Mingfeng Lu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Mingfeng Lu has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Yajing Pei
Department of Ophthalmology, Shanxi Eye Hospital Affiliated to Shanxi Medical University, Taiyuan, Shanxi, China
2 shared publications - Chuang Lin
Beijing Xianwei Medical Technology Company Ltd, Beijing, China
1 shared publication Ke Ma
1 shared publication- Ke Ma
Beijing TongRen Eye Center, Beijing TongRen Hospital, Capital Medical University, Beijing Ophthalmology and Visual Sciences Key Lab, Beijing Institute of Ophthalmology, Beijing, China
1 shared publication - Shaofeng Han
North China Electric Power University
1 shared publication - Yang Yang
School of Mechanical Engineering and Automation, Beihang University, Beijing, China
1 shared publication
Latest Publications
- 13 January 2026
- Published by Elsevier in Applied Soft Computing
- Vol. 190
MSMT-Net: Multi-scale multi-task network for capsular edge recognition and instrument segmentation of cataract surgery
- 13 January 2026
- Published by Elsevier in Applied Soft Computing
- Vol. 190
MSMT-Net: Multi-scale multi-task network for capsular edge recognition and instrument segmentation of cataract surgery
- 21 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-10
Identifying and Predicting Voluntary Peeling Force in Continuous Curvilinear Capsulorhexis Considering Species Differences
Handheld manipulator offers a feasible way to relieve the challenge of continuous curvilinear capsulorhexis (CCC) by controlling peeling force actively. The precise identification and prediction of voluntary peeling force (0-2 Hz) form the basis of force controller design. However, achieving this goal is limited by species differences (experimental validation: animal model, clinical surgery: in-vivo human). This paper proposes a framework to relieve this problem. The proposed framework consists of a wavelet-based process module and a prediction module based on Long Short-Term Memory (LSTM) and the Transformer’s encoder. Peeling force measured from ex-vivo pig eyes (no treatment, treat with 0.1% and 0.5% sodium hypochlorite), in-vivo rabbit eyes, and ex-vivo human lens are utilized to validate the proposed framework. Experimental results show that the root mean square (RMS) error of identification is 0.37 mN. The RMS error of prediction is 0.41 mN (Steady) and 0.87 mN (Sharp, prediction time: 50 ms), respectively. The RMS prediction error of ex-vivo human samples is 0.36 mN (Steady) and 1.05 mN (Sharp) even all training data comes from animal models.
- 21 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-10
Identifying and Predicting Voluntary Peeling Force in Continuous Curvilinear Capsulorhexis Considering Species Differences
Handheld manipulator offers a feasible way to relieve the challenge of continuous curvilinear capsulorhexis (CCC) by controlling peeling force actively. The precise identification and prediction of voluntary peeling force (0-2 Hz) form the basis of force controller design. However, achieving this goal is limited by species differences (experimental validation: animal model, clinical surgery: in-vivo human). This paper proposes a framework to relieve this problem. The proposed framework consists of a wavelet-based process module and a prediction module based on Long Short-Term Memory (LSTM) and the Transformer’s encoder. Peeling force measured from ex-vivo pig eyes (no treatment, treat with 0.1% and 0.5% sodium hypochlorite), in-vivo rabbit eyes, and ex-vivo human lens are utilized to validate the proposed framework. Experimental results show that the root mean square (RMS) error of identification is 0.37 mN. The RMS error of prediction is 0.41 mN (Steady) and 0.87 mN (Sharp, prediction time: 50 ms), respectively. The RMS prediction error of ex-vivo human samples is 0.36 mN (Steady) and 1.05 mN (Sharp) even all training data comes from animal models.