Anna Hoyle
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Anna Hoyle has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Benjamin Metcalfe
University of Bath
1 shared publication - Dingguo Zhang
Department of Electronic and Electrical Engineering, University of Bath, Bath, U.K.
1 shared publication - Jonathan Graham-Harper-Cater
Electronic and Electrical Engineering, University of Bath, Electronic and Electrical Engineering, Claverton Down, Bath, Bath, BA2 7AY, UNITED KINGDOM OF GREAT BRITAIN AND NORTHERN IRELAND
1 shared publication - Leen Jabban
Electronic and Electrical Engineering, University of Bath, Electronic and Electrical Engineering, Claverton Down, Bath, Bath, BA2 7AY, UNITED KINGDOM OF GREAT BRITAIN AND NORTHERN IRELAND
1 shared publication - Nathan Routledge
Department of Electronic & Electrical Engineering, University of Bath, Claverton Down, BA2 7AY, Bath, United Kingdom; Bath Institute for the Augmented Human, University of Bath, Claverton Down, BA2 7AY, Bath, United Kingdom
1 shared publication - Nicos Hadjigeorgiou
Centre for Robotics Research (CORE) Department of Engineering King’s College London London UK
1 shared publication
Latest Publications
- Open Access
- 1 April 2025
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 22 (2) , 026044
The comfort of temporal interference stimulation on the forearm: computational and psychophysical evaluation
Objective. Transcutaneous electrical stimulation aims to restore sensation and function in individuals with sensory or motor deficits. However, limited selectivity and unintended nerve recruitment often result in discomfort. Temporal interference (TI) stimulation has been proposed as a novel approach to non-invasive nerve stimulation, hypothesising that low-frequency modulation of kilohertz carriers reduces activation thresholds. Prior studies have produced conflicting results regarding comfort in kilohertz-frequency stimulation, and the practical applicability of TI remains unclear. This study addresses these gaps by systematically analysing the role of depth of modulation in activation thresholds and comfort, focusing on peripheral nerves and clinically relevant stimulation levels. Approach. This study uses a dual-method approach combining computational and psychophysical experiments targeting the median nerve. Computational modelling involved nine magnetic resonance imaging-informed finite element models to account for anatomical variability and biophysical neural activation predictions using NEURON., test Psychophysical experiments with 19 participants determined stimulation thresholds and comfort levels. Statistical analysis using the Friedman test and Bonferroni correction assessed the impact of carrier and beat frequencies, and depth of modulation on activation thresholds and comfort. Main results. The results showed that the activation thresholds did not vary with the depth of modulation, challenging the core assumption underlying temporal interference stimulation. Despite that, comfort significantly increased with carrier frequencies as low as 500 Hz, with no further significant changes at higher frequencies. Computational modelling results showed an association between increased comfort and asynchronous nerve activation patterns, providing a possible explanation for the observed improvement in comfort. Significance. By challenging a core assumption of TI stimulation, this study shifts the focus from threshold modulation to optimising comfort in peripheral nerve stimulation. These findings establish a foundation for developing kilohertz-frequency stimulation protocols prioritising user comfort, particularly in applications such as functional electrical stimulation for rehabilitation or sensory feedback for prostheses.
- 1 April 2025
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 22 (2) , 026044
Open AccessThe comfort of temporal interference stimulation on the forearm: computational and psychophysical evaluation
Objective. Transcutaneous electrical stimulation aims to restore sensation and function in individuals with sensory or motor deficits. However, limited selectivity and unintended nerve recruitment often result in discomfort. Temporal interference (TI) stimulation has been proposed as a novel approach to non-invasive nerve stimulation, hypothesising that low-frequency modulation of kilohertz carriers reduces activation thresholds. Prior studies have produced conflicting results regarding comfort in kilohertz-frequency stimulation, and the practical applicability of TI remains unclear. This study addresses these gaps by systematically analysing the role of depth of modulation in activation thresholds and comfort, focusing on peripheral nerves and clinically relevant stimulation levels. Approach. This study uses a dual-method approach combining computational and psychophysical experiments targeting the median nerve. Computational modelling involved nine magnetic resonance imaging-informed finite element models to account for anatomical variability and biophysical neural activation predictions using NEURON., test Psychophysical experiments with 19 participants determined stimulation thresholds and comfort levels. Statistical analysis using the Friedman test and Bonferroni correction assessed the impact of carrier and beat frequencies, and depth of modulation on activation thresholds and comfort. Main results. The results showed that the activation thresholds did not vary with the depth of modulation, challenging the core assumption underlying temporal interference stimulation. Despite that, comfort significantly increased with carrier frequencies as low as 500 Hz, with no further significant changes at higher frequencies. Computational modelling results showed an association between increased comfort and asynchronous nerve activation patterns, providing a possible explanation for the observed improvement in comfort. Significance. By challenging a core assumption of TI stimulation, this study shifts the focus from threshold modulation to optimising comfort in peripheral nerve stimulation. These findings establish a foundation for developing kilohertz-frequency stimulation protocols prioritising user comfort, particularly in applications such as functional electrical stimulation for rehabilitation or sensory feedback for prostheses.