PZPeng Zhou

Peng Zhou

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Peng Zhou has a total of 17 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Calibration of a gated neutron time-of-flight spectrometer with low-afterglow

    by X. Su, P. Zhou, J. L. Li, J. F. Ma, D. W. Yuan, Z. Zhang, G. Q. Zhang, K. N. Li, P. Chen, F. Y. Wu, et al.

    Neutron Time-of-Flight (nTOF) detectors are key diagnostics to detect thermonuclear neutrons in laser-fusion experiments. This diagnostic, however, is often plagued by strong gamma-ray noise prior to neutron signals, especially in harsh fast-ignition (FI) environments. To address this issue, a combination of low-afterglow liquid scintillators with time-gated photomultiplier tubes as necessary nTOF components would be a natural solution. However, the calibration of such detectors is challenging due to low detection efficiency and low neutron yield in FI experiments. In this paper, we propose a novel method to cross-calibrate a gated low-afterglow nTOF spectrometer using a pre-calibrated traditional non-gated nTOF spectrometer. This approach was demonstrated using neutrons from counter-streaming deuterated-polystyrene plasmas driven by the ShenGuang-II (SG-II) laser facility, with neutron yields ranging from 4 × 105 to 1 × 107. By implementing this calibration method, we anticipate a significant improvement in the accuracy of neutron detection within a 10% uncertainty for double-cone ignition experiments.


  • A two-dimensional imaging enabled x-ray streak camera system

    by Haochen Gu, Xu Zhao, Shan Wei, Peng Zhou, Qiang Zhou, Xiangyan Xu, Xiaohui Yuan, Zhe Zhang, Yutong Li, Jie Zhang

    Streak cameras are powerful tools that provide high temporal resolution by capturing one-dimensional images with slitted photocathodes while sacrificing the two-dimensional spatial information. A two-dimensional imaging enabled x-ray streak camera system has been developed to acquire the two-dimensional images in situ, with 27 μm spatial resolution and 150 ps time resolution. By attaching a scintillator plate in front of the cathode, x-ray emissions beyond the cathode slit are converted into visible light and recorded by an imaging camera. The simultaneous measurement of one-dimensional time-resolved and two-dimensional time-integrated images in the laser fusion experiment has demonstrated the benefits of the endoscope. Such a system could greatly extend the uses of traditional x-ray streak cameras.