Filipe A C Oliveira
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Filipe A C Oliveira has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
C.B. Rosa
1 shared publication- David Guilherme Andriotto Gonçalves
Universidade de São Paulo, Brasil
1 shared publication - Diego Armando Cardona Cardenas
Clinics Hospital University of São Paulo Medical School
1 shared publication - Estela Ribeiro
Heart Institute (InCor), Clinics Hospital, University of São Paulo Medical School (HCFMUSP), São Paulo, SP, Brazil
1 shared publication - Felipe Meneguitti Dias
Instituto do Coração, Hospital das Clínicas HCFMUSP, Faculdade de Medicina, Universidade de São Paulo, Av. Dr. Enéas de Carvalho Aguiar, 44, Sao Paulo, São Paulo, 05403-000, Brazil, +551126615441
1 shared publication J.P.G. Abreu
Inst. of Electr. Syst. & Energy, Itajuba Fed. Univ., Brazil
1 shared publication
Latest Publications
- 22 April 2025
- Published by IOP Publishing in Physiological Measurement
- Vol. 46 (4) , 045007
Exploring the limitations of blood pressure estimation using the photoplethysmography signal
Objetive. Hypertension, a leading contributor to cardiovascular morbidity, underscores the need for accurate and continuous blood pressure (BP) monitoring. Photoplethysmography (PPG) emerges as a promising approach for continuous BP monitoring. However, the precision of BP estimates derived from PPG signals has been the subject of ongoing debate, requiring a comprehensive evaluation of their efficacy. This paper aims to provide the potentials and limitations regarding BP estimation from single-site PPG signals. Approach. We developed a calibration-based Siamese ResNet model for BP estimation. We compared the use of normalized PPG (N-PPG) against the normalized invasive arterial BP (N-IABP) signals as input. N-IABP signals, while not directly presenting systolic (SBP) and diastolic (DBP) BP values, are expected to offer more precise estimations than PPG since it is a direct pressure sensor inside the body. Thus, if N-IABP poses challenges in BP estimation, predicting BP from PPG signals might be even more challenging. Main results. Our evaluation, conducted using the AAMI and BHS standards on the VitalDB dataset, revealed that inference using N-IABP signals meet with AAMI standards for both SBP and DBP, with errors of 1.29 ± 6.33 mmHg for systolic pressure and 1.17 ± 5.78 for diastolic pressure. In contrast, N-PPG based inference exhibited inferior performance than N-IABP, presenting 1.49 ± 11.82 mmHg and 0.89 ± 7.27 mmHg for systolic and diastolic pressure respectively in their best setup. Significance. Our findings establish a critical benchmark for PPG performance, providing realistic expectations for its BP estimation capabilities. We concluded that while PPG signals contain BP-correlated information, they may not suffice for accurate prediction.
- 22 April 2025
- Published by IOP Publishing in Physiological Measurement
- Vol. 46 (4) , 045007
Exploring the limitations of blood pressure estimation using the photoplethysmography signal
Objetive. Hypertension, a leading contributor to cardiovascular morbidity, underscores the need for accurate and continuous blood pressure (BP) monitoring. Photoplethysmography (PPG) emerges as a promising approach for continuous BP monitoring. However, the precision of BP estimates derived from PPG signals has been the subject of ongoing debate, requiring a comprehensive evaluation of their efficacy. This paper aims to provide the potentials and limitations regarding BP estimation from single-site PPG signals. Approach. We developed a calibration-based Siamese ResNet model for BP estimation. We compared the use of normalized PPG (N-PPG) against the normalized invasive arterial BP (N-IABP) signals as input. N-IABP signals, while not directly presenting systolic (SBP) and diastolic (DBP) BP values, are expected to offer more precise estimations than PPG since it is a direct pressure sensor inside the body. Thus, if N-IABP poses challenges in BP estimation, predicting BP from PPG signals might be even more challenging. Main results. Our evaluation, conducted using the AAMI and BHS standards on the VitalDB dataset, revealed that inference using N-IABP signals meet with AAMI standards for both SBP and DBP, with errors of 1.29 ± 6.33 mmHg for systolic pressure and 1.17 ± 5.78 for diastolic pressure. In contrast, N-PPG based inference exhibited inferior performance than N-IABP, presenting 1.49 ± 11.82 mmHg and 0.89 ± 7.27 mmHg for systolic and diastolic pressure respectively in their best setup. Significance. Our findings establish a critical benchmark for PPG performance, providing realistic expectations for its BP estimation capabilities. We concluded that while PPG signals contain BP-correlated information, they may not suffice for accurate prediction.
- 6 April 2005
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 588-593
A software for voltage sags strategic studies
This work describes a software specially developed for strategic studies within power quality, more specifically voltage sags. First, the methodology to estimate the number and the characteristics of the disturbances is presented. Then, the software structure is briefly described. Finally, a case study is discussed.
- 6 April 2005
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 588-593
A software for voltage sags strategic studies
This work describes a software specially developed for strategic studies within power quality, more specifically voltage sags. First, the methodology to estimate the number and the characteristics of the disturbances is presented. Then, the software structure is briefly described. Finally, a case study is discussed.