Ziyang Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ziyang Liu has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Dagui Wang
School of Mechanical and Electrical Engineering, Anhui Jianzhu University, Hefei, Anhui, China
1 shared publication - Lei Huang
School of Mechanical and Electrical Engineering, Anhui Jianzhu University, Hefei 230601, China
1 shared publication - Liai Chen
School of Mechanical and Electrical Engineering, Anhui Jianzhu University, Hefei, Anhui, China
1 shared publication - Qian Zhang
School of Mechanical and Electrical Engineering, Anhui Jianzhu University, Hefei 230601, China
1 shared publication - Song Chen
School of Mechanical and Electrical Engineering, Anhui Jianzhu University, Hefei 230601, China
1 shared publication - Yuhan Xu
School of Mechanical and Electrical Engineering, Anhui Jianzhu University, Hefei 230601, China
1 shared publication
Latest Publications
- Open Access
Study on the Mechanism of High-Pressure Spraying of Water-Based Release Agent by External Mixing
In the casting and stamping process of automobile, ship, aerospace, and other fields, improving the atomization quality of the spray release agent can effectively solve the problems of difficult film removal, low efficiency, and poor surface finish, and greatly improve the efficiency of production and manufacturing. The geometric model of the external mixing nozzle was constructed, and the calculation domain and grid were divided. The atomization flow field velocity, liquid film thickness, particle distribution, and cooling amount were calculated using fluid simulation software. Finally, an experimental platform was set up for verification. With the increase in the distance between the iron plate and the nozzle, the velocity of the flow field decreases from the nozzle exit to the periphery, and the frequency distribution of D60–70 increases gradually. With the increase in the pressure ratio (K), the particle velocity increases gradually, the liquid film thickness increases first, and then gently decreases, and the D60–70 frequency distribution decreases. The influence of gas pressure on atomized particle velocity and liquid film thickness is greater than that of liquid phase pressure, and the ion velocity reaches the peak value when K = 2. When K = 1.5, the average thickness increment of absolute liquid film is small, the atomized particle diameter changes the least, the frequency distribution of D65 particles is approximately the same, and the atomization effect is the most stable. When the spraying time is 1 s, the K value is larger, and the smaller the temperature drop will be. In 2–4 s, the change in K value has little influence on the cooling amount.
Open AccessStudy on the Mechanism of High-Pressure Spraying of Water-Based Release Agent by External Mixing
In the casting and stamping process of automobile, ship, aerospace, and other fields, improving the atomization quality of the spray release agent can effectively solve the problems of difficult film removal, low efficiency, and poor surface finish, and greatly improve the efficiency of production and manufacturing. The geometric model of the external mixing nozzle was constructed, and the calculation domain and grid were divided. The atomization flow field velocity, liquid film thickness, particle distribution, and cooling amount were calculated using fluid simulation software. Finally, an experimental platform was set up for verification. With the increase in the distance between the iron plate and the nozzle, the velocity of the flow field decreases from the nozzle exit to the periphery, and the frequency distribution of D60–70 increases gradually. With the increase in the pressure ratio (K), the particle velocity increases gradually, the liquid film thickness increases first, and then gently decreases, and the D60–70 frequency distribution decreases. The influence of gas pressure on atomized particle velocity and liquid film thickness is greater than that of liquid phase pressure, and the ion velocity reaches the peak value when K = 2. When K = 1.5, the average thickness increment of absolute liquid film is small, the atomized particle diameter changes the least, the frequency distribution of D65 particles is approximately the same, and the atomization effect is the most stable. When the spraying time is 1 s, the K value is larger, and the smaller the temperature drop will be. In 2–4 s, the change in K value has little influence on the cooling amount.