R. R. Boyko
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
R. R. Boyko has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Liliia Khvostivska
Тернопільський національний технічний університет імені Івана Пулюя
2 shared publications - Mykola Khvostivskyi
Ternopil Ivan Puluj National Technical University
2 shared publications - I. M. Pankiv
Тернопільський національний технічний університет імені Івана Пулюя, м. Тернопіль
1 shared publication - O. V. Fuch
Тернопільський національний технічний університет імені Івана Пулюя
1 shared publication - Vitalii Kartashov
Тернопільський національний технічний університет імені Івана Пулюя, м. Тернопіль
1 shared publication - Василь Дунець
Тернопільський національний технічний університет імені Івана Пулюя
1 shared publication
Latest Publications
- Open Access
- 30 March 2023
- Published by Igor Sikorsky Kyiv Polytechnic Institute in Visnyk NTUU KPI Seriia - Radiotekhnika Radioaparatobuduvannia
- No. 91,p. 63-71
Method and Algorithm of Electroencephalographic Signals Processing in Computer Medical Diagnostic Systems for Human Psychoemotional Indicators Detection
The method and algorithm for electroencephalographic signals processing during psychoemotional stress are developed to increase the informativeness of computer medical diagnostic systems in order to detect temporal transitions between various psychoemotional states in people. The method and algorithm for electroencephalographic signals processing is based on a mathematical model in the form of a periodically correlated random process and the synphase processing method without taking into account the relationship between correlation components as psycho-emotional indicators of a human. Such the model and method provide detection of the appearance of changes in the temporal structure of the electroencephalographic signal based on the data of changes in the periodic component in the form of averaged correlation components obtained within time-shift windows, which quantitatively reflect psycho-emotional changes in a humanin stressful situations.It is found that during the period of background exposure, there is a gradual decrease in the power level of the averaged correlation components of the electroencephalographic signal, during the period of negative influence, there is an increase in power, and during the recovery period, there is a decrease in the power of the components in relation to the two previous impacts.Software are developed based on the synphase method for electroencephalographic signals processing during psycho-emotional stress in the Matlab software environment.
- 30 March 2023
- Published by Igor Sikorsky Kyiv Polytechnic Institute in Visnyk NTUU KPI Seriia - Radiotekhnika Radioaparatobuduvannia
- No. 91,p. 63-71
Open AccessMethod and Algorithm of Electroencephalographic Signals Processing in Computer Medical Diagnostic Systems for Human Psychoemotional Indicators Detection
The method and algorithm for electroencephalographic signals processing during psychoemotional stress are developed to increase the informativeness of computer medical diagnostic systems in order to detect temporal transitions between various psychoemotional states in people. The method and algorithm for electroencephalographic signals processing is based on a mathematical model in the form of a periodically correlated random process and the synphase processing method without taking into account the relationship between correlation components as psycho-emotional indicators of a human. Such the model and method provide detection of the appearance of changes in the temporal structure of the electroencephalographic signal based on the data of changes in the periodic component in the form of averaged correlation components obtained within time-shift windows, which quantitatively reflect psycho-emotional changes in a humanin stressful situations.It is found that during the period of background exposure, there is a gradual decrease in the power level of the averaged correlation components of the electroencephalographic signal, during the period of negative influence, there is an increase in power, and during the recovery period, there is a decrease in the power of the components in relation to the two previous impacts.Software are developed based on the synphase method for electroencephalographic signals processing during psycho-emotional stress in the Matlab software environment.
- Open Access
- 30 March 2021
- Published by Igor Sikorsky Kyiv Polytechnic Institute in Visnyk NTUU KPI Seriia - Radiotekhnika Radioaparatobuduvannia
- No. 84,p. 66-77
Software, mathematical and algorithmic tools for the computer electroencephalography system of humans epilepsy manifestations detecting
Mathematical, algorithmic and software have been developed as a part of a computer electroencephalographic system. It is based on a 24 hours processing of an EEG signal in a form of a piecewise random sequence of white noises and an additive mixture of harmonic functions with different frequencies for hidden epilepsy time zones detection. The method of epilepsy detecting is based on a procedure of covariance treatment using covariators with basic harmonic functions of frequencies in the range from f1 to f2 within the sliding window, which moves along a sample of values of the EEG signal lasting 24 hours. Based on the mathematical model and processing method, an algorithm and software have been developed for computer electroencephalographic systems using the MATLAB application package. According to the results of the EEG signal lasting 24 hours experimental data processing, it was found that at the time moments of epilepsy there is covariation average power increasing compared to time moments without epilepsy. Therefore, estimates of covariators EEG signal within 24 hours respond quantitatively to the manifestations of epilepsy. To verify the developed mathematical, algorithmic support and software there was generated a test signal in the form of the harmonic components sum in given time zones, (characteristic of the EEG signal) at the time of epilepsy, and white noise - in time zones without epilepsy. The results of the generated test signal processing confirmed the correctness of the detection of the areas of harmonic components appearance that induce the manifestation of epilepsy.
- 30 March 2021
- Published by Igor Sikorsky Kyiv Polytechnic Institute in Visnyk NTUU KPI Seriia - Radiotekhnika Radioaparatobuduvannia
- No. 84,p. 66-77
Open AccessSoftware, mathematical and algorithmic tools for the computer electroencephalography system of humans epilepsy manifestations detecting
Mathematical, algorithmic and software have been developed as a part of a computer electroencephalographic system. It is based on a 24 hours processing of an EEG signal in a form of a piecewise random sequence of white noises and an additive mixture of harmonic functions with different frequencies for hidden epilepsy time zones detection. The method of epilepsy detecting is based on a procedure of covariance treatment using covariators with basic harmonic functions of frequencies in the range from f1 to f2 within the sliding window, which moves along a sample of values of the EEG signal lasting 24 hours. Based on the mathematical model and processing method, an algorithm and software have been developed for computer electroencephalographic systems using the MATLAB application package. According to the results of the EEG signal lasting 24 hours experimental data processing, it was found that at the time moments of epilepsy there is covariation average power increasing compared to time moments without epilepsy. Therefore, estimates of covariators EEG signal within 24 hours respond quantitatively to the manifestations of epilepsy. To verify the developed mathematical, algorithmic support and software there was generated a test signal in the form of the harmonic components sum in given time zones, (characteristic of the EEG signal) at the time of epilepsy, and white noise - in time zones without epilepsy. The results of the generated test signal processing confirmed the correctness of the detection of the areas of harmonic components appearance that induce the manifestation of epilepsy.