Weihao Jiang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Weihao Jiang has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Kun He
Huazhong University of Science and Technology
5 shared publications - Adam S. Kibel
Department of Urology, Brigham and Women’s Hospital, Harvard Medical School, Boston, MA 02115, USA
1 shared publication - Adil H. Haider
Center for Surgery and Public Health, Brigham and Women’s Hospital, Harvard Medical School, Boston, Massachusetts
1 shared publication - Alexander Putnam Cole
Brigham and Women’s Hospital
1 shared publication Chang Liu
School of Computer Science, Huazhong University of Science and Technology, Wuhan, China
1 shared publicationDi He
1 shared publication
Latest Publications
- 11 August 2026
- Published by Elsevier in Neurocomputing
- Vol. 704
Feature adaptive enhancement transformer for few-shot image classification
- 11 August 2026
- Published by Elsevier in Neurocomputing
- Vol. 704
Feature adaptive enhancement transformer for few-shot image classification
- 7 March 2026
- Published by Elsevier in Applied Soft Computing
- Vol. 194
Siamese transformer networks for few-shot image classification
- 7 March 2026
- Published by Elsevier in Applied Soft Computing
- Vol. 194
Siamese transformer networks for few-shot image classification
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Multimedia
- Vol. 28, 15109-15122
Bridging Image-Text Modalities: CMA-CLIP for Few-Shot Adaptation With Cross-Modal Attention
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Multimedia
- Vol. 28, 15109-15122
Bridging Image-Text Modalities: CMA-CLIP for Few-Shot Adaptation With Cross-Modal Attention
- 5 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems for Video Technology
- Vol. 35 (11) , 11028-11040
Intra-Task Mutual Attention-Based Vision Transformer for Few-Shot Learning
Humans possess remarkable ability to accurately classify new, unseen images after being exposed to only a few examples. Such ability stems from their capacity to identify common features shared between new and previously seen images while disregarding distractions such as background variations. However, for artificial neural network models, determining the most relevant features for distinguishing between two images with limited samples presents a challenge. In this paper, we propose an intra-task mutual attention method for few-shot learning, that involves splitting the support and query samples into patches and encoding them using the pre-trained Vision Transformer (ViT) architecture. Specifically, we swap the class (CLS) token and patch tokens between the support and query sets to have the mutual attention, which enables each set to focus on the most useful information. This facilitates the strengthening of intra-class representations and promotes closer proximity between instances of the same class. For implementation, we adopt the ViT-based network architecture and utilize pre-trained model parameters obtained through self-supervision. By leveraging Masked Image Modeling as a self-supervised training task for pre-training, the pre-trained model yields semantically meaningful representations while successfully avoiding supervision collapse. We then employ a meta-learning method to fine-tune the last several layers and CLS token modules. Our strategy significantly reduces the number of parameters that require fine-tuning while effectively utilizing the capability of pre-trained model. Extensive experiments show that our framework is simple, effective and computationally efficient, achieving superior performance as compared to the state-of-the-art baselines on five popular few-shot classification benchmarks under the 5-shot and 1-shot scenarios.
- 5 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems for Video Technology
- Vol. 35 (11) , 11028-11040
Intra-Task Mutual Attention-Based Vision Transformer for Few-Shot Learning
Humans possess remarkable ability to accurately classify new, unseen images after being exposed to only a few examples. Such ability stems from their capacity to identify common features shared between new and previously seen images while disregarding distractions such as background variations. However, for artificial neural network models, determining the most relevant features for distinguishing between two images with limited samples presents a challenge. In this paper, we propose an intra-task mutual attention method for few-shot learning, that involves splitting the support and query samples into patches and encoding them using the pre-trained Vision Transformer (ViT) architecture. Specifically, we swap the class (CLS) token and patch tokens between the support and query sets to have the mutual attention, which enables each set to focus on the most useful information. This facilitates the strengthening of intra-class representations and promotes closer proximity between instances of the same class. For implementation, we adopt the ViT-based network architecture and utilize pre-trained model parameters obtained through self-supervision. By leveraging Masked Image Modeling as a self-supervised training task for pre-training, the pre-trained model yields semantically meaningful representations while successfully avoiding supervision collapse. We then employ a meta-learning method to fine-tune the last several layers and CLS token modules. Our strategy significantly reduces the number of parameters that require fine-tuning while effectively utilizing the capability of pre-trained model. Extensive experiments show that our framework is simple, effective and computationally efficient, achieving superior performance as compared to the state-of-the-art baselines on five popular few-shot classification benchmarks under the 5-shot and 1-shot scenarios.
