Alamelu Chandrasekaran
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Alamelu Chandrasekaran has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
Asmae El Ganbour
Selux Diagnostics
1 shared publication- Eric Stern
Selux Diagnostics
1 shared publication - Gregory J. Berry
Department of Pathology and Cell Biology, Columbia University Irving Medical Center
1 shared publication Jacqueline Pento
Northwell Heath
1 shared publicationJill Lindley
Element Iowa City (JMI Laboratories)
1 shared publicationJingzi Sherman
Selux Diagnostics
1 shared publication
Latest Publications
- Open Access
- 14 May 2025
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 63 (5) , e0181924
Multi-center evaluation of the Selux next-generation phenotyping system for gram-negative direct-from-positive blood culture antimicrobial susceptibility testing
Accurate and rapid antimicrobial susceptibility test (AST) results from positive blood cultures are crucial for patient care and combatting antimicrobial resistance. Although recent advancements in rapid direct-from-positive blood culture (PBC) identification platforms have enabled the provision of species-level identification and some resistance marker information within hours after blood culture positivity, AST results required for clinical decision-making often require 48 h after blood culture positivity. This study evaluated the Selux next-generation phenotyping system, including an automated PBC Separator and the Selux AST system in a multicenter clinical trial for their ability to perform AST directly from PBCs for gram-negative bacilli. The PBC separator produces McFarland equivalent inocula from positive blood cultures within 1 h, facilitating direct processing on the Selux AST system. The study evaluated 162 fresh clinical PBC samples, 307 seeded clinical samples, and 87 seeded challenge samples across 4 sites for each of the 17 antimicrobials included in the panel. The results demonstrate that the Selux system’s clinical performance, reproducibility, and analytical performances are consistent when using positive blood cultures held for up to 16 h after positivity on the BACTEC and BacT/ALERT 3D and BacT/ALERT VIRTUO blood culture systems, including all major BACTEC and BacT/ALERT blood culture bottle types. These findings suggest that the PBC Separator with the Selux AST system is a valuable addition to the arsenal of tools available for rapid sepsis diagnosis and management. IMPORTANCE: Technologies that consistently and substantially shorten the time between blood bottle positivity, organism identification, and complete AST results are crucial for ensuring that antimicrobial therapy can be tailored. The Selux PBC Separator and the Selux AST system perform rapid AST directly from positive blood culture bottles. This substantially shortens the gap between obtaining a positive blood bottle and organism identification and the availability of a fully actionable AST result.
- 14 May 2025
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 63 (5) , e0181924
Open AccessMulti-center evaluation of the Selux next-generation phenotyping system for gram-negative direct-from-positive blood culture antimicrobial susceptibility testing
Accurate and rapid antimicrobial susceptibility test (AST) results from positive blood cultures are crucial for patient care and combatting antimicrobial resistance. Although recent advancements in rapid direct-from-positive blood culture (PBC) identification platforms have enabled the provision of species-level identification and some resistance marker information within hours after blood culture positivity, AST results required for clinical decision-making often require 48 h after blood culture positivity. This study evaluated the Selux next-generation phenotyping system, including an automated PBC Separator and the Selux AST system in a multicenter clinical trial for their ability to perform AST directly from PBCs for gram-negative bacilli. The PBC separator produces McFarland equivalent inocula from positive blood cultures within 1 h, facilitating direct processing on the Selux AST system. The study evaluated 162 fresh clinical PBC samples, 307 seeded clinical samples, and 87 seeded challenge samples across 4 sites for each of the 17 antimicrobials included in the panel. The results demonstrate that the Selux system’s clinical performance, reproducibility, and analytical performances are consistent when using positive blood cultures held for up to 16 h after positivity on the BACTEC and BacT/ALERT 3D and BacT/ALERT VIRTUO blood culture systems, including all major BACTEC and BacT/ALERT blood culture bottle types. These findings suggest that the PBC Separator with the Selux AST system is a valuable addition to the arsenal of tools available for rapid sepsis diagnosis and management. IMPORTANCE: Technologies that consistently and substantially shorten the time between blood bottle positivity, organism identification, and complete AST results are crucial for ensuring that antimicrobial therapy can be tailored. The Selux PBC Separator and the Selux AST system perform rapid AST directly from positive blood culture bottles. This substantially shortens the gap between obtaining a positive blood bottle and organism identification and the availability of a fully actionable AST result.