Wael Joudi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Wael Joudi has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
Alberto Trentino
Faculty of Physics, University of Vienna, Boltzmanngasse 5, 1090 Vienna, Austria
2 shared publications- Jani Kotakoski
Faculty of Physics, University of Vienna, Boltzmanngasse 5, Vienna 1090, Austria
2 shared publications - Kimmo Mustonen
University of Vienna, Faculty of Physics, Vienna, Austria
2 shared publications Clemens Mangler
University of Vienna
1 shared publication- Diana Propst
University of Vienna
1 shared publication - Elena Besley
University of Nottingham
1 shared publication
Latest Publications
- Open Access
- 10 June 2025
- Published by American Chemical Society (ACS) in ACS Nano
- Vol. 19 (24) , 22032-22043
Two-Dimensional One-Atom-Thick Gold Grown on Defect-Engineered Graphene
In this work, a general route to creating two-dimensional, one-atom-thick metal layers, metallene, on functionalized graphene is proposed. To explore its viability, low-energy ion irradiation is performed to introduce vacancies into initially pristine graphene, followed by ultralow-energy gold irradiation to deposit individual gold atoms onto it. While gold freely migrates on pristine graphene, vacancies provide anchoring points where gold atoms gather and promote the growth of atomically thin nanoplatelets. The physical and chemical structure of the gold flakes is confirmed through atomic-resolution scanning transmission electron microscopy and electron energy loss spectroscopy, while their formation is investigated using ab initio simulations. The thickness and diameter of the gold flakes are directly proportional to gold ion fluence during ultralow-energy ion irradiation. Gold atoms in small gold structures are arranged in a one-atom-thick hexagonal lattice. Larger goldene platelets with lateral sizes in the range of tens of nanometers contain multiple gold layers. Mono- and few-layer flakes are metastable under continuous 60 keV electron irradiation during imaging but occasionally rotate and take small jumps as the atoms at the edges move. A reversible transformation between a flat monolayer and an amorphous three-dimensional gold cluster is observed in the experiments and is also seen in the simulations.
- 10 June 2025
- Published by American Chemical Society (ACS) in ACS Nano
- Vol. 19 (24) , 22032-22043
Open AccessTwo-Dimensional One-Atom-Thick Gold Grown on Defect-Engineered Graphene
In this work, a general route to creating two-dimensional, one-atom-thick metal layers, metallene, on functionalized graphene is proposed. To explore its viability, low-energy ion irradiation is performed to introduce vacancies into initially pristine graphene, followed by ultralow-energy gold irradiation to deposit individual gold atoms onto it. While gold freely migrates on pristine graphene, vacancies provide anchoring points where gold atoms gather and promote the growth of atomically thin nanoplatelets. The physical and chemical structure of the gold flakes is confirmed through atomic-resolution scanning transmission electron microscopy and electron energy loss spectroscopy, while their formation is investigated using ab initio simulations. The thickness and diameter of the gold flakes are directly proportional to gold ion fluence during ultralow-energy ion irradiation. Gold atoms in small gold structures are arranged in a one-atom-thick hexagonal lattice. Larger goldene platelets with lateral sizes in the range of tens of nanometers contain multiple gold layers. Mono- and few-layer flakes are metastable under continuous 60 keV electron irradiation during imaging but occasionally rotate and take small jumps as the atoms at the edges move. A reversible transformation between a flat monolayer and an amorphous three-dimensional gold cluster is observed in the experiments and is also seen in the simulations.
- Open Access
- 25 April 2025
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 134 (16) , 166102
Corrugation-Dominated Mechanical Softening of Defect-Engineered Graphene
We measure the two-dimensional elastic modulus E 2 D of atomically clean defect-engineered graphene with a known vacancy distribution and density in correlated ultrahigh vacuum experiments. The vacancies are introduced via low-energy ( < 200 eV ) Ar ion irradiation, and the atomic structure is obtained via semiautonomous scanning transmission electron microscopy and image analysis. Based on atomic force microscopy nanoindentation measurements, a decrease of E 2 D from 286 to 158 N / m is observed when measuring the same graphene membrane before and after introducing vacancies at a density of 1.0 × 10 13 cm − 2 . This decrease is significantly greater than what is predicted by most theoretical studies and in stark contrast to some measurements presented in the literature. With the assistance of atomistic simulations, we show that this softening is mostly due to corrugations caused by local strain at vacancies with two or more missing atoms, while the influence of single vacancies is negligible. We further demonstrate that the opposite effect can be measured when surface contamination is not removed before defect engineering.
- 25 April 2025
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 134 (16) , 166102
Open AccessCorrugation-Dominated Mechanical Softening of Defect-Engineered Graphene
We measure the two-dimensional elastic modulus E 2 D of atomically clean defect-engineered graphene with a known vacancy distribution and density in correlated ultrahigh vacuum experiments. The vacancies are introduced via low-energy ( < 200 eV ) Ar ion irradiation, and the atomic structure is obtained via semiautonomous scanning transmission electron microscopy and image analysis. Based on atomic force microscopy nanoindentation measurements, a decrease of E 2 D from 286 to 158 N / m is observed when measuring the same graphene membrane before and after introducing vacancies at a density of 1.0 × 10 13 cm − 2 . This decrease is significantly greater than what is predicted by most theoretical studies and in stark contrast to some measurements presented in the literature. With the assistance of atomistic simulations, we show that this softening is mostly due to corrugations caused by local strain at vacancies with two or more missing atoms, while the influence of single vacancies is negligible. We further demonstrate that the opposite effect can be measured when surface contamination is not removed before defect engineering.