three most effective predictors, which simplified the model without affecting accuracy. By evaluating various models with standard metrics, it was found that ensemble-based models, particularly random forest (R2 = 0.9979) and gradient boosting (R2 = 0.9962), performed better than other models. The developed calcium-sensing platform is highly sensitive, capable of detecting calcium levels as low as 1 mg/dL (limit of detection), and works effectively across a clinically relevant range of 1–20 mg/dL. Validation tests were also performed comparing the proposed device with a commercial biochemistry analyzer. These tests showed strong agreement, confirming the potential of the proposed system for accurate calcium prediction.
- 30 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 9 (12) , 1-4
Smartphone-Based Portable Calcium-Sensing Platform Using Image Processing and Machine Learning
Monitoring serum calcium levels is essential, as deviation from normal levels can disrupt body functions and can cause severe health issues. Due to the high prevalence of calcium-related disorders in India, there is an urgent need for the development of low-cost, portable, easily accessible calcium testing devices that enable early detection and timely treatment. To address the issue, this study presents a portable calcium-sensing device that combines principles of colorimetric chemistry, image processing, and machine learning to measure calcium concentration. The proposed device uses the Arsenazo III reagent, which changes color from blue to purple on an increase in calcium concentration. The sensing platform is designed as a custom 3-D-printed controlled light enclosure for capturing reproducible and consistent images of Arsenazo III-calcium solutions. For calcium measurement, color features were extracted from multiple color space models (red, green, and blue; hue, saturation, value; and Lab), and then these features were mapped to calcium concentrations using supervised regression algorithms. Feature selection was applied to identify the three most effective predictors, which simplified the model without affecting accuracy. By evaluating various models with standard metrics, it was found that ensemble-based models, particularly random forest (R2 = 0.9979) and gradient boosting (R2 = 0.9962), performed better than other models. The developed calcium-sensing platform is highly sensitive, capable of detecting calcium levels as low as 1 mg/dL (limit of detection), and works effectively across a clinically relevant range of 1–20 mg/dL. Validation tests were also performed comparing the proposed device with a commercial biochemistry analyzer. These tests showed strong agreement, confirming the potential of the proposed system for accurate calcium prediction.
- 14 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (10) , 18155-18162
Microfluidic Paper-Based Portable Biochemistry Analyzer for Blood Parameter Sensing
A compact, portable, paper-based biochemistry analyzer has been developed for cost-effective, point-of-care blood parameter analysis. The device employs wax-printed paper-based microchannels (μpads) coated with specific reagents to detect critical blood parameters. It analyzes blood serum for sugar, proteins, enzymes, electrolytes, and lipids, aiding in diagnosing, monitoring, and treating various medical conditions. A 3D printed device is designed that houses a multi-spectral sensor (AS7341) interfaced with an ESP32 microcontroller measures absorbed light to analyze concentration in real time. To validate the performance of the developed device, various parameters including albumin, creatinine, urea, triglycerides, total protein, and glucose are tested. The μpads allow precise detection using a minimal sample volume of 100 μL, making it especially suitable for low-resource settings. Additionally, the linear range for respective analytes is: albumin up to 8 g/dl, creatinine up to 20 mg/dl, triglycerides up to 1000 mg/dl, total protein up to 15 g/dl, and glucose up to 600 mg/dl, with corresponding limits of detection (LOD) at 0.134 g/dl, 0.087 mg/dl, 0.055 mg/dl, 0.094 g/dl, and 0.095 mg/dl, respectively. The portable design, combined with its ease of use and low-cost components, makes this analyzer a practical solution for point-of-care diagnostics, particularly in remote or underserved regions where conventional laboratory equipment is impractical due to size, cost, and operational requirements. By overcoming the limitations of traditional bulky analyzers, this device has the potential to significantly enhance accessibility to biochemical diagnostics in healthcare.
- 14 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (10) , 18155-18162
Microfluidic Paper-Based Portable Biochemistry Analyzer for Blood Parameter Sensing
A compact, portable, paper-based biochemistry analyzer has been developed for cost-effective, point-of-care blood parameter analysis. The device employs wax-printed paper-based microchannels (μpads) coated with specific reagents to detect critical blood parameters. It analyzes blood serum for sugar, proteins, enzymes, electrolytes, and lipids, aiding in diagnosing, monitoring, and treating various medical conditions. A 3D printed device is designed that houses a multi-spectral sensor (AS7341) interfaced with an ESP32 microcontroller measures absorbed light to analyze concentration in real time. To validate the performance of the developed device, various parameters including albumin, creatinine, urea, triglycerides, total protein, and glucose are tested. The μpads allow precise detection using a minimal sample volume of 100 μL, making it especially suitable for low-resource settings. Additionally, the linear range for respective analytes is: albumin up to 8 g/dl, creatinine up to 20 mg/dl, triglycerides up to 1000 mg/dl, total protein up to 15 g/dl, and glucose up to 600 mg/dl, with corresponding limits of detection (LOD) at 0.134 g/dl, 0.087 mg/dl, 0.055 mg/dl, 0.094 g/dl, and 0.095 mg/dl, respectively. The portable design, combined with its ease of use and low-cost components, makes this analyzer a practical solution for point-of-care diagnostics, particularly in remote or underserved regions where conventional laboratory equipment is impractical due to size, cost, and operational requirements. By overcoming the limitations of traditional bulky analyzers, this device has the potential to significantly enhance accessibility to biochemical diagnostics in healthcare.