Peng Zhou
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Peng Zhou has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Jie Zhang
Shanghai Jiao Tong University
2 shared publications - Xiaohui Yuan
Shanghai Jiao Tong University
2 shared publications - Zhe Zhang
Institute of Physics
2 shared publications - Dawei Yuan
National Astronomical Observatories, Chinese Academy of Sciences, Beijing 100101, China
1 shared publication F. Y. Wu
Key Laboratory for Laser Plasmas (MoE) and School of Physics and Astronomy, Shanghai Jiao Tong University 1 , Shanghai
1 shared publication- Guo-Qiang Zhang
Shanghai Advanced Research Institute, Chinese Academy of Sciences, Shanghai, China
1 shared publication
Latest Publications
- 1 September 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (9)
Calibration of a gated neutron time-of-flight spectrometer with low-afterglow
Neutron Time-of-Flight (nTOF) detectors are key diagnostics to detect thermonuclear neutrons in laser-fusion experiments. This diagnostic, however, is often plagued by strong gamma-ray noise prior to neutron signals, especially in harsh fast-ignition (FI) environments. To address this issue, a combination of low-afterglow liquid scintillators with time-gated photomultiplier tubes as necessary nTOF components would be a natural solution. However, the calibration of such detectors is challenging due to low detection efficiency and low neutron yield in FI experiments. In this paper, we propose a novel method to cross-calibrate a gated low-afterglow nTOF spectrometer using a pre-calibrated traditional non-gated nTOF spectrometer. This approach was demonstrated using neutrons from counter-streaming deuterated-polystyrene plasmas driven by the ShenGuang-II (SG-II) laser facility, with neutron yields ranging from 4 × 105 to 1 × 107. By implementing this calibration method, we anticipate a significant improvement in the accuracy of neutron detection within a 10% uncertainty for double-cone ignition experiments.
- 1 September 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (9)
Calibration of a gated neutron time-of-flight spectrometer with low-afterglow
Neutron Time-of-Flight (nTOF) detectors are key diagnostics to detect thermonuclear neutrons in laser-fusion experiments. This diagnostic, however, is often plagued by strong gamma-ray noise prior to neutron signals, especially in harsh fast-ignition (FI) environments. To address this issue, a combination of low-afterglow liquid scintillators with time-gated photomultiplier tubes as necessary nTOF components would be a natural solution. However, the calibration of such detectors is challenging due to low detection efficiency and low neutron yield in FI experiments. In this paper, we propose a novel method to cross-calibrate a gated low-afterglow nTOF spectrometer using a pre-calibrated traditional non-gated nTOF spectrometer. This approach was demonstrated using neutrons from counter-streaming deuterated-polystyrene plasmas driven by the ShenGuang-II (SG-II) laser facility, with neutron yields ranging from 4 × 105 to 1 × 107. By implementing this calibration method, we anticipate a significant improvement in the accuracy of neutron detection within a 10% uncertainty for double-cone ignition experiments.
- 1 April 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (4)
A two-dimensional imaging enabled x-ray streak camera system
Streak cameras are powerful tools that provide high temporal resolution by capturing one-dimensional images with slitted photocathodes while sacrificing the two-dimensional spatial information. A two-dimensional imaging enabled x-ray streak camera system has been developed to acquire the two-dimensional images in situ, with 27 μm spatial resolution and 150 ps time resolution. By attaching a scintillator plate in front of the cathode, x-ray emissions beyond the cathode slit are converted into visible light and recorded by an imaging camera. The simultaneous measurement of one-dimensional time-resolved and two-dimensional time-integrated images in the laser fusion experiment has demonstrated the benefits of the endoscope. Such a system could greatly extend the uses of traditional x-ray streak cameras.
- 1 April 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (4)
A two-dimensional imaging enabled x-ray streak camera system
Streak cameras are powerful tools that provide high temporal resolution by capturing one-dimensional images with slitted photocathodes while sacrificing the two-dimensional spatial information. A two-dimensional imaging enabled x-ray streak camera system has been developed to acquire the two-dimensional images in situ, with 27 μm spatial resolution and 150 ps time resolution. By attaching a scintillator plate in front of the cathode, x-ray emissions beyond the cathode slit are converted into visible light and recorded by an imaging camera. The simultaneous measurement of one-dimensional time-resolved and two-dimensional time-integrated images in the laser fusion experiment has demonstrated the benefits of the endoscope. Such a system could greatly extend the uses of traditional x-ray streak cameras.