- 11 April 2025
- Published by Elsevier in Engineering Applications of Artificial Intelligence
- Vol. 152
Boosting meta-training with base class information for robust few-shot learning
- 11 April 2025
- Published by Elsevier in Engineering Applications of Artificial Intelligence
- Vol. 152
Boosting meta-training with base class information for robust few-shot learning
- Open Access
- 1 October 2023
- Published by Apex Publishing in International Journal of Radiation Research
- Vol. 21 (4) , 707-711
Computed tomography guided nerve interventional therapy in ischemic cerebrovascular disease
Background: To explore the impact of head and neck computed tomography (CT) guided nerve interventional therapy in ischemic cerebrovascular disease (ICVD) patients. Materials and Methods: Patients with ICVD (n=100) admitted to our hospital from December 2021 to December 2022 were selected and randomly allocated into control group (CG) and observation ...
- 1 October 2023
- Published by Apex Publishing in International Journal of Radiation Research
- Vol. 21 (4) , 707-711
Open AccessComputed tomography guided nerve interventional therapy in ischemic cerebrovascular disease
Background: To explore the impact of head and neck computed tomography (CT) guided nerve interventional therapy in ischemic cerebrovascular disease (ICVD) patients. Materials and Methods: Patients with ICVD (n=100) admitted to our hospital from December 2021 to December 2022 were selected and randomly allocated into control group (CG) and observation ...
- 1 December 2017
- Published by Wolters Kluwer Health in Journal of Urology
- Vol. 198 (6) , 1295-1300
The Use of Prostate Specific Antigen Screening in Purchased versus Direct Care Settings: Data from the TRICARE® Military Database
Fee for service reimbursement incentives may affect care. We compared the odds of prostate specific antigen screening among former and active duty United States military service members based on receipt of primary care from integrated military health facilities vs community providers reimbursed via fee for service. We retrospectively studied the records of all active duty and retired male service members 40 to 64 years old who were covered by the TRICARE® military health benefit in 2010. Beneficiaries may receive primary care at military run facilities via the direct care system or with private physicians via the purchased care system. We compared rates of prostate specific antigen screening between propensity score weighted cohorts of 219,290 men who received primary care in the direct care system and 177,748 who received it in the purchased care system. The screening rate was 35% in the direct care system vs 26% in the purchased care system. After propensity score weighting the former men were significantly more likely to undergo prostate specific antigen screening than men who received primary care in the purchased care system (adjusted OR 1.76, 95% CI 1.729-1.781). Age older than 52 years, rank and black race were associated with increased odds of prostate specific antigen screening in each cohort. These results suggest that salaried primary care providers employed at integrated military facilities are more likely to order prostate specific antigen screening compared to those reimbursed in a fee for service fashion by military insurance. Growing understanding of how fee for service incentives impact prostate specific antigen screening by primary care providers may enable advocates and policy makers to leverage reimbursement systems as a tool to change prostate cancer screening.
- 1 December 2017
- Published by Wolters Kluwer Health in Journal of Urology
- Vol. 198 (6) , 1295-1300
The Use of Prostate Specific Antigen Screening in Purchased versus Direct Care Settings: Data from the TRICARE® Military Database
Fee for service reimbursement incentives may affect care. We compared the odds of prostate specific antigen screening among former and active duty United States military service members based on receipt of primary care from integrated military health facilities vs community providers reimbursed via fee for service. We retrospectively studied the records of all active duty and retired male service members 40 to 64 years old who were covered by the TRICARE® military health benefit in 2010. Beneficiaries may receive primary care at military run facilities via the direct care system or with private physicians via the purchased care system. We compared rates of prostate specific antigen screening between propensity score weighted cohorts of 219,290 men who received primary care in the direct care system and 177,748 who received it in the purchased care system. The screening rate was 35% in the direct care system vs 26% in the purchased care system. After propensity score weighting the former men were significantly more likely to undergo prostate specific antigen screening than men who received primary care in the purchased care system (adjusted OR 1.76, 95% CI 1.729-1.781). Age older than 52 years, rank and black race were associated with increased odds of prostate specific antigen screening in each cohort. These results suggest that salaried primary care providers employed at integrated military facilities are more likely to order prostate specific antigen screening compared to those reimbursed in a fee for service fashion by military insurance. Growing understanding of how fee for service incentives impact prostate specific antigen screening by primary care providers may enable advocates and policy makers to leverage reimbursement systems as a tool to change prostate cancer screening.