KZKai-Peter Zimmermann

Kai-Peter Zimmermann

*This is an algorithmically generated author record based on publicly available information.

Kai-Peter Zimmermann has a total of 7 co-authors. Here are the top co-authors by number of shared publications:

  • Daniel Seidel

    Private Practice and Independent Researcher, 09117 Chemnitz, Germany

    1 shared publication
  • Günter Dhom

    Private Practice for Oral Surgery and Implant Dentistry, 67059 Ludwigshafen, Germany

    1 shared publication
  • Jörg Neugebauer

    Department for Oral and Craniomaxillofacial and Plastic Surgery, University Hospital Cologne, University of Cologne Faculty of Medicine, 50931 Cologne, Germany

    1 shared publication
  • Octavio Weinhold

    Academic Teaching and Research Institution of the Johann Wolfgang Goethe University Frankfurt am Main, Private Practice for Oral Surgery and Implant Dentistry, 67059 Ludwigshafen, Germany

    1 shared publication
  • Paul Weigl

    Department of Postgraduate Education, Center for Dentistry and Oral Medicine (Carolinum), University Hospital, Goethe University Frankfurt, 60596 Frankfurt, Germany

    1 shared publication
  • Peter Gehrke

    Department for Oral, Cranio-Maxillofacial and Facial Plastic Surgery, Goethe University, University Hospital Frankfurt, Frankfurt am Main, Germany

    1 shared publication

Latest Publications

  • Open Access

    A Comparative Evaluation of the Primary and Secondary Stability of Dental Implants with Progressive and Conventional Thread Designs: A Prospective Non-Interventional Study of 100 Implants in 62 Patients

    by Daniel Seidel, Jörg Neugebauer, Günter Dhom, Octavio Weinhold, Kai-Peter Zimmermann, Robert Sader, Paul Weigl, Peter Gehrke

    Objectives: We wished to compare the primary and secondary stability of dental implants with a progressive design (PL) versus a conventional thread design (SL) across various clinical settings. Methods: A total of 100 implants (50 PL and 50 SL) were placed in 62 patients. The stability of the implants was assessed using a resonance frequency analysis (RFA) at the time of placement (T1) and 20 weeks postoperatively before prosthetic loading (T2). Bone density was measured in Hounsfield units (HU) using cone-beam computed tomography (CBCT). The ISQ values were recorded for each group and anatomical region, including both inter- and intragroup comparisons over time. Results: Both implant designs showed a significant increase in stability during the healing period. At T1, the ISQ values were comparable between groups (SL: 71.3 ± 8.6; PL: 71.1 ± 8.7). At T2, the ISQ values increased significantly in both groups (SL and PL: p < 0.01), with no statistically significant difference in the degree of the gain in stability. The ISQ values were generally lower in the maxilla compared to those in the mandible. In the posterior mandible, the SL implants demonstrated a greater increase in stability compared to that with the PL implants. A strong positive correlation between the HU and ISQ values was observed for both groups (SL: r = 0.95; PL: r = 1.00), without reaching statistical significance. Conclusions: While the progressive thread design aims to enhance the primary stability, it did not outperform the conventional design in this study. Both implant types proved effective in achieving stable and predictable clinical outcomes.