Jicong Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jicong Zhang has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
Hua Wang
School of Biological Science and Medical Engineering, Beihang University, Beijing, China
1 shared publicationJingfei Hu
School of Biological Science and Medical Engineering, Beihang University, Beijing, China
1 shared publicationMingkun Bao
School of Biological Science and Medical Engineering, Beihang University, Beijing, China
1 shared publicationShengbo Gao
School of Biological Science and Medical Engineering, Beihang University, Beijing, China
1 shared publicationTao Liu
School of Biological Science and Medical Engineering, Beihang University, Beijing, China
1 shared publicationYaxing Wang
Beijing TongRen Eye Center, Beijing TongRen Hospital, Capital Medical University, Beijing, China
1 shared publication
Latest Publications
- Open Access
- 17 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 7, 174167-174177
S-UNet: A Bridge-Style U-Net Framework With a Saliency Mechanism for Retinal Vessel Segmentation
Deep learning methods have been successfully applied in medical image classification, segmentation and detection tasks. The U-Net architecture has been widely applied for these tasks. In this paper, we propose a U-Net variant for improved vessel segmentation in retinal fundus images. Firstly, we design a minimal U-Net (Mi-UNet) architecture, which drastically reduces the parameter count to 0.07M compared to 31.03M for the conventional U-Net. Moreover, based on Mi-UNet, we propose Salient U-Net (S-UNet), a bridge-style U-Net architecture with a saliency mechanism and with only 0.21M parameters. SUNet uses a cascading technique that employs the foreground features of one net block as the foreground attention information of the next net block. This cascading leads to enhanced input images, inheritance of the learning experience of previous net blocks, and hence effective solution of the data imbalance problem. S-UNet was tested on two benchmark datasets, DRIVE and CHASE_DB1, with image sizes of 584×565 and 960×999, respectively. S-UNet was tested on the TONGREN clinical dataset with image sizes of 1880×2816. The experimental results show superior performance in comparison to other state-of-theart methods. Especially, for whole-image input from the DRIVE dataset, S-UNet achieved a Matthews correlation coefficient (MCC), an area under curve (AUC), and an F1 score of 0.8055, 0.9821, and 0.8303, respectively. The corresponding scores for the CHASE_DB1 dataset were 0.8065, 0.9867, and 0.8242, respectively. Moreover, our model shows an excellent performance on the TONGREN clinical dataset. In addition, S-UNet segments images of low, medium, and high resolutions in just 33ms, 91ms and 0.49s, respectively. This shows the real-time applicability of the proposed model.
- 17 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 7, 174167-174177
Open AccessS-UNet: A Bridge-Style U-Net Framework With a Saliency Mechanism for Retinal Vessel Segmentation
Deep learning methods have been successfully applied in medical image classification, segmentation and detection tasks. The U-Net architecture has been widely applied for these tasks. In this paper, we propose a U-Net variant for improved vessel segmentation in retinal fundus images. Firstly, we design a minimal U-Net (Mi-UNet) architecture, which drastically reduces the parameter count to 0.07M compared to 31.03M for the conventional U-Net. Moreover, based on Mi-UNet, we propose Salient U-Net (S-UNet), a bridge-style U-Net architecture with a saliency mechanism and with only 0.21M parameters. SUNet uses a cascading technique that employs the foreground features of one net block as the foreground attention information of the next net block. This cascading leads to enhanced input images, inheritance of the learning experience of previous net blocks, and hence effective solution of the data imbalance problem. S-UNet was tested on two benchmark datasets, DRIVE and CHASE_DB1, with image sizes of 584×565 and 960×999, respectively. S-UNet was tested on the TONGREN clinical dataset with image sizes of 1880×2816. The experimental results show superior performance in comparison to other state-of-theart methods. Especially, for whole-image input from the DRIVE dataset, S-UNet achieved a Matthews correlation coefficient (MCC), an area under curve (AUC), and an F1 score of 0.8055, 0.9821, and 0.8303, respectively. The corresponding scores for the CHASE_DB1 dataset were 0.8065, 0.9867, and 0.8242, respectively. Moreover, our model shows an excellent performance on the TONGREN clinical dataset. In addition, S-UNet segments images of low, medium, and high resolutions in just 33ms, 91ms and 0.49s, respectively. This shows the real-time applicability of the proposed model.