Enrique Almar-Munoz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Enrique Almar-Munoz has a total of 78 co-authors. Here are the top co-authors by number of shared publications:
- Agnes Mayr
University Clinic of Radiology, Medical University of Innsbruck, Anichstraße 35, 6020 Innsbruck, Austria
5 shared publications - Christian Kremser
Department of Radiology, Medical University of Innsbruck, 6020 Innsbruck, Austria
4 shared publications Markus Haltmeier
Department of Mathematics, University of Innsbruck, Innsbruck, Austria
3 shared publications- Markus Haltmeier
Universität Innsbruck
3 shared publications Agnes Mayr
2 shared publicationsChristian Kremser
2 shared publications
Latest Publications
- 1 June 2026
- Published by Radiological Society of North America (RSNA) in Radiology: Cardiothoracic Imaging
- Vol. 8 (3) , e250235
Association of Deep Learning–based Myocardial Infarction Size Quantification in Cardiac MRI with Cardiac Biomarker Levels
A deep learning–based pipeline developed for infarct size quantification on cardiac MR images demonstrated stronger correlations with cardiac biomarkers than manual measurements did, supporting its clinical applicability.
- 1 June 2026
- Published by Radiological Society of North America (RSNA) in Radiology: Cardiothoracic Imaging
- Vol. 8 (3) , e250235
Association of Deep Learning–based Myocardial Infarction Size Quantification in Cardiac MRI with Cardiac Biomarker Levels
A deep learning–based pipeline developed for infarct size quantification on cardiac MR images demonstrated stronger correlations with cardiac biomarkers than manual measurements did, supporting its clinical applicability.
- 7 March 2026
- Published by Elsevier in Medical Image Analysis
- Vol. 111, 104015
MedSapiens: Taking a pose to rethink medical imaging landmark detection
- 7 March 2026
- Published by Elsevier in Medical Image Analysis
- Vol. 111, 104015
MedSapiens: Taking a pose to rethink medical imaging landmark detection
- 28 January 2026
- Published by Springer Nature
- p. 47-58
Combining Region-Based and Topological Losses in the nnU-Net Framework for Advanced Aorta Segmentation
- 28 January 2026
- Published by Springer Nature
- p. 47-58
Combining Region-Based and Topological Losses in the nnU-Net Framework for Advanced Aorta Segmentation
- Open Access
FUGC: Benchmarking Semi-Supervised Learning Methods for Cervical Segmentation
Accurate segmentation of cervical structures in transvaginal ultrasound (TVS) is critical for assessing the risk of spontaneous preterm birth (PTB), yet the scarcity of labeled data limits the performance of supervised learning approaches. This paper introduces the Fetal Ultrasound Grand Challenge (FUGC), the first benchmark for semi-supervised learning in cervical segmentation, hosted at ISBI 2025. FUGC provides a dataset of 890 TVS images, including 500 training images, 90 validation images, and 300 test images. Methods were evaluated using the Dice Similarity Coefficient (DSC), Hausdorff Distance (HD), and runtime (RT), with a weighted combination of 0.4/0.4/0.2. The challenge attracted 10 teams with 82 participants submitting innovative solutions. The best-performing methods for each individual metric achieved 90.26\% mDSC, 38.88 mHD, and 32.85 ms RT, respectively. FUGC establishes a standardized benchmark for cervical segmentation, demonstrates the efficacy of semi-supervised methods with limited labeled data, and provides a foundation for AI-assisted clinical PTB risk assessment.
Open AccessFUGC: Benchmarking Semi-Supervised Learning Methods for Cervical Segmentation
Accurate segmentation of cervical structures in transvaginal ultrasound (TVS) is critical for assessing the risk of spontaneous preterm birth (PTB), yet the scarcity of labeled data limits the performance of supervised learning approaches. This paper introduces the Fetal Ultrasound Grand Challenge (FUGC), the first benchmark for semi-supervised learning in cervical segmentation, hosted at ISBI 2025. FUGC provides a dataset of 890 TVS images, including 500 training images, 90 validation images, and 300 test images. Methods were evaluated using the Dice Similarity Coefficient (DSC), Hausdorff Distance (HD), and runtime (RT), with a weighted combination of 0.4/0.4/0.2. The challenge attracted 10 teams with 82 participants submitting innovative solutions. The best-performing methods for each individual metric achieved 90.26\% mDSC, 38.88 mHD, and 32.85 ms RT, respectively. FUGC establishes a standardized benchmark for cervical segmentation, demonstrates the efficacy of semi-supervised methods with limited labeled data, and provides a foundation for AI-assisted clinical PTB risk assessment.
- Open Access
- 19 December 2025
- Published by Elsevier in Intelligence-Based Medicine
- Vol. 13
Cardiac Magnetic Resonance-to-Computed Tomography Angiography image conversion using diffusion models for Transcatheter Aortic Valve Implantation planning
- 19 December 2025
- Published by Elsevier in Intelligence-Based Medicine
- Vol. 13
Open AccessCardiac Magnetic Resonance-to-Computed Tomography Angiography image conversion using diffusion models for Transcatheter Aortic Valve Implantation planning
- Open Access
- 20 November 2025
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 14 (22) , 8255
Are Image-Based Deep Learning Algorithms of Kidney Volume in Polycystic Kidney Disease Ready for Clinical Deployment? A Systematic Review and Meta-Analysis
Objectives: In patients with autosomal dominant polycystic kidney disease (ADPKD), total kidney volume (TKV) is the gold standard biomarker for assessing the risk of progression and the need for drug therapy. However, it is a time-consuming process. In this systematic review and meta-analysis, we evaluate the current state of deep learning (DL) algorithms for automatic kidney volume segmentation. Methods: All original research, including the search terms ADPKD, diagnostic imaging, DL, and TKV, was identified in PubMed, Embase, and Ovid MEDLINE databases from January 2000 to 13 October 2024. Articles with insufficient information to assess methodological quality were excluded. Quality was assessed using the “Quality Assessment of Diagnostic Accuracy Studies, Version 2” (QUADAS-2) and Checklist for Artificial Intelligence in Medical Imaging (CLAIM) tools. We focused on the Dice Similarity Coefficient (DSC), bias differences, and time efficiency as outcomes. Results: Nineteen studies were included, with an overall low risk of bias; however, the mean adherence to the CLAIM checklist was 64%. The pooled DSC under the random-effects model was (95% CI: ) with relatively low bias for TKV in 5622 ADPKD patients (mean age, 46.1 years; 45% male) and 9180 scans (79% MRI). The average segmentation time was decreased by 75% compared to the ground truth. Performance differences were evident among imaging modalities, MRI sequences, and 3D vs. 2D models, but not among imaging planes. The between-study heterogeneity was low (), and no statistically significant evidence of small-study effects or publication bias was detected. Conclusions: DL models for TKV in ADPKD patients demonstrated high precision compared to manual segmentation in a large, pooled sample with heterogeneous study designs and methods. While clinical implementation is not yet feasible, the current work demonstrates the technical and diagnostic efficacy of image-based DL segmentation models.- 20 November 2025
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 14 (22) , 8255
Open AccessAre Image-Based Deep Learning Algorithms of Kidney Volume in Polycystic Kidney Disease Ready for Clinical Deployment? A Systematic Review and Meta-Analysis
Objectives: In patients with autosomal dominant polycystic kidney disease (ADPKD), total kidney volume (TKV) is the gold standard biomarker for assessing the risk of progression and the need for drug therapy. However, it is a time-consuming process. In this systematic review and meta-analysis, we evaluate the current state of deep learning (DL) algorithms for automatic kidney volume segmentation. Methods: All original research, including the search terms ADPKD, diagnostic imaging, DL, and TKV, was identified in PubMed, Embase, and Ovid MEDLINE databases from January 2000 to 13 October 2024. Articles with insufficient information to assess methodological quality were excluded. Quality was assessed using the “Quality Assessment of Diagnostic Accuracy Studies, Version 2” (QUADAS-2) and Checklist for Artificial Intelligence in Medical Imaging (CLAIM) tools. We focused on the Dice Similarity Coefficient (DSC), bias differences, and time efficiency as outcomes. Results: Nineteen studies were included, with an overall low risk of bias; however, the mean adherence to the CLAIM checklist was 64%. The pooled DSC under the random-effects model was (95% CI: ) with relatively low bias for TKV in 5622 ADPKD patients (mean age, 46.1 years; 45% male) and 9180 scans (79% MRI). The average segmentation time was decreased by 75% compared to the ground truth. Performance differences were evident among imaging modalities, MRI sequences, and 3D vs. 2D models, but not among imaging planes. The between-study heterogeneity was low (), and no statistically significant evidence of small-study effects or publication bias was detected. Conclusions: DL models for TKV in ADPKD patients demonstrated high precision compared to manual segmentation in a large, pooled sample with heterogeneous study designs and methods. While clinical implementation is not yet feasible, the current work demonstrates the technical and diagnostic efficacy of image-based DL segmentation models. - 14 November 2025
- Published by Springer Nature
- p. 163-172
Cine-CLIP: Reducing Cine-MRI Dimensionality with Temporal Variability for Left Ventricular Ejection Fraction Estimation
- 14 November 2025
- Published by Springer Nature
- p. 163-172
Cine-CLIP: Reducing Cine-MRI Dimensionality with Temporal Variability for Left Ventricular Ejection Fraction Estimation
- Open Access
- 17 September 2025
- Published by MDPI AG in Journal of Imaging
- Vol. 11 (9) , 318
Uncertainty-Guided Active Learning for Access Route Segmentation and Planning in Transcatheter Aortic Valve Implantation
Transcatheter aortic valve implantation (TAVI) is a minimally invasive procedure for treating severe aortic stenosis, where optimal vascular access route selection is critical to reduce complications. It requires careful selection of the iliac artery with the most favourable anatomy, specifically, one with the largest diameters and no segments narrower than 5 . This process is time-consuming when carried out manually. We present an active learning-based segmentation framework for contrast-enhanced Cardiac Magnetic Resonance (CMR) data, guided by probabilistic uncertainty and pseudo-labelling, enabling efficient segmentation with minimal manual annotation. The segmentations are then fed into an automated pipeline for diameter quantification, achieving a Dice score of and a mean absolute percentage error (MAPE) of 4.92%. An ablation study using pre- and post-contrast CMR showed superior performance with post-contrast data only. Overall, the pipeline provides accurate segmentation and detailed diameter profiles of the aorto-iliac route, helping the assessment of the access route.- 17 September 2025
- Published by MDPI AG in Journal of Imaging
- Vol. 11 (9) , 318
Open AccessUncertainty-Guided Active Learning for Access Route Segmentation and Planning in Transcatheter Aortic Valve Implantation
Transcatheter aortic valve implantation (TAVI) is a minimally invasive procedure for treating severe aortic stenosis, where optimal vascular access route selection is critical to reduce complications. It requires careful selection of the iliac artery with the most favourable anatomy, specifically, one with the largest diameters and no segments narrower than 5 . This process is time-consuming when carried out manually. We present an active learning-based segmentation framework for contrast-enhanced Cardiac Magnetic Resonance (CMR) data, guided by probabilistic uncertainty and pseudo-labelling, enabling efficient segmentation with minimal manual annotation. The segmentations are then fed into an automated pipeline for diameter quantification, achieving a Dice score of and a mean absolute percentage error (MAPE) of 4.92%. An ablation study using pre- and post-contrast CMR showed superior performance with post-contrast data only. Overall, the pipeline provides accurate segmentation and detailed diameter profiles of the aorto-iliac route, helping the assessment of the access route. - 29 April 2025
- Published by Springer Nature
- p. 236-244
Multi-loss 3D Segmentation for Enhanced Bi-atrial Segmentation
- 29 April 2025
- Published by Springer Nature
- p. 236-244
Multi-loss 3D Segmentation for Enhanced Bi-atrial Segmentation