Abdesselam Belkheir
Research Subjects
Abdesselam Belkheir has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Amar Benaissa
Department of Electrical Engineering, University of Djelfa, Djelfa, Algeria
2 shared publications - Mohamed Fouad Benkhoris
IREENA Laboratory, Nantes University, 44600 Saint-Nazaire, France
2 shared publications - Ouahid Bouchhida
Laboratoire de Recherche en Electrotechnique et Automatique, Departement of Technlogy, University of Médéa
2 shared publications - Samir Meradi
LCP, Hassen Badi BP 182 El Harrach, ENP, Algeria
2 shared publications
Latest Publications
- Open Access
- 1 January 2025
- Published by GN1 Sistemas e Publicacoes Ltd. in ITEGAM- Journal of Engineering and Technology for Industrial Applications (ITEGAM-JETIA)
- Vol. 11 (51) , 90-98
Fault diagnosis and fault-tolerant control strategy for interleaved boost DC/DC converter dedicated to PEM fuel cell applications
This paper proposes an improved fault diagnosis and fault tolerant control (FTC) strategy for interleaved boost DC/DC converter that is suitable for fuel-cell applications. This paper investigates a two-phase interleaved boost DC-DC converter. This design offers several advantages, including: Low ripple current, by splitting the load current between two phases, the ripple current at the input and output is significantly reduced compared to a single-phase converter. Reduced semiconductor stress, Each phase handles only a fraction (1/N) of the total current, which reduces stress on individual components and promotes higher reliability and operating margins. Furthermore, the paper proposes and evaluates an H-infinity controller for the converter. This advanced control strategy ensures robust performance despite variations in reference voltage and load conditions. The power converter suffers from failure switching due to various factors. To address these drawbacks and achieve both accurate reference tracking with desired dynamic response and rapid fault detection, an algorithm based on current-slopes are proposed. Minimizing current ripples is crucial to ensure the longevity of PEMFCs, so the interleaved boost converter structure is dedicated to the PEMFCs in order to reduces the ripple of the generated current. The overall system has been simulated using MATLAB/Simulink software under different conditions such as reference voltage variation, load variation, and Short Circuit default ; the obtained results in different phase demonstrate the higher performance, of the proposed systems in terms of dynamic performance, fast fault detection and fault tolerant action to restore the health stat. Este trabajo propone una estrategia mejorada de diagnóstico de fallos y control tolerante a fallos (FTC) para convertidores DC/DC boost intercalados que es adecuada para aplicaciones de pilas de combustible. Este trabajo investiga un convertidor DC-DC boost intercalado de dos fases. Este diseño ofrece varias ventajas, entre ellas Baja corriente de rizado, al dividir la corriente de carga entre dos fases, la corriente de rizado en la entrada y la salida se reduce significativamente en comparación con un convertidor monofásico. Reducción del estrés de los semiconductores, cada fase maneja sólo una fracción (1/N) de la corriente total, lo que reduce el estrés de los componentes individuales y favorece una mayor fiabilidad y márgenes de funcionamiento. Además, el artículo propone y evalúa un controlador H-infinito para el convertidor. Esta estrategia de control avanzada garantiza un rendimiento robusto a pesar de las variaciones en la tensión de referencia y las condiciones de carga. El convertidor de potencia sufre fallos de conmutación debidos a diversos factores. Para abordar estos inconvenientes y lograr tanto un seguimiento preciso de la referencia con la respuesta dinámica deseada como una rápida detección de fallos, se propone un algoritmo basado en ondulaciones de corriente. La minimización de las ondulaciones de corriente es crucial para garantizar la longevidad de las PEMFC, por lo que la estructura del convertidor elevador intercalado se dedica a las PEMFC con el fin de reducir la ondulación de la corriente generada. El sistema global se ha simulado utilizando el software MATLAB/Simulink bajo diferentes condiciones como variación de la tensión de referencia, variación de la carga y Corto-circuito por defecto ; los resultados obtenidos en diferentes fases demuestran el mayor rendimiento, de los sistemas propuestos en términos de rendimiento dinámico, detección rápida de fallos y acción tolerante a fallos para restaurar el estado de salud. Este artigo propõe uma estratégia aprimorada de diagnóstico de falhas e controle tolerante a falhas (FTC) para o conversor CC/CC com reforço intercalado, adequado para aplicações em células de combustível. Este artigo investiga um conversor CC-CC de impulso intercalado de duas fases. Esse projeto oferece várias vantagens, inclusive: Baixa corrente de ondulação: ao dividir a corrente de carga entre duas fases, a corrente de ondulação na entrada e na saída é significativamente reduzida em comparação com um conversor monofásico. Redução do estresse do semicondutor, cada fase lida com apenas uma fração (1/N) da corrente total, o que reduz o estresse em componentes individuais e promove maior confiabilidade e margens operacionais. Além disso, o documento propõe e avalia um controlador H-infinity para o conversor. Essa estratégia de controle avançada garante um desempenho robusto apesar das variações na tensão de referência e nas condições de carga. O conversor de energia sofre com a comutação de falhas devido a vários fatores. Para resolver essas desvantagens e obter um rastreamento de referência preciso com a resposta dinâmica desejada e a detecção rápida de falhas, é proposto um algoritmo baseado em inclinações de corrente. Minimizar as ondulações de corrente é fundamental para garantir a longevidade das PEMFCs, portanto, a estrutura do conversor de reforço intercalado é dedicada às PEMFCs para reduzir a ondulação da corrente gerada. O sistema geral foi simulado usando o software MATLAB/Simulink sob diferentes condições, como variação da tensão de referência, variação da carga e curto-circuito. Os resultados obtidos em diferentes fases demonstram o desempenho superior dos sistemas propostos em termos de desempenho dinâmico, detecção rápida de falhas e ação tolerante a falhas para restaurar o estado de saúde.
- 1 January 2025
- Published by GN1 Sistemas e Publicacoes Ltd. in ITEGAM- Journal of Engineering and Technology for Industrial Applications (ITEGAM-JETIA)
- Vol. 11 (51) , 90-98
Open AccessFault diagnosis and fault-tolerant control strategy for interleaved boost DC/DC converter dedicated to PEM fuel cell applications
This paper proposes an improved fault diagnosis and fault tolerant control (FTC) strategy for interleaved boost DC/DC converter that is suitable for fuel-cell applications. This paper investigates a two-phase interleaved boost DC-DC converter. This design offers several advantages, including: Low ripple current, by splitting the load current between two phases, the ripple current at the input and output is significantly reduced compared to a single-phase converter. Reduced semiconductor stress, Each phase handles only a fraction (1/N) of the total current, which reduces stress on individual components and promotes higher reliability and operating margins. Furthermore, the paper proposes and evaluates an H-infinity controller for the converter. This advanced control strategy ensures robust performance despite variations in reference voltage and load conditions. The power converter suffers from failure switching due to various factors. To address these drawbacks and achieve both accurate reference tracking with desired dynamic response and rapid fault detection, an algorithm based on current-slopes are proposed. Minimizing current ripples is crucial to ensure the longevity of PEMFCs, so the interleaved boost converter structure is dedicated to the PEMFCs in order to reduces the ripple of the generated current. The overall system has been simulated using MATLAB/Simulink software under different conditions such as reference voltage variation, load variation, and Short Circuit default ; the obtained results in different phase demonstrate the higher performance, of the proposed systems in terms of dynamic performance, fast fault detection and fault tolerant action to restore the health stat. Este trabajo propone una estrategia mejorada de diagnóstico de fallos y control tolerante a fallos (FTC) para convertidores DC/DC boost intercalados que es adecuada para aplicaciones de pilas de combustible. Este trabajo investiga un convertidor DC-DC boost intercalado de dos fases. Este diseño ofrece varias ventajas, entre ellas Baja corriente de rizado, al dividir la corriente de carga entre dos fases, la corriente de rizado en la entrada y la salida se reduce significativamente en comparación con un convertidor monofásico. Reducción del estrés de los semiconductores, cada fase maneja sólo una fracción (1/N) de la corriente total, lo que reduce el estrés de los componentes individuales y favorece una mayor fiabilidad y márgenes de funcionamiento. Además, el artículo propone y evalúa un controlador H-infinito para el convertidor. Esta estrategia de control avanzada garantiza un rendimiento robusto a pesar de las variaciones en la tensión de referencia y las condiciones de carga. El convertidor de potencia sufre fallos de conmutación debidos a diversos factores. Para abordar estos inconvenientes y lograr tanto un seguimiento preciso de la referencia con la respuesta dinámica deseada como una rápida detección de fallos, se propone un algoritmo basado en ondulaciones de corriente. La minimización de las ondulaciones de corriente es crucial para garantizar la longevidad de las PEMFC, por lo que la estructura del convertidor elevador intercalado se dedica a las PEMFC con el fin de reducir la ondulación de la corriente generada. El sistema global se ha simulado utilizando el software MATLAB/Simulink bajo diferentes condiciones como variación de la tensión de referencia, variación de la carga y Corto-circuito por defecto ; los resultados obtenidos en diferentes fases demuestran el mayor rendimiento, de los sistemas propuestos en términos de rendimiento dinámico, detección rápida de fallos y acción tolerante a fallos para restaurar el estado de salud. Este artigo propõe uma estratégia aprimorada de diagnóstico de falhas e controle tolerante a falhas (FTC) para o conversor CC/CC com reforço intercalado, adequado para aplicações em células de combustível. Este artigo investiga um conversor CC-CC de impulso intercalado de duas fases. Esse projeto oferece várias vantagens, inclusive: Baixa corrente de ondulação: ao dividir a corrente de carga entre duas fases, a corrente de ondulação na entrada e na saída é significativamente reduzida em comparação com um conversor monofásico. Redução do estresse do semicondutor, cada fase lida com apenas uma fração (1/N) da corrente total, o que reduz o estresse em componentes individuais e promove maior confiabilidade e margens operacionais. Além disso, o documento propõe e avalia um controlador H-infinity para o conversor. Essa estratégia de controle avançada garante um desempenho robusto apesar das variações na tensão de referência e nas condições de carga. O conversor de energia sofre com a comutação de falhas devido a vários fatores. Para resolver essas desvantagens e obter um rastreamento de referência preciso com a resposta dinâmica desejada e a detecção rápida de falhas, é proposto um algoritmo baseado em inclinações de corrente. Minimizar as ondulações de corrente é fundamental para garantir a longevidade das PEMFCs, portanto, a estrutura do conversor de reforço intercalado é dedicada às PEMFCs para reduzir a ondulação da corrente gerada. O sistema geral foi simulado usando o software MATLAB/Simulink sob diferentes condições, como variação da tensão de referência, variação da carga e curto-circuito. Os resultados obtidos em diferentes fases demonstram o desempenho superior dos sistemas propostos em termos de desempenho dinâmico, detecção rápida de falhas e ação tolerante a falhas para restaurar o estado de saúde.
- Open Access
- 2 January 2024
- Published by Brazilian Journals in STUDIES IN ENGINEERING AND EXACT SCIENCES
- Vol. 5 (1) , 1166-1186
Control and fault diagnosis for two-interleaved boost converter associated with to PEMFC
Nossa empresa trabalha com publicações de artigos acadêmicos em revistas científicas especializadas e indexadas. Assim como artigos científicos e anais de congressos, encontros ou simpósios acadêmicos, ou textos independentes, todos em forma de livros eletrônicos e impressos.Também fazemos seleções de artigos referências em algumas áreas para organização de livros temáticos. Ainda, nossa empresa trabalha com traduções científicas inglês-português e português-inglês, além de traduções juramentadas.
- 2 January 2024
- Published by Brazilian Journals in STUDIES IN ENGINEERING AND EXACT SCIENCES
- Vol. 5 (1) , 1166-1186
Open AccessControl and fault diagnosis for two-interleaved boost converter associated with to PEMFC
Nossa empresa trabalha com publicações de artigos acadêmicos em revistas científicas especializadas e indexadas. Assim como artigos científicos e anais de congressos, encontros ou simpósios acadêmicos, ou textos independentes, todos em forma de livros eletrônicos e impressos.Também fazemos seleções de artigos referências em algumas áreas para organização de livros temáticos. Ainda, nossa empresa trabalha com traduções científicas inglês-português e português-inglês, além de traduções juramentadas.