Si Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Si Zhang has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Abhishek Komandur1 shared publication
- Ashwin Shirsat
Department of Electrical and Computer Engineering North Carolina State University 27695 Raleigh NC USA
1 shared publication - David Lee Lubkeman
Department of Electrical and Computer Engineering North Carolina State University 27695 Raleigh NC USA
1 shared publication - Laura Kraus1 shared publication
- Lidong Song1 shared publication
- Mesut E. Baran
Department of Electrical and Computer Engineering, North Carolina State University, Raleigh, NC, USA
1 shared publication
Latest Publications
- Open Access
A TCN-based Hybrid Forecasting Framework for Hours-ahead Utility-scale PV Forecasting
This paper presents a Temporal Convolutional Network (TCN) based hybrid PV forecasting framework for enhancing hours-ahead utility-scale PV forecasting. The hybrid framework consists of two forecasting models: a physics-based trend forecasting (TF) model and a data-driven cloud-event forecasting (CF) model. Three TCNs are integrated in the framework for: i) blending the inputs from different Numerical Weather Prediction sources for the TF model to achieve superior performance on forecasting hourly PV profiles, ii) capturing spatial-temporal correlations between detector sites and the target site in the CF model to achieve more accurate forecast of intra-hour PV power drops, and iii) reconciling TF and CF results to obtain coherent hours-ahead PV forecast with both hourly trends and intra-hour fluctuations well preserved. To automatically identify the most contributive neighboring sites for forming a detector network, a scenario-based correlation analysis method is developed, which significantly improves the capability of the CF model on capturing large power fluctuations caused by cloud movements. The framework is developed, tested, and validated using actual PV data collected from 95 PV farms in North Carolina. Simulation results show that the performance of 6 hours ahead PV power forecasting is improved by approximately 20% compared with state-of-the-art methods.
Open AccessA TCN-based Hybrid Forecasting Framework for Hours-ahead Utility-scale PV Forecasting
This paper presents a Temporal Convolutional Network (TCN) based hybrid PV forecasting framework for enhancing hours-ahead utility-scale PV forecasting. The hybrid framework consists of two forecasting models: a physics-based trend forecasting (TF) model and a data-driven cloud-event forecasting (CF) model. Three TCNs are integrated in the framework for: i) blending the inputs from different Numerical Weather Prediction sources for the TF model to achieve superior performance on forecasting hourly PV profiles, ii) capturing spatial-temporal correlations between detector sites and the target site in the CF model to achieve more accurate forecast of intra-hour PV power drops, and iii) reconciling TF and CF results to obtain coherent hours-ahead PV forecast with both hourly trends and intra-hour fluctuations well preserved. To automatically identify the most contributive neighboring sites for forming a detector network, a scenario-based correlation analysis method is developed, which significantly improves the capability of the CF model on capturing large power fluctuations caused by cloud movements. The framework is developed, tested, and validated using actual PV data collected from 95 PV farms in North Carolina. Simulation results show that the performance of 6 hours ahead PV power forecasting is improved by approximately 20% compared with state-of-the-art methods.
- Open Access
A Load Switching Group based Feeder-level Microgrid Energy Management Algorithm for Service Restoration in Power Distribution System
This paper presents a load switching group based energy management system (LSG-EMS) for operating microgrids on a distribution feeder powered by one or multiple grid-forming distributed energy resources. Loads on a distribution feeder are divided into load switching groups that can be remotely switched on and off. The LSG-EMS algorithm, formulated as a mixed-integer linear programming (MILP) problem, has an objective function of maximizing the served loads while minimizing the total number of switching actions. A new set of topology constraints are developed for allowing multiple microgrids to be formed on the feeder and selecting the optimal supply path. Customer comfort is accounted for by maximizing the supply duration in the customer preferred service period and enforcing a minimum service duration. The proposed method is demonstrated on a modified IEEE 33-bus system using actual customer data. Simulation results show that the LSG-EMS successfully coordinates multiple grid-forming sources by selecting an optimal supply topology that maximizes the supply period of both the critical and noncritical loads while minimizing customer service interruptions in the service restoration process.
Open AccessA Load Switching Group based Feeder-level Microgrid Energy Management Algorithm for Service Restoration in Power Distribution System
This paper presents a load switching group based energy management system (LSG-EMS) for operating microgrids on a distribution feeder powered by one or multiple grid-forming distributed energy resources. Loads on a distribution feeder are divided into load switching groups that can be remotely switched on and off. The LSG-EMS algorithm, formulated as a mixed-integer linear programming (MILP) problem, has an objective function of maximizing the served loads while minimizing the total number of switching actions. A new set of topology constraints are developed for allowing multiple microgrids to be formed on the feeder and selecting the optimal supply path. Customer comfort is accounted for by maximizing the supply duration in the customer preferred service period and enforcing a minimum service duration. The proposed method is demonstrated on a modified IEEE 33-bus system using actual customer data. Simulation results show that the LSG-EMS successfully coordinates multiple grid-forming sources by selecting an optimal supply topology that maximizes the supply period of both the critical and noncritical loads while minimizing customer service interruptions in the service restoration process.