Ahmet Sarı
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ahmet Sarı has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
- Huseyin Eristi
MERSİN ÜNİVERSİTESİ, MÜHENDİSLİK FAKÜLTESİ
2 shared publications - Ali Akdagli
Mersin Universitesi
1 shared publication - Elif Baldan
MERSİN ÜNİVERSİTESİ, MÜHENDİSLİK FAKÜLTESİ
1 shared publication
Latest Publications
- Open Access
- 2 July 2025
- Published by Cukurova Universitesi Muhendislik-Mimarlik Fakultesi Dergisi in Çukurova Üniversitesi Mühendislik Fakültesi Dergisi
- Vol. 40 (2) , 301-311
Investigation of Panel Efficiency in Photovoltaic Systems Under Partial Shading and Different Pollution Conditions: An Experimental Study
PV systems are very important to ensure the efficient operation of photovoltaic (PV) systems in electricity generation. However, environmental conditions or degradation of the panels affect this production. In this paper, in order to investigate the factors affecting the efficiency, the surface temperature under full irradiation and partial shading conditions is measured with a thermal camera and analyses are performed. According to pollution levels, the panels are classified as defective and healthy in two different conditions and characteristic curves of PV panels are generated. According to the experimental results, it is observed that in both full irradiation and partial shading conditions, the clean panel washed with water produces more power than the other panels and the surface temperatures are at the optimum level. This study shows that regular cleaning of PV panels and detection of panel defects by thermal imaging camera are beneficial to increase the efficiency.
- 2 July 2025
- Published by Cukurova Universitesi Muhendislik-Mimarlik Fakultesi Dergisi in Çukurova Üniversitesi Mühendislik Fakültesi Dergisi
- Vol. 40 (2) , 301-311
Open AccessInvestigation of Panel Efficiency in Photovoltaic Systems Under Partial Shading and Different Pollution Conditions: An Experimental Study
PV systems are very important to ensure the efficient operation of photovoltaic (PV) systems in electricity generation. However, environmental conditions or degradation of the panels affect this production. In this paper, in order to investigate the factors affecting the efficiency, the surface temperature under full irradiation and partial shading conditions is measured with a thermal camera and analyses are performed. According to pollution levels, the panels are classified as defective and healthy in two different conditions and characteristic curves of PV panels are generated. According to the experimental results, it is observed that in both full irradiation and partial shading conditions, the clean panel washed with water produces more power than the other panels and the surface temperatures are at the optimum level. This study shows that regular cleaning of PV panels and detection of panel defects by thermal imaging camera are beneficial to increase the efficiency.
- Open Access
- 15 April 2025
- Published by Omer Halisdemir Universitesi in Ömer Halisdemir Üniversitesi Mühendislik Bilimleri Dergisi
- Vol. 14 (2) , 630-641
Investigation the effects of photovoltaic systems on electricity distribution networks and determining the optimum network structure
Distributed generation models have started to be seen intensively in distribution networks with technological developments. The increase in distributed generation resources has brought changes in the grid. Problems such as improper operation of grid protection systems and imbalances in load flow have emerged. In this article, short circuit and load flow analyses of a low voltage distribution network with a distributed generation source are performed and the effects on the network are predicted. Results and predictions regarding the optimum operating conditions of distribution networks in the presence of distributed generation resources have been obtained. Real-time analyses are performed with a power quality measurement device. Scenarios are created in different situations in the presence of distributed generation resources. These scenarios are analysed using a network simulation program. The simulation programme analysed the effects of seasonal conditions and changes in power generation and loads on distribution transformers. In the light of the data obtained, the changes that are required to be made in the inventories in the network topology considering the changes in energy generation time and voltage levels outside the energy generation time are specified. Applications such as automatic tap switching of distribution transformers after a certain power level are proposed.
- 15 April 2025
- Published by Omer Halisdemir Universitesi in Ömer Halisdemir Üniversitesi Mühendislik Bilimleri Dergisi
- Vol. 14 (2) , 630-641
Open AccessInvestigation the effects of photovoltaic systems on electricity distribution networks and determining the optimum network structure
Distributed generation models have started to be seen intensively in distribution networks with technological developments. The increase in distributed generation resources has brought changes in the grid. Problems such as improper operation of grid protection systems and imbalances in load flow have emerged. In this article, short circuit and load flow analyses of a low voltage distribution network with a distributed generation source are performed and the effects on the network are predicted. Results and predictions regarding the optimum operating conditions of distribution networks in the presence of distributed generation resources have been obtained. Real-time analyses are performed with a power quality measurement device. Scenarios are created in different situations in the presence of distributed generation resources. These scenarios are analysed using a network simulation program. The simulation programme analysed the effects of seasonal conditions and changes in power generation and loads on distribution transformers. In the light of the data obtained, the changes that are required to be made in the inventories in the network topology considering the changes in energy generation time and voltage levels outside the energy generation time are specified. Applications such as automatic tap switching of distribution transformers after a certain power level are proposed.