Yuntong Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yuntong Liu has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Chaofeng Ye
ShanghaiTech University
2 shared publications - Yu Tao
School of Information Science and Technology, ShanghaiTech University, Shanghai 201210, China
2 shared publications - Feng Chen
Shanghai Pudong International Airport Cargo Terminal Company Ltd., Shanghai, China
1 shared publication - Xiaoyue Meng
Shanghai Pudong International Airport Cargo Terminal Company Ltd., Shanghai, China
1 shared publication - Yang Wang
Shanghai Finesense Technology Company Ltd., Shanghai, China
1 shared publication
Latest Publications
- 4 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-10
Magnetic Anomaly Evaluation for Air Cargo Employing Array TMR Sensors and Deep Learning Algorithm
The swift advancement of e-commerce has led to an increased transit of magnetic items via air freight, which may jeopardize airplane safety. It is essential to detect and assess the magnetic anomalies for maintaining the flight safety. However, the industry still lacks online detection equipment for magnetic anomalies measurement. This paper presents an automated magnetic anomaly detection system that employs array tunnel magnetoresistance (TMR) sensors and a deep learning calculation algorithm. The system has four sensor arrays that are located on the four sides of a cargo conveyor belt to continuously monitor the magnetic field. The magnetic abnormalities are detected and quantified as the cargo passes through the sensor arrays. A deep learning algorithm is developed to ascertain the position and magnetic moment of magnetic sources, enabling a quantitative evaluation of the risk associated with magnetic abnormalities. A prototype system including 64 sensor modules has been developed and tested on an airport cargo conveyor belt to evaluate the practicality of the technology. Experimental validation on airport cargo belts shows that, for single‑source cases, the system attains a position RMSE of 3.22 cm and a dipole‑angle RMSE of 1.07°. In double‑source scenarios the corresponding errors are 13.18 cm and 25.07°, confirming reliable performance across both simple and complex magnetic configurations. This automated technology significantly improves the efficiency and reliability of magnetic anomaly detection in air transportation operations compared to the traditional method of using a handheld magnetometer.
- 4 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-10
Magnetic Anomaly Evaluation for Air Cargo Employing Array TMR Sensors and Deep Learning Algorithm
The swift advancement of e-commerce has led to an increased transit of magnetic items via air freight, which may jeopardize airplane safety. It is essential to detect and assess the magnetic anomalies for maintaining the flight safety. However, the industry still lacks online detection equipment for magnetic anomalies measurement. This paper presents an automated magnetic anomaly detection system that employs array tunnel magnetoresistance (TMR) sensors and a deep learning calculation algorithm. The system has four sensor arrays that are located on the four sides of a cargo conveyor belt to continuously monitor the magnetic field. The magnetic abnormalities are detected and quantified as the cargo passes through the sensor arrays. A deep learning algorithm is developed to ascertain the position and magnetic moment of magnetic sources, enabling a quantitative evaluation of the risk associated with magnetic abnormalities. A prototype system including 64 sensor modules has been developed and tested on an airport cargo conveyor belt to evaluate the practicality of the technology. Experimental validation on airport cargo belts shows that, for single‑source cases, the system attains a position RMSE of 3.22 cm and a dipole‑angle RMSE of 1.07°. In double‑source scenarios the corresponding errors are 13.18 cm and 25.07°, confirming reliable performance across both simple and complex magnetic configurations. This automated technology significantly improves the efficiency and reliability of magnetic anomaly detection in air transportation operations compared to the traditional method of using a handheld magnetometer.
- 19 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (7) , 10860-10867
Measurement of Transformer DC Bias Current Based on Integrated Array Magnetoresistance Sensors and Signal Fusion Algorithm
Accurately measuring transformer DC bias current is crucial due to its significant impact on the operational stability of the power system. It is difficult for existing technologies to balance the requirements of high sensitivity, reliability and convenient installation. This paper presents a non-contact Direct Current (DC) bias current measurement probe using tunnel magnetoresistance (TMR) sensor arrays. The probe contains 16 sensors, which are divided into four arrays. The sensors are bare die chips diced from an 8-inch wafer and then wire bonded on a printed circuit board. The distance between two adjacent sensors in an array is only 0.5 mm, resulting in approximately uniform magnetic field gradient for the sensors simplifying the calculation of the output. The sensors are connected as a push-pull Wheatstone bridge to convert the change of resistances to a voltage signal and to enhance the sensitivity. The distribution of the magnetic field is calculated numerically and the Shannon entropy of the signals are estimated. Then the output signals are fused based on weights calculated according to the magnetic field distribution and the Shannon entropy. This method allows for a balanced integration of both the linear characteristics of the signal and its intrinsic properties. Experimental results demonstrate that the system achieves a relative linearity error less than 0.95% for measuring DC currents in the range from -3000mA to 3000mA. This method is an alternative approach that can be utilized in the power system to monitor the transformer DC bias current.
- 19 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (7) , 10860-10867
Measurement of Transformer DC Bias Current Based on Integrated Array Magnetoresistance Sensors and Signal Fusion Algorithm
Accurately measuring transformer DC bias current is crucial due to its significant impact on the operational stability of the power system. It is difficult for existing technologies to balance the requirements of high sensitivity, reliability and convenient installation. This paper presents a non-contact Direct Current (DC) bias current measurement probe using tunnel magnetoresistance (TMR) sensor arrays. The probe contains 16 sensors, which are divided into four arrays. The sensors are bare die chips diced from an 8-inch wafer and then wire bonded on a printed circuit board. The distance between two adjacent sensors in an array is only 0.5 mm, resulting in approximately uniform magnetic field gradient for the sensors simplifying the calculation of the output. The sensors are connected as a push-pull Wheatstone bridge to convert the change of resistances to a voltage signal and to enhance the sensitivity. The distribution of the magnetic field is calculated numerically and the Shannon entropy of the signals are estimated. Then the output signals are fused based on weights calculated according to the magnetic field distribution and the Shannon entropy. This method allows for a balanced integration of both the linear characteristics of the signal and its intrinsic properties. Experimental results demonstrate that the system achieves a relative linearity error less than 0.95% for measuring DC currents in the range from -3000mA to 3000mA. This method is an alternative approach that can be utilized in the power system to monitor the transformer DC bias current.