Xiaopeng Luo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Xiaopeng Luo has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Guigang Yin
Kaidi Seiko Technology Company Ltd. Chengdu, China
1 shared publication - Jiangping Zhu
Sichuan University
1 shared publication - Pei Zhou
Sichuan University
1 shared publication - Zhoumiao He
College of Computer Science, Sichuan University, Chengdu, China
1 shared publication
Latest Publications
- 28 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-10
Bi-Telecentric Camera Calibration via Orthogonal Binary Phase Target for Shallow DoF and High-Accuracy Fringe Projection 3-D Microscopy
Current camera calibration methods typically require obtaining clear target images under various poses for accurate features detection. However, in many microscope 3D measurement practices, cameras imaging the tested precision parts usually have a narrow field of view (FoV) and shallow depth of field (DoF), making them difficult to capture clear target images. Due to little distortion and constant magnification,bitelecentric camera is extremely suitable for precision microscope 3D measurement. However, small FoV and DoF lead to its difficulty of accurate calibration especially under the defocused state. In this work, we design a novel orthogonal phase target that the pattern is generated via joint optimization of error diffusion kernel and quantization threshold error diffusion binary encoding algorithm, and then is transferred to glass substrate by laser direct writing. Simultaneously, a novel calibration approach is also presented that firstly employs Fourier transform (FT) to extract the horizontal and vertical phases information, then accurately locates phase feature points with a linear constraint strategy. Our solution offers remarkable adaptability and feasibility for calibrating bi-telecentric camera with shallow DoF of ±0.9mm, and achieves a re-projection error better than 0.08pixels and 3D measurement accuracy better 0.002mm within measurement volume of X 10.5mm × Y7.9mm × Z3.6mm, even when conventional calibration solutions fail. Such enhancements are instrumental in advancing the development of microscopy fringe projection 3D measurement.
- 28 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-10
Bi-Telecentric Camera Calibration via Orthogonal Binary Phase Target for Shallow DoF and High-Accuracy Fringe Projection 3-D Microscopy
Current camera calibration methods typically require obtaining clear target images under various poses for accurate features detection. However, in many microscope 3D measurement practices, cameras imaging the tested precision parts usually have a narrow field of view (FoV) and shallow depth of field (DoF), making them difficult to capture clear target images. Due to little distortion and constant magnification,bitelecentric camera is extremely suitable for precision microscope 3D measurement. However, small FoV and DoF lead to its difficulty of accurate calibration especially under the defocused state. In this work, we design a novel orthogonal phase target that the pattern is generated via joint optimization of error diffusion kernel and quantization threshold error diffusion binary encoding algorithm, and then is transferred to glass substrate by laser direct writing. Simultaneously, a novel calibration approach is also presented that firstly employs Fourier transform (FT) to extract the horizontal and vertical phases information, then accurately locates phase feature points with a linear constraint strategy. Our solution offers remarkable adaptability and feasibility for calibrating bi-telecentric camera with shallow DoF of ±0.9mm, and achieves a re-projection error better than 0.08pixels and 3D measurement accuracy better 0.002mm within measurement volume of X 10.5mm × Y7.9mm × Z3.6mm, even when conventional calibration solutions fail. Such enhancements are instrumental in advancing the development of microscopy fringe projection 3D measurement.