DWDilani Neranjana Wimalarathne

Dilani Neranjana Wimalarathne

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Dilani Neranjana Wimalarathne has a total of 15 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Identification of factors affecting the retention of 99mTc-DMSA in syringes among the paediatric population in Sri Lanka

    by U. H. V. Paramee, B. E. S. Jayasooriya, C. S. Wijesinghe, D. D. N. Wimalarathne, P. D. T. Pathirana, N. Samarasinghe, S. I. D. Silva, J. M. C. Udugama

    Background: 99mTc-DMSA is a common paediatric renal scintigraphystudy, where radiopharmaceutical is introduced intravenously usingdisposable syringes. Radiopharmaceuticals can be retained on disposablesyringes, causing under-dosing, and impacting imaging quality inpaediatric patients. The study aimed to specify the factors affecting onretention of 99mTc-DMSA in disposable syringes. Furthermore, theinfluence of the medical staff, patient positioning, and the ascendancy ofthe MON.TEK 99mMo/99mTc generator were investigated.Methods: A study of 212 paediatric patients undergoing 99mTc-DMSA renalscintigraphy was conducted using CAPINTEC-CRC-15R and CAPINTEC-CRC/15 BETA radiation dose calibrators. The 99mTc-Pertechnetate waseluted with a MON.TEK 99mMo/99mTc generator and the radio-pharmaceutical volume were recorded. Six types of 1ml/1cc disposablesyringes (Types 1-6) and one 1ml insulin syringe (Type 7) were used. Pre-and post-doses of these syringes were measured.he administered activityvalue was considered to develop DRL.Results: Results showed a significant moderate, positive correlationbetween retention dose and dilution (radiopharmaceutical volume). Therewas no correlation between retention dose and pre-dose or patient weight.No significant difference in retention was found based on patient genderor position. Significant differences in retention dose were observed amongsyringe types, injection sites, labeling personnel, and administeringpersonnel.Conclusion: Retention of 99mTc-DMSA varies by syringe type, withType-1 syringes showing the highest retention and Type-7 the lowest,making Type-7 the most suitable. Retention is influenced byradiopharmaceutical dilution, labeling, injecting personnel, and injectionsite, while pre-dose, patient gender, weight, positioning, and decay timehave no significant effect. This highlights the importance of syringeselection and standardizing procedures to minimize retention, improvedosing accuracy, and enhance imaging quality.

  • Open Access

    Quantitative Research of 11C-CFT and 18F-FDG PET in Parkinson’s Disease: A Pilot Study With NeuroQ Software

    by Xun Sun, Fang Liu, Qingyao Liu, Yongkang Gai, Weiwei Ruan, Dilani Neranjana Wimalarathne, Fan Hu, Xubo Tan, Xiaoli Lan

    Dopamine transporter (DAT) and glucose metabolism imaging have been applied in the diagnosis of Parkinson’s disease (PD). We explored the possibility of evaluating for PD with NeuroQ software by analyzing 11C-2β-carbomethoxy-3β-(4-fluorophenyl) tropane (11C-CFT) and 18F-FDG PET/CT. We retrospectively analyzed brain 11C-CFT and 18F-FDG PET/CT of 38 patients with parkinsonism, including 20 with PD, 10 with multiple system atrophy (MSA) and 8 with essential tremor (ET), and compared them with the PET/CT of 11 normal healthy controls (NC). PD patients were divided into mild and moderate-severe grade according to the Hoehn-Yahr (H&Y) scale. The 11C-CFT uptake in the caudate nuclei (CN) and putamen (Pu) normalized with cerebellum (CN/Cb and Pu/Cb) were obtained with a manual method and NeuroQ software, and their diagnostic performance was compared.18F-FDG uptake of specific regions was also obtained with NeuroQ, and the enhancement effect for the differential diagnosis was evaluated. There was significant agreement between the manual method and the NeuroQ method for 11C-CFT uptake by CN (r2= 0.680) and Pu (r2= 0.770). 11C-CFT uptake by CN and Pu in PD and MSA patients was significantly lower compared to NC and ET patients. The cutoffs of CN/Cb and Pu/Cb for the distinction between PD and NC were 1.71 and 2.20, respectively. No difference in uptake ratios occurred between PD and MSA. 18F-FDG uptake by the pons and cerebellum in the MSA group was markedly decreased. It was highly accurate in distinguishing between PD and MSA when combined with analysis of 11C-CFT uptake. Pu/Cb decreased significantly in mild grade PD compared to NC group (1.92 ± 0.33 vs. 2.82 ± 0.43); however no statistically significant decrease in CN/Cb was observed until moderate-severe grade PD (1.43 ± 0.11 vs. 2.23 ± 0.36). In early asymmetric PD, a statistically significant difference could be seen with Pu/Cb between the symptomatic and asymptomatic side (2.17 ± 0.30 vs. 1.95 ± 0.22). 11C-CFT and 18F-FDG PET/CT can be analyzed quantitatively with NeuroQ software, which provides an accurate method for the diagnosis and severity evaluation of PD.