Olesya V. Sokolova
Research Subjects
Olesya V. Sokolova has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Irina A. Filatova
Helmholtz National Medical Research Center of Eye Diseases
6 shared publications - Sergey A. Shemetov
Helmholtz National Medical Research Center of Eye Diseases
4 shared publications - Tatiana N. Kiseleva
Helmholtz National Medical Research Center of Eye Diseases
2 shared publications I. A. Sirotkina
Ural Ocular Prosthetics Center “OKORIS
1 shared publication- Ivan Nikolaevich Ponomarev
N.V. Sklifosovsky Research Institute for Emergency Medicine
1 shared publication - Kseniya V. Lugovkina
Helmholtz National Medical Research Center of Eye Diseases
1 shared publication
Latest Publications
- 5 April 2026
- Published by Real Time, Ltd. in Russian Ophthalmological Journal
- Vol. 19 (1)
The use of a combination of mesh coating based on allogeneic collagen and platelet-rich plasma lysate in the surgical treatment of symblepharon. Experimental study
Purpose of the study was to evaluate the efficacy of a combination of allogeneic collagen-based mesh covering and platelet-rich plasma (PRP) lysate for the surgical treatment of symblepharon in an animal experiment. Material and methods. The study was approved by the local ethics committee of the Helmholtz National Medical Research Center of Eye Diseases (protocol No. 63/1 dated February 16, 2023). Thirty-two mature chinchilla rabbits (64 eyes) were divided into four equal groups based on the time of withdrawal from the experiment. Collagen isolated from rabbit tendons was used to manufacture the mesh covering. Allogeneic plasma-free lysate was obtained from the venous blood of rabbits not included in the study. A 10 × 10 mm defect down to the sclera was created in the bulbar conjunctiva of the superior-inner quadrants of both eyes and covered with a membrane made of a reticular wound dressing based on allogeneic collagen. At the end of the surgery, 0,2 ml of PRP lysate was additionally injected into the conjunctiva of the left eye of all rabbits. Results. On day 45 of observation, pale pink conjunctiva was visualized in the defect area, indistinguishable from the adjacent tissues in color and density. Morphological evaluation revealed complete restoration of the histoarchitecture of the mucous membrane. The use of PRP lysate contributed to a more favorable course of the postoperative period in the first 14 days after surgery. Conclusion. The unique fibrillar structure of reticular membranes was shown to stimulate the growth of conjunctival epithelial cells and its phenotypic development.
- 5 April 2026
- Published by Real Time, Ltd. in Russian Ophthalmological Journal
- Vol. 19 (1)
The use of a combination of mesh coating based on allogeneic collagen and platelet-rich plasma lysate in the surgical treatment of symblepharon. Experimental study
Purpose of the study was to evaluate the efficacy of a combination of allogeneic collagen-based mesh covering and platelet-rich plasma (PRP) lysate for the surgical treatment of symblepharon in an animal experiment. Material and methods. The study was approved by the local ethics committee of the Helmholtz National Medical Research Center of Eye Diseases (protocol No. 63/1 dated February 16, 2023). Thirty-two mature chinchilla rabbits (64 eyes) were divided into four equal groups based on the time of withdrawal from the experiment. Collagen isolated from rabbit tendons was used to manufacture the mesh covering. Allogeneic plasma-free lysate was obtained from the venous blood of rabbits not included in the study. A 10 × 10 mm defect down to the sclera was created in the bulbar conjunctiva of the superior-inner quadrants of both eyes and covered with a membrane made of a reticular wound dressing based on allogeneic collagen. At the end of the surgery, 0,2 ml of PRP lysate was additionally injected into the conjunctiva of the left eye of all rabbits. Results. On day 45 of observation, pale pink conjunctiva was visualized in the defect area, indistinguishable from the adjacent tissues in color and density. Morphological evaluation revealed complete restoration of the histoarchitecture of the mucous membrane. The use of PRP lysate contributed to a more favorable course of the postoperative period in the first 14 days after surgery. Conclusion. The unique fibrillar structure of reticular membranes was shown to stimulate the growth of conjunctival epithelial cells and its phenotypic development.
- Open Access
- 30 March 2026
- Published by ECO-Vector LLC (Publications) in Russian Pediatric Ophthalmology
- Vol. 21 (1) , 44-52
Clinical ultrasound monitoring of results of pterygium surgery performed using Sulfacrylate medical adhesive: short communication
BACKGROUND: Pterygium is a degenerative disorder of the conjunctiva characterized by a high recurrence rate. Currently, Sulfacrylate adhesive is used in various medical fields to reduce surgery time and improve the treatment effectiveness. For pterygium treatment, the resorption rate of the adhesive film and its ability to completely resorb are important. To objectively monitor this process and the eye mucosa condition, ultrasound biomicroscopy should be used. AIM: The study aimed to perform clinical ultrasound monitoring of the results of pterygium surgery using Sulfacrylate medical adhesive. METHODS: A single-center, uncontrolled clinical study involved patients with recurrent and active primary pterygium. All the participants underwent surgery which included resection of pterygium and conjunctival autograft transplantation with graft fixation using Sulfacrylate medical adhesive. Follow-up was performed on postoperative days 3 and 7, at weeks 3, 6, 12, and month 18. Ultrasound biomicroscopy was performed in all patients at postoperative week 3 and months 6 and 12 to objectively assess changes in the sulfacrylate adhesive layer over time. RESULTS: The clinical