Nea Heilala
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Nea Heilala has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Janne Jänis
University of Eastern Finland P.O. Box 111
4 shared publications Jarkko J. Saarinen
Department of Chemistry and Sustainable Technology, University of Eastern Finland, P.O. Box 111, Joensuu FI-80101, Finland
4 shared publications- Ville H. Nissinen
Department of Chemistry and Sustainable Technology, University of Eastern Finland, Joensuu, Finland
4 shared publications Ilkka Rytöluoto
VTT Technical Research Centre of Finland Ltd., P.O. Box 1300, Tampere FI-33101, Finland
3 shared publications- Paavo Auvinen
Univ Eastern Finland, Dept Chem, POB 111, FI-80101 Joensuu, Finland
3 shared publications - Krista Grönlund
Department of Chemistry and Sustainable Technology, University of Eastern Finland, P. O. Box 111, FI-80101 Joensuu, Finland
2 shared publications
Latest Publications
- Open Access
- 3 April 2026
- Published by American Chemical Society (ACS) in ACS Sustainable Resource Management
- Vol. 3 (4) , 1192-1204
Decontaminating Plastic Recyclates via Solvothermal Extraction of Brominated Flame Retardants
Removing hazardous additives, such as brominated flame retardants (BFRs), from plastics is essential for mitigating the environmental burden of BFR-contaminated plastic recyclates. In this study, bromine-rich acrylonitrile–butadiene–styrene (ABS) and high-impact polystyrene (HIPS) samples from a recycling facility were extracted in an autoclave using mixtures of water, isopropanol (IPA), and sodium hydroxide (NaOH) as solvents. The total bromine content of the samples was quantified by X-ray fluorescence (XRF), while organic additives were analyzed using direct insertion probe mass spectrometry (DIP-MS). Initial characterization revealed the presence of multiple BFRs and other additives in both recyclates. Through process optimization, covering extraction time, temperature, and solvent composition, the solvothermal extraction methods proved effective in removing these additives. For the ABS sample, the H2O/IPA/NaOH extraction allowed efficient bromine removal (94%) at 125 °C, while for r-HIPS, the highest bromine removal (69%) was achieved through repeated extractions using IPA/NaOH at 100 °C. Intriguingly, extraction selectivity could be tuned by adjusting the extraction conditions and solvent composition. Overall, the findings highlighted that the extraction process should be optimized for each specific waste composition. The applied protocol, utilizing relatively mild conditions and environmentally friendly solvents, holds the potential for enhancing plastic recyclability and reducing the environmental impact of BFRs.
- 3 April 2026
- Published by American Chemical Society (ACS) in ACS Sustainable Resource Management
- Vol. 3 (4) , 1192-1204
Open AccessDecontaminating Plastic Recyclates via Solvothermal Extraction of Brominated Flame Retardants
Removing hazardous additives, such as brominated flame retardants (BFRs), from plastics is essential for mitigating the environmental burden of BFR-contaminated plastic recyclates. In this study, bromine-rich acrylonitrile–butadiene–styrene (ABS) and high-impact polystyrene (HIPS) samples from a recycling facility were extracted in an autoclave using mixtures of water, isopropanol (IPA), and sodium hydroxide (NaOH) as solvents. The total bromine content of the samples was quantified by X-ray fluorescence (XRF), while organic additives were analyzed using direct insertion probe mass spectrometry (DIP-MS). Initial characterization revealed the presence of multiple BFRs and other additives in both recyclates. Through process optimization, covering extraction time, temperature, and solvent composition, the solvothermal extraction methods proved effective in removing these additives. For the ABS sample, the H2O/IPA/NaOH extraction allowed efficient bromine removal (94%) at 125 °C, while for r-HIPS, the highest bromine removal (69%) was achieved through repeated extractions using IPA/NaOH at 100 °C. Intriguingly, extraction selectivity could be tuned by adjusting the extraction conditions and solvent composition. Overall, the findings highlighted that the extraction process should be optimized for each specific waste composition. The applied protocol, utilizing relatively mild conditions and environmentally friendly solvents, holds the potential for enhancing plastic recyclability and reducing the environmental impact of BFRs.
- Open Access
- 2 March 2026
- Published by American Chemical Society (ACS) in Macromolecules
- Vol. 59 (6) , 3753-3764
Chemical Fingerprinting of Synthetic Polymers via Direct Insertion Probe Mass Spectrometry
We report on the chemical fingerprinting of synthetic polymers using direct insertion probe mass spectrometry (DIP-MS), an analytical approach requiring only minimal sample preparation. A total of 38 different polymers were analyzed using temperature-programmed DIP-MS with atmospheric pressure chemical ionization (APCI) to establish a comprehensive spectral library. The studied polymers included homo- and copolymers from various classes, such as polyolefins, polyethers, polyesters, polyamides, styrenics, thermoplastic elastomers, and fluoropolymers. DIP-APCI-MS provided detailed structural information, enabling reliable identification of nearly all polymers based on their characteristic thermal decomposition patterns. Moreover, the utilization of temperature-programmed approach allowed monitoring of sample degradation as a function of temperature, further aiding polymer identification. Overall, temperature-programmed DIP-APCI-MS proved to be a robust and efficient method for the chemical fingerprinting of synthetic polymers, with potential applications in areas such as microplastic analysis and plastic recycling.
- 2 March 2026
- Published by American Chemical Society (ACS) in Macromolecules
- Vol. 59 (6) , 3753-3764
Open AccessChemical Fingerprinting of Synthetic Polymers via Direct Insertion Probe Mass Spectrometry
We report on the chemical fingerprinting of synthetic polymers using direct insertion probe mass spectrometry (DIP-MS), an analytical approach requiring only minimal sample preparation. A total of 38 different polymers were analyzed using temperature-programmed DIP-MS with atmospheric pressure chemical ionization (APCI) to establish a comprehensive spectral library. The studied polymers included homo- and copolymers from various classes, such as polyolefins, polyethers, polyesters, polyamides, styrenics, thermoplastic elastomers, and fluoropolymers. DIP-APCI-MS provided detailed structural information, enabling reliable identification of nearly all polymers based on their characteristic thermal decomposition patterns. Moreover, the utilization of temperature-programmed approach allowed monitoring of sample degradation as a function of temperature, further aiding polymer identification. Overall, temperature-programmed DIP-APCI-MS proved to be a robust and efficient method for the chemical fingerprinting of synthetic polymers, with potential applications in areas such as microplastic analysis and plastic recycling.
- Open Access
- 24 August 2025
- Published by Elsevier in The Journal of Supercritical Fluids
- Vol. 228
Extraction of brominated flame retardants from acrylonitrile butadiene styrene (ABS) using supercritical carbon dioxide
- 24 August 2025
- Published by Elsevier in The Journal of Supercritical Fluids
- Vol. 228
Open AccessExtraction of brominated flame retardants from acrylonitrile butadiene styrene (ABS) using supercritical carbon dioxide
- Open Access
- 11 April 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97 (15) , 8600-8608
Quantification of Brominated Flame Retardants in Synthetic Polymers via Direct Mass Spectrometric Analysis
Brominated flame retardants (BFRs) are persistent organic pollutants commonly encountered in plastics. Herein, we report on the quantification of BFRs directly from plastic samples via direct insertion probe mass spectrometry (DIP-MS). The study was conducted using model polymer samples comprising either acrylonitrile butadiene styrene copolymer (ABS) or high impact polystyrene (HIPS) and a BFR, namely decabromodiphenyl ether (decaBDE), hexabromocyclododecane (HBCD), or tetrabromobisphenol A (TBBPA). DIP-MS enabled direct quantification of decaBDE and TBBPA from both ABS and HIPS matrices. A linear correlation between BFR signal intensity and bromine (Br) content of the samples, as determined by X-ray fluorescence, was established over a Br concentration range of 0-7 wt %, or even higher. While DIP-MS showed potential for HBCD analysis as well, its effectiveness for quantitative HBCD determination remains partly uncertain due to the observed reactivity of HBCD during sample preparation. The detection limits for all studied BFRs were below 500 mg Br/kg. Additionally, the study shed light on matrix effects related to additive analysis by DIP-MS, revealing that the polymer and other additives can affect BFR volatilization and reactivity. Overall, DIP-MS demonstrated significant potential for the rapid quantification of BFRs from plastic samples with minimal sample preparation, which is imperative for promoting more efficient plastic recycling.
- 11 April 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97 (15) , 8600-8608
Open AccessQuantification of Brominated Flame Retardants in Synthetic Polymers via Direct Mass Spectrometric Analysis
Brominated flame retardants (BFRs) are persistent organic pollutants commonly encountered in plastics. Herein, we report on the quantification of BFRs directly from plastic samples via direct insertion probe mass spectrometry (DIP-MS). The study was conducted using model polymer samples comprising either acrylonitrile butadiene styrene copolymer (ABS) or high impact polystyrene (HIPS) and a BFR, namely decabromodiphenyl ether (decaBDE), hexabromocyclododecane (HBCD), or tetrabromobisphenol A (TBBPA). DIP-MS enabled direct quantification of decaBDE and TBBPA from both ABS and HIPS matrices. A linear correlation between BFR signal intensity and bromine (Br) content of the samples, as determined by X-ray fluorescence, was established over a Br concentration range of 0-7 wt %, or even higher. While DIP-MS showed potential for HBCD analysis as well, its effectiveness for quantitative HBCD determination remains partly uncertain due to the observed reactivity of HBCD during sample preparation. The detection limits for all studied BFRs were below 500 mg Br/kg. Additionally, the study shed light on matrix effects related to additive analysis by DIP-MS, revealing that the polymer and other additives can affect BFR volatilization and reactivity. Overall, DIP-MS demonstrated significant potential for the rapid quantification of BFRs from plastic samples with minimal sample preparation, which is imperative for promoting more efficient plastic recycling.