Graham Spicer
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Graham Spicer has a total of 50 co-authors. Here are the top co-authors by number of shared publications:
- Guillermo J. Tearney
Wellman Center for Photomedicine, Harvard Medical School, Massachusetts General Hospital , Boston, MA 02114
2 shared publications - Aatira Vijay
Division of Cardiology, Massachusetts General Hospital, Harvard Medical School , 55 Fruit Street, Boston, MA 02114
1 shared publication - Adam Mauskapf
Division of Cardiology, Massachusetts General Hospital, Harvard Medical School , 55 Fruit Street, Boston, MA 02114
1 shared publication Aditya Kumar
Wellman Center for Photomedicine, Massachusetts General Hospital, Boston, MA 02114, USA
1 shared publication- Ahmed Tawakol
Cardiovascular Imaging Research Center (CIRC), Department of Radiology (I.H., J.M.B., M.J., L.H.C., S.E., I.L.L., M.C.L., S.A., V.K.R., B.G., S.H., A.T., M.T.L., B.F.), Massachusetts General Hospital, Harvard Medical School, Boston
1 shared publication - Alana G. Gonzales
University of Arizona, Wyant College of Optical Sciences, Tucson, Arizona, United States
1 shared publication
Latest Publications
- Top Cited Papers
- 2 April 2026
- Published by Oxford University Press (OUP) in European Heart Journal
- Vol. 47 (28) , 3800-3817
Glucagon-like peptide-1 receptor agonists reduce experimental atherosclerosis progression, inflammatory biomarkers and cardiovascular events, irrespective of hyperglycaemia and obesity
Background and Aims: Glucagon-like peptide-1 receptor agonists (GLP-1 RAs) reduce cardiovascular events. However, their impact on atherosclerosis and inflammation, regardless of diabetes or obesity, is unknown. Here, GLP-1 RA effects were investigated on (i) atherosclerosis burden and inflammation in vivo in rabbits and (ii) inflammatory biomarkers and major adverse cardiovascular events (MACE) in clinical subjects, adjusted for glycaemic and obesity status. Methods: Rabbits with atherosclerosis received liraglutide (0.1 mg/kg/day) or saline for 4 weeks. Serial intravascular ultrasound (IVUS) and near-infrared fluorescence-optical coherence tomography (NIRF-OCT) assessed plaque burden and cathepsin activity. Histological, plasma, and in vitro analyses assessed GLP-1 RA effects on atheroinflammation. A clinical study of 47,324 participants from the Mass General Brigham Biobank evaluated the association between GLP-1 RA prescription and inflammatory biomarkers [lymphocyte-based ratios and C-reactive protein (CRP)], and MACE. Analyses included multivariable regression, propensity score matching (PSM), and mediation analysis. Results: In 28 normoglycaemic, non-obese rabbits, liraglutide significantly inhibited atherosclerosis progression compared with controls [IVUS Δ percent atheroma volume: −7.8%, 95% confidence interval (CI) −11.3 to −4.2; P < .001], and reduced NIRF-OCT plaque cathepsin activity (−9.8 nM, 95% CI −18.5 to −1.1; P = .028). Liraglutide further reduced plaque cathepsin S, macrophage content, and plasma CRP levels. In vitro, multiple GLP-1 RAs suppressed cathepsin activity and inflammatory mediators in macrophages. In biobank patients, GLP-1 RA prescription associated with significantly lower levels of inflammatory biomarkers and MACE in regression and PSM analyses, with benefits persisting in subgroups stratified by body mass index or glycated haemoglobin. Mediation analysis showed inflammatory biomarkers partly contributed to this effect. Conclusions: This integrative preclinical–clinical study demonstrates that GLP-1 RAs reduce atherosclerosis progression, inflammatory biomarkers and MACE, irrespective of hyperglycaemia or obesity.
- 2 April 2026
- Published by Oxford University Press (OUP) in European Heart Journal
- Vol. 47 (28) , 3800-3817
Top Cited PapersGlucagon-like peptide-1 receptor agonists reduce experimental atherosclerosis progression, inflammatory biomarkers and cardiovascular events, irrespective of hyperglycaemia and obesity
Background and Aims: Glucagon-like peptide-1 receptor agonists (GLP-1 RAs) reduce cardiovascular events. However, their impact on atherosclerosis and inflammation, regardless of diabetes or obesity, is unknown. Here, GLP-1 RA effects were investigated on (i) atherosclerosis burden and inflammation in vivo in rabbits and (ii) inflammatory biomarkers and major adverse cardiovascular events (MACE) in clinical subjects, adjusted for glycaemic and obesity status. Methods: Rabbits with atherosclerosis received liraglutide (0.1 mg/kg/day) or saline for 4 weeks. Serial intravascular ultrasound (IVUS) and near-infrared fluorescence-optical coherence tomography (NIRF-OCT) assessed plaque burden and cathepsin activity. Histological, plasma, and in vitro analyses assessed GLP-1 RA effects on atheroinflammation. A clinical study of 47,324 participants from the Mass General Brigham Biobank evaluated the association between GLP-1 RA prescription and inflammatory biomarkers [lymphocyte-based ratios and C-reactive protein (CRP)], and MACE. Analyses included multivariable regression, propensity score matching (PSM), and mediation analysis. Results: In 28 normoglycaemic, non-obese rabbits, liraglutide significantly inhibited atherosclerosis progression compared with controls [IVUS Δ percent atheroma volume: −7.8%, 95% confidence interval (CI) −11.3 to −4.2; P < .001], and reduced NIRF-OCT plaque cathepsin activity (−9.8 nM, 95% CI −18.5 to −1.1; P = .028). Liraglutide further reduced plaque cathepsin S, macrophage content, and plasma CRP levels. In vitro, multiple GLP-1 RAs suppressed cathepsin activity and inflammatory mediators in macrophages. In biobank patients, GLP-1 RA prescription associated with significantly lower levels of inflammatory biomarkers and MACE in regression and PSM analyses, with benefits persisting in subgroups stratified by body mass index or glycated haemoglobin. Mediation analysis showed inflammatory biomarkers partly contributed to this effect. Conclusions: This integrative preclinical–clinical study demonstrates that GLP-1 RAs reduce atherosclerosis progression, inflammatory biomarkers and MACE, irrespective of hyperglycaemia or obesity.
- Open Access
- 1 February 2026
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 31 (02) , 1-12
Optical coherence tomography and elastography for ex vivo visualization of early gastric cancer
SignificanceStomach (gastric) cancer survival depends significantly on the stage in which it is detected, and surveillance with white light endoscopy exhibits poor contrast between gastric cancer and healthy tissue, especially at early stages. Early gastric cancer can exhibit changes in epithelial microstructure, including loss of regular gastric pit structure and collagen alterations which increase tissue stiffness.AimTo improve contrast between early cancer and normal tissue, we investigate the use of optical coherence tomography (OCT) and elastography (OCE) to visualize changes in tissue structure and stiffness consistent with gastric cancer.ApproachImages of eight samples of ex vivo human stomach tissue from three patients were collected with a benchtop OCT system. OCT was performed for qualitative visualization of tissue structure. OCE was then performed on 17 regions of interest using a simplified optical palpation method to extract relative stiffness measurements. A transparent silicone reference layer was placed on the tissue, and axial compression was applied. The resulting deformation (strain) of the reference layer was measured, and the corresponding stress applied to the sample surface was extracted from the characteristic stress-strain curve of the reference material. Spatially resolved stress measurements were mapped and overlaid on en face OCT images. Tissue classification was confirmed by pathology.ResultsOCT image volumes showed more distinct gastric pit and tissue layer structure, as well as less optical attenuation, in normal tissue compared to gastric metaplasia and focal signet ring cell carcinoma (SRCC). Exemplary OCE-derived stress maps showed a trend of increasing measured stress with progression of precancer (metaplasia and dysplasia) and SRCC, suggesting increased tissue stiffness.ConclusionsThis proof-of-concept study provides evidence that OCT and OCE may be capable of visualizing differences in tissue structure and stiffness between normal, metaplastic, dysplastic, and early cancerous gastric tissue, potentially providing the basis for improved screening tools with higher sensitivity.
- 1 February 2026
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 31 (02) , 1-12
Open AccessOptical coherence tomography and elastography for ex vivo visualization of early gastric cancer
SignificanceStomach (gastric) cancer survival depends significantly on the stage in which it is detected, and surveillance with white light endoscopy exhibits poor contrast between gastric cancer and healthy tissue, especially at early stages. Early gastric cancer can exhibit changes in epithelial microstructure, including loss of regular gastric pit structure and collagen alterations which increase tissue stiffness.AimTo improve contrast between early cancer and normal tissue, we investigate the use of optical coherence tomography (OCT) and elastography (OCE) to visualize changes in tissue structure and stiffness consistent with gastric cancer.ApproachImages of eight samples of ex vivo human stomach tissue from three patients were collected with a benchtop OCT system. OCT was performed for qualitative visualization of tissue structure. OCE was then performed on 17 regions of interest using a simplified optical palpation method to extract relative stiffness measurements. A transparent silicone reference layer was placed on the tissue, and axial compression was applied. The resulting deformation (strain) of the reference layer was measured, and the corresponding stress applied to the sample surface was extracted from the characteristic stress-strain curve of the reference material. Spatially resolved stress measurements were mapped and overlaid on en face OCT images. Tissue classification was confirmed by pathology.ResultsOCT image volumes showed more distinct gastric pit and tissue layer structure, as well as less optical attenuation, in normal tissue compared to gastric metaplasia and focal signet ring cell carcinoma (SRCC). Exemplary OCE-derived stress maps showed a trend of increasing measured stress with progression of precancer (metaplasia and dysplasia) and SRCC, suggesting increased tissue stiffness.ConclusionsThis proof-of-concept study provides evidence that OCT and OCE may be capable of visualizing differences in tissue structure and stiffness between normal, metaplastic, dysplastic, and early cancerous gastric tissue, potentially providing the basis for improved screening tools with higher sensitivity.
- 30 April 2025
- Published by American Association for the Advancement of Science (AAAS) in Science Translational Medicine
- Vol. 17 (796) , eado9609
A thin cryobiopsy device compatible with transnasal endoscopy for the gastrointestinal tract
Luminal organ biopsies are critical for disease diagnosis and are obtained using single-bite forceps inserted through the working channel of large endoscopes. Procedures using these endoscopes frequently require patient sedation or anesthesia and may not be feasible for use in pediatric patients. Additionally, forceps-derived biopsies can suffer from difficulty maintaining tissue orientation, crush artifacts, and lack of precise control of biopsy depth. The high cost and risks of anesthesia and sedation have driven the development of smaller endoscopes for unsedated procedures. However, reduced endoscope size limits working-channel dimensions, restricting biopsy forceps to sizes that may yield insufficient or nondiagnostic samples. To address these limitations, we developed an image-guided, depth-controlled, ultrasmall-diameter (1.2-millimeters) cryobiopsy device (μCryoProbe). We optimized the coolant flow profile into the device to enhance tissue freezing, optimizing device-tissue contact time and freezing depth. We tested the device for gastrointestinal biopsy collection in ex vivo preclinical tissues, in an in vivo porcine model, and in sedated human participants. Dimensions and quality of mucosal cryobiopsies from esophagus, stomach, and duodenum were compared with those of forceps-derived biopsies, and it was found that the μCryoProbe device consistently produced high-quality biopsies with optimal tissue orientation and no evidence of crush artifacts. We also demonstrated the ability to capture gastrointestinal biopsies from sedated human participants. By capturing large, well-oriented samples using a small-diameter biopsy tool, this technology has the potential to shift procedures from large to small endoscopes, reducing the need for sedation and improving patient diagnosis through the acquisition of tissue samples with better quality.
- 30 April 2025
- Published by American Association for the Advancement of Science (AAAS) in Science Translational Medicine
- Vol. 17 (796) , eado9609
A thin cryobiopsy device compatible with transnasal endoscopy for the gastrointestinal tract
Luminal organ biopsies are critical for disease diagnosis and are obtained using single-bite forceps inserted through the working channel of large endoscopes. Procedures using these endoscopes frequently require patient sedation or anesthesia and may not be feasible for use in pediatric patients. Additionally, forceps-derived biopsies can suffer from difficulty maintaining tissue orientation, crush artifacts, and lack of precise control of biopsy depth. The high cost and risks of anesthesia and sedation have driven the development of smaller endoscopes for unsedated procedures. However, reduced endoscope size limits working-channel dimensions, restricting biopsy forceps to sizes that may yield insufficient or nondiagnostic samples. To address these limitations, we developed an image-guided, depth-controlled, ultrasmall-diameter (1.2-millimeters) cryobiopsy device (μCryoProbe). We optimized the coolant flow profile into the device to enhance tissue freezing, optimizing device-tissue contact time and freezing depth. We tested the device for gastrointestinal biopsy collection in ex vivo preclinical tissues, in an in vivo porcine model, and in sedated human participants. Dimensions and quality of mucosal cryobiopsies from esophagus, stomach, and duodenum were compared with those of forceps-derived biopsies, and it was found that the μCryoProbe device consistently produced high-quality biopsies with optimal tissue orientation and no evidence of crush artifacts. We also demonstrated the ability to capture gastrointestinal biopsies from sedated human participants. By capturing large, well-oriented samples using a small-diameter biopsy tool, this technology has the potential to shift procedures from large to small endoscopes, reducing the need for sedation and improving patient diagnosis through the acquisition of tissue samples with better quality.