    A high-resolution wireless sensing platform for the characterization of urodynamic events in murine models

    by Ramon Eduardo Cortina, Rodolfo Delgado Lezama, Fernando Pérez-Escamirosa, Luis Padilla, Daniel Lorias Espinoza, Arturo Minor-Martínez

    Cystometry in murine models is fundamental for understanding lower urinary tract dysfunctions. However, the high cost of commercial equipment and the mechanical limitations of wired systems, which can introduce electronic noise and restrict mobility, often hinder implementation and can compromise animal welfare. This work presents CISTREC, a low-cost, high-signal-integrity wireless pressure monitoring platform designed for preclinical research. The system integrates a digital sensor with on-chip signal conditioning and a 24-bit digital output, enabling direct digitization at the sensor and minimizing susceptibility to electromagnetic interference. Data transmission was performed via Bluetooth Low Energy 5.0 (BLE), providing galvanic isolation and portability. Validation included in vitro characterization from 0 to 160 cmH 2 O, and in vivo evaluation in an overactive bladder (OAB) model induced by acetic acid in Wistar rats. In vitro tests demonstrated a coefficient of determination of 0.999946, a root-mean-square error of 0.3454 cmH 2 O, an effective experimental resolution of 0.0742 cmH 2 O, and a full-scale signal-to-noise ratio (SNR FS ) of 76.23 dB. In the in vivo experiment, the high resolution enabled accurate capture of biomarkers, including high-frequency oscillations (HFOs) and non-voiding contractions (NVCs). Significant changes were observed in the pathological model, including a reduction in the inter-contraction interval and a decrease in bladder compliance. The CISTREC system achieves metrological performance in line with reported specifications of high-end commercial systems, at a low cost. Its wireless architecture and high sensitivity facilitate access to advanced urodynamics, promoting the principle of refinement in animal experimentation without compromising rigorous scientific standards.

  • Open Access

    UROREC: A cystometry and electromyography recording system for analyzing urinary incontinence parameters in rat models

    by Ramon Eduardo Cortina, Luis Padilla, Pilar Hazel Carranza-Castro, Fernando Pérez Escamirosa, Daniel Lorias Espinoza, Arturo Minor Martínez

    Preclinical research on the lower urinary tract relies heavily on murine models, which necessitates specialized equipment for acquiring concurrent electromyography and cystometry. However, commercial systems are often expensive and bulky, requiring dedicated workstations. These limitations hinder the reproducibility of complex urodynamic studies and restrict experimental accessibility. To address these limitations, we present the UROREC system, which is an accessible, compact, and reliable data acquisition platform designed to simultaneously record electromyography of the external urethral sphincter and intravesical pressure. We established the system’s robustness through benchtop electrical characterization and validated it via in vivo proof-of-concept pilot experiments in urethane-anesthetized female Wistar rats. Electrical testing confirmed a common-mode rejection ratio of 98.4 dB, an input-referred noise of 1.53 µV RMS, and linearity of R 2 = 0.9999. Meanwhile, the pressure sensor exhibited a maximum hysteresis of 0.29% at full scale. In vivo, the device reliably digitized electromyography signals at 20 ksps and pressure signals at 100 sps in both a healthy physiological state and an acetic acid–induced overactive bladder model. UROREC precisely quantified 18 cystometric and electromyographic parameters consistent with the existing literature. The robustness of these in vivo recordings was confirmed by quantifying the signal-to-noise ratio, demonstrating high operational reliability and data integrity across all experimental sessions. Furthermore, the system accurately captured high sensitivity to specific pathophysiological shifts induced by acid instillation, with a significant reduction in both the inter-contraction interval ( p < 0.001) and tonic activity duration ( p < 0.001). These results validate UROREC as a robust, cost-effective alternative that makes high-fidelity urodynamic monitoring more accessible and promotes methodological reproducibility in lower urinary tract research.

  • Bioinstrumentation Amplifier with Band-Pass Differential Filter Using Impedance Converter for Electrocardiography Signals

    by Abraham Hernández-Jiménez, Jesús F. Córdova-Manzo, Gibran Segovia-Cristiani, Ramon E. Cortina, Arturo Vera-Hernández, Lorenzo Lejía-Salas, Giselle M. Galván-Tejada


  • Open Access

    Low-cost larvae tracking using a magnetic sensor array system

    by Aaron Andrés Santana Hernandez, Luz Ávila-Caballero, Ramon Eduardo Cortina, Salvador Montoya Alvarez, Fernando Pérez Escamirosa, Arturo Minor Martínez

    Soil-dwelling pests, such as Phyllophaga larvae, pose significant challenges to agriculture as they feed on crop roots, causing substantial losses. Their hidden behavior within the soil further complicates monitoring and control efforts. Traditional methods, such as manual excavation and acoustic detection, are often invasive, labor-intensive, or limited in precision. To address these challenges, this study aimed to establish a reliable methodology to study larval trajectories and responses within the soil environment without disturbing its natural behavior. This study describes the development of an innovative system for precise tracking of these larvae, combining magnetic markers with an array of magnetoresistive sensors. Larvae were tagged with neodymium magnets and tracked using an array of 64 anisotropic magnetoresistive sensors while being attracted by food sources and repelled by electrical stimuli. The movement of larvae marked with magnetic tags and attracted by Zea mays and Solanum tuberosum roots was successfully monitored. The system was validated using a 3D printer framework as a reference, achieving high accuracy with minimal uncertainty. Adjustments were made to the z-axis to account for variations in the distance between the magnet and the sensor array. Experiments demonstrated the ability to guide larval behavior through controlled electrical stimuli, confirming the system's utility for monitoring and behavioral studies. This approach offers significant improvements over traditional methods by preserving soil integrity, enhancing precision, and enabling real-time tracking. The findings provide a valuable tool for understanding subterranean pest dynamics and support the development of sustainable pest management strategies in agriculture.