Aluizio D’AFfonsêca Netto
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Aluizio D’AFfonsêca Netto has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Antonio Mauricio Ferreira Leite Miranda de Sá
Universidade Federal do Rio de Janeiro
1 shared publication Carlos J. Tierra-Criollo
1 shared publication- Carlos Julio Tierra-Criollo
Biomedical Engineering Program-PEB, Federal University of Rio de Janeiro, Rio de Janeiro 21941-914, RJ, Brazil
1 shared publication - Danilo Andrés Molina-Vidal
Alberto Luiz Coimbra Institute for Graduate Studies and Research in Engineering (Coppe), Federal University of Rio de Janeiro
1 shared publication - David Martin Simpson
Department of Neurology, Icahn School of Medicine at Mount Sinai, New York, NY 10029, USA
1 shared publication - Leimer Guambaña-Calle
Biomedical Engineering Research Group—GIIB, Universidad Politécnica Salesiana, Cuenca 010102, Ecuador
1 shared publication
Latest Publications
- Open Access
- 6 February 2026
- Published by Elsevier in Measurement
- Vol. 268
A normalized spectral test for assessing non-flat spectrum near a given frequency
- 6 February 2026
- Published by Elsevier in Measurement
- Vol. 268
Open AccessA normalized spectral test for assessing non-flat spectrum near a given frequency
- Open Access
Prototype of a Multimodal and Multichannel Electro-Physiological and General-Purpose Signal Capture System: Evaluation in Sleep-Research-like Scenario
The simultaneous analysis of electrophysiological signals from various physiological systems, such as the brain, skeletal muscles, and cardiac muscles, has become increasingly necessary in both clinical and research settings. However, acquiring multiple modalities of electrophysiological data often necessitates the use of diverse, specialized technological tools, which can complicate the establishment of a comprehensive multimodal experimental setup. This paper introduces a prototype system, named the Multimodal–Multichannel Acquisition Module—MADQ, designed for the simultaneous acquisition of multimodal and multichannel electrophysiological and general-purpose signals. The MADQ comprises three distinct capturing blocks, each equipped with separate reference circuits, supporting a total of up to 40 electrophysiological input channels, alongside 4 channels of analog input and 4 channels of digital input signal. The system is capable of sampling frequencies up to 16 kHz. Key features of the MADQ include individually configurable bipolar recording, lead-off detection capability, and real-time online filtering. The system’s functional performance was characterized through metrics such as Input-Referred Noise (IRN), Noise-Free Bits (NFB), and Effective Number of Bits (ENOB) across varying gain and sampling frequencies. Preliminary experiments, conducted in a setup emulating a sleep study with auditory evoked potential detection, demonstrate the system’s potential for integration into multimodal experimental scenarios.
Open AccessPrototype of a Multimodal and Multichannel Electro-Physiological and General-Purpose Signal Capture System: Evaluation in Sleep-Research-like Scenario
The simultaneous analysis of electrophysiological signals from various physiological systems, such as the brain, skeletal muscles, and cardiac muscles, has become increasingly necessary in both clinical and research settings. However, acquiring multiple modalities of electrophysiological data often necessitates the use of diverse, specialized technological tools, which can complicate the establishment of a comprehensive multimodal experimental setup. This paper introduces a prototype system, named the Multimodal–Multichannel Acquisition Module—MADQ, designed for the simultaneous acquisition of multimodal and multichannel electrophysiological and general-purpose signals. The MADQ comprises three distinct capturing blocks, each equipped with separate reference circuits, supporting a total of up to 40 electrophysiological input channels, alongside 4 channels of analog input and 4 channels of digital input signal. The system is capable of sampling frequencies up to 16 kHz. Key features of the MADQ include individually configurable bipolar recording, lead-off detection capability, and real-time online filtering. The system’s functional performance was characterized through metrics such as Input-Referred Noise (IRN), Noise-Free Bits (NFB), and Effective Number of Bits (ENOB) across varying gain and sampling frequencies. Preliminary experiments, conducted in a setup emulating a sleep study with auditory evoked potential detection, demonstrate the system’s potential for integration into multimodal experimental scenarios.