Elizabeth S. Brewer
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Elizabeth S. Brewer has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Milad Almasian
Department of Bioengineering The University of Texas at Dallas Richardson Texas USA
3 shared publications - Yichen Ding
The University of Texas at Dallas
3 shared publications - Alireza Saberigarakani
Department of Bioengineering The University of Texas at Dallas Richardson Texas USA
2 shared publications - Dan Tong
University of Texas Southwestern Medical Center
2 shared publications Sarah A. Ware
Department of Internal Medicine Division of Cardiology UT Southwestern Medical Center Dallas Texas USA
2 shared publicationsXinyuan Zhang
Department of Bioengineering The University of Texas at Dallas Richardson Texas USA
2 shared publications
Latest Publications
- Open Access
- 19 November 2026
- Published by Wiley in Advanced Science
Mapping Mesoscale Cardiac Architecture With Axially Swept Dithered Light‐Sheet Microscopy
Comprehensive characterization of cardiac microstructure and vascular networks is critical for assessing cardiovascular development, disease progression, and therapeutic interventions. While volumetric imaging combined with tissue clearing enables high‐resolution organ‐level analysis, the densely organized cardiac microenvironment, characterized by compacted and trabeculated myocardium, remains technically challenging to resolve in its entirety. To address these limitations, we exploit the temporal dynamics of illumination‐detection interplay to create a time‐averaged beam profile, thereby maximizing system throughput across multi‐scale specimens. Our dithered light‐sheet (DiLS) approach extends the confocal region by over 40% and improves the space‐bandwidth product while largely preserving optical sectioning capability. Building on this, the axially swept dithered light‐sheet (AS‐DiLS) employs a dual‐actuator strategy that combines rapid beam dithering and axial sweeping to further accelerate imaging speed while achieving micrometer‐scale resolution across centimeter‐scale scanning ranges, enabling detailed cardiovascular morphological and topological assessment from embryonic to adult stages. We anticipate that this scalable imaging scheme will advance in‐depth investigations of organ morphogenesis and disease pathogenesis across a broad spectrum of models.
- 19 November 2026
- Published by Wiley in Advanced Science
Open AccessMapping Mesoscale Cardiac Architecture With Axially Swept Dithered Light‐Sheet Microscopy
Comprehensive characterization of cardiac microstructure and vascular networks is critical for assessing cardiovascular development, disease progression, and therapeutic interventions. While volumetric imaging combined with tissue clearing enables high‐resolution organ‐level analysis, the densely organized cardiac microenvironment, characterized by compacted and trabeculated myocardium, remains technically challenging to resolve in its entirety. To address these limitations, we exploit the temporal dynamics of illumination‐detection interplay to create a time‐averaged beam profile, thereby maximizing system throughput across multi‐scale specimens. Our dithered light‐sheet (DiLS) approach extends the confocal region by over 40% and improves the space‐bandwidth product while largely preserving optical sectioning capability. Building on this, the axially swept dithered light‐sheet (AS‐DiLS) employs a dual‐actuator strategy that combines rapid beam dithering and axial sweeping to further accelerate imaging speed while achieving micrometer‐scale resolution across centimeter‐scale scanning ranges, enabling detailed cardiovascular morphological and topological assessment from embryonic to adult stages. We anticipate that this scalable imaging scheme will advance in‐depth investigations of organ morphogenesis and disease pathogenesis across a broad spectrum of models.
- Open Access
Whole-organ surface mapping using multiview projection reconstruction
While light-sheet microscopy is emerging as a robust method for volumetric imaging with improved axial resolution, its capability regarding two-dimensional, surface-level mapping is often hindered by limitations in data redundancy and reconstruction efficiency stemming from volumetric registration methods. We demonstrate that a multiview imaging approach in an axially-swept, dithered light-sheet microscope paired with computational image reconstruction of view projections is able to address these trade-offs to enable large-scale mapping of surface structural features, leveraging the advantages of multiview light-sheet in scalable field of view, working distance, and near isotropic resolution across the entire imaging depth. To aid in the acquisition and analysis of two-dimensional surface structures, we present a tailored surface mapping workflow and a Fiji plugin for computational reconstruction, promoting robust and comprehensive visualization of surface features of uncleared volumetric samples. Our strategy, termed projection reconstruction for imaging surface morphology (PRISM), integrates axially swept dithered light-sheet microscopy and post-processing software for multiview imaging. The imaging hardware enables near-isotropic resolution across its entire field of view, while the software implementation leverages rigid and affine transformations to align two-dimensional projections of multiview samples. It is designed to work with the BigStitcher pipeline, leveraging its robust algorithm to provide support for two-dimensional image alignment and stitching. We demonstrate the capability of PRISM in studies of lymphatic network mapping in the epicardial layer of intact mouse hearts, as well as surface profiles of FaDu spheroids labeled with antibody-nanodiamond conjugates. This method allows us to quantify cardiac lymphatic branch numbers, diameters, and lengths of a Prox1-tdTomato mouse cardiac model, as well as cluster number and diameters of epidermal growth factor receptor within a FaDu spheroid labeled with a nanodiamond-antibody conjugate, with a significant reduction of post-processing data size. PRISM leverages multiview image projections to promote studies of cardiac lymphatics in mouse models and surface receptor distributions within spheroid models, enabling efficient surface mapping of large, intact, and uncleared biological samples across a variety of scales.
Open AccessWhole-organ surface mapping using multiview projection reconstruction
While light-sheet microscopy is emerging as a robust method for volumetric imaging with improved axial resolution, its capability regarding two-dimensional, surface-level mapping is often hindered by limitations in data redundancy and reconstruction efficiency stemming from volumetric registration methods. We demonstrate that a multiview imaging approach in an axially-swept, dithered light-sheet microscope paired with computational image reconstruction of view projections is able to address these trade-offs to enable large-scale mapping of surface structural features, leveraging the advantages of multiview light-sheet in scalable field of view, working distance, and near isotropic resolution across the entire imaging depth. To aid in the acquisition and analysis of two-dimensional surface structures, we present a tailored surface mapping workflow and a Fiji plugin for computational reconstruction, promoting robust and comprehensive visualization of surface features of uncleared volumetric samples. Our strategy, termed projection reconstruction for imaging surface morphology (PRISM), integrates axially swept dithered light-sheet microscopy and post-processing software for multiview imaging. The imaging hardware enables near-isotropic resolution across its entire field of view, while the software implementation leverages rigid and affine transformations to align two-dimensional projections of multiview samples. It is designed to work with the BigStitcher pipeline, leveraging its robust algorithm to provide support for two-dimensional image alignment and stitching. We demonstrate the capability of PRISM in studies of lymphatic network mapping in the epicardial layer of intact mouse hearts, as well as surface profiles of FaDu spheroids labeled with antibody-nanodiamond conjugates. This method allows us to quantify cardiac lymphatic branch numbers, diameters, and lengths of a Prox1-tdTomato mouse cardiac model, as well as cluster number and diameters of epidermal growth factor receptor within a FaDu spheroid labeled with a nanodiamond-antibody conjugate, with a significant reduction of post-processing data size. PRISM leverages multiview image projections to promote studies of cardiac lymphatics in mouse models and surface receptor distributions within spheroid models, enabling efficient surface mapping of large, intact, and uncleared biological samples across a variety of scales.
- 1 April 2025
- Published by Optica Publishing Group in Optics Letters
- Vol. 50 (7) , 2457-2460
Resolution enhancement by subpixel sampling and computational reconstruction
Image resolution and field of view in far-field optical microscopy are often inversely proportional to one another due to digital sampling limitations imposed by the magnification of the system and the pixel size of the sensor. We present a method including a spatial shifting mechanism and a reconstruction algorithm that bypasses this trade-off by shifting the sample to be imaged by subpixel increments, before registering the images via phase correlation and combining the resulting registered images using the shift-and-add approach. Importantly, this method requires no specific optical components that are uncommon to commercially available or custom-built microscope systems. The findings of the presented study demonstrate an improvement to spatial resolution of ∼42% while maintaining the system’s field of view (FOV), leading to a more than twofold improvement to the system’s space–bandwidth product (SBP).
- 1 April 2025
- Published by Optica Publishing Group in Optics Letters
- Vol. 50 (7) , 2457-2460
Resolution enhancement by subpixel sampling and computational reconstruction
Image resolution and field of view in far-field optical microscopy are often inversely proportional to one another due to digital sampling limitations imposed by the magnification of the system and the pixel size of the sensor. We present a method including a spatial shifting mechanism and a reconstruction algorithm that bypasses this trade-off by shifting the sample to be imaged by subpixel increments, before registering the images via phase correlation and combining the resulting registered images using the shift-and-add approach. Importantly, this method requires no specific optical components that are uncommon to commercially available or custom-built microscope systems. The findings of the presented study demonstrate an improvement to spatial resolution of ∼42% while maintaining the system’s field of view (FOV), leading to a more than twofold improvement to the system’s space–bandwidth product (SBP).