P. Polasek
Research Subjects
P. Polasek has a total of 2 co-authors. Here are the top co-authors by number of shared publications:
C. J. Wantenaar
1 shared publicationCj Wantenaar
P Polasek & Associates, PO Box 3136, Kyalami 1684, South Africa
1 shared publication
Latest Publications
- Open Access
- 22 February 2024
- Published by Global Journals in Global Journal of Researches in Engineering
- Vol. 24 (E1) , 35-67
High Rate Water Clarification Technology
At present the formation of flocculent suspension and its gravity separation are lengthy processes varying between 3 and 4.5 hours. Consequently this results in high capital costs. Therefore, reconsideration of the kinetics of formation of the flocculent suspension and its effect on the gravity separation of formed suspension was needed. This reconsideration revealed that an unconventional, open-minded thinking was required to develop a new water purification technology capable of solving this problem. This technology will most likely be in direct disagreement with the traditional way of thinking in water purification engineering. The reconsideration project also revealed that the current method for the use of water soluble polymers results in a deterioration of the purified water quality and detrimentally affects the operation of filters. Therefore the development of a method for using these polymers, free of side effects, is also essential. A new technology, the High Rate Clarification Technology, combining two processes developed for addressing the above shortcomings, was developed.
- 22 February 2024
- Published by Global Journals in Global Journal of Researches in Engineering
- Vol. 24 (E1) , 35-67
Open AccessHigh Rate Water Clarification Technology
At present the formation of flocculent suspension and its gravity separation are lengthy processes varying between 3 and 4.5 hours. Consequently this results in high capital costs. Therefore, reconsideration of the kinetics of formation of the flocculent suspension and its effect on the gravity separation of formed suspension was needed. This reconsideration revealed that an unconventional, open-minded thinking was required to develop a new water purification technology capable of solving this problem. This technology will most likely be in direct disagreement with the traditional way of thinking in water purification engineering. The reconsideration project also revealed that the current method for the use of water soluble polymers results in a deterioration of the purified water quality and detrimentally affects the operation of filters. Therefore the development of a method for using these polymers, free of side effects, is also essential. A new technology, the High Rate Clarification Technology, combining two processes developed for addressing the above shortcomings, was developed.
- Open Access
- 31 July 2023
- Published by Academy of Science of South Africa in Water SA
- Vol. 49 (3 July) , 311-319
The inability of organic coagulants to purify potable water to its best attainable quality
Organic coagulants have gained increasing popularity over the past 30 years because they are considered cheaper and more user-friendly than traditional mineral hydrolysing coagulants. Regrettably, in-depth studies have not yet been conducted on their ability to purify water to a healthy palatable drinking quality which is risk-free for lifetime consumption in terms of the national standard for drinking water quality of various countries worldwide, and does not become a source of secondary pollution in the reticulation system. The objective of this paper is to provide information about the natural organic matter (NOM) removal efficiency attained at different waterworks purifying water with different organic coagulants, and to compare this with that attained using mineral coagulants. The findings presented in this article prove that organic coagulants are not an equivalent replacement for mineral coagulants, as the purified water is of an inferior quality which does not comply with the limits set by national standards of different countries worldwide.
- 31 July 2023
- Published by Academy of Science of South Africa in Water SA
- Vol. 49 (3 July) , 311-319
Open AccessThe inability of organic coagulants to purify potable water to its best attainable quality
Organic coagulants have gained increasing popularity over the past 30 years because they are considered cheaper and more user-friendly than traditional mineral hydrolysing coagulants. Regrettably, in-depth studies have not yet been conducted on their ability to purify water to a healthy palatable drinking quality which is risk-free for lifetime consumption in terms of the national standard for drinking water quality of various countries worldwide, and does not become a source of secondary pollution in the reticulation system. The objective of this paper is to provide information about the natural organic matter (NOM) removal efficiency attained at different waterworks purifying water with different organic coagulants, and to compare this with that attained using mineral coagulants. The findings presented in this article prove that organic coagulants are not an equivalent replacement for mineral coagulants, as the purified water is of an inferior quality which does not comply with the limits set by national standards of different countries worldwide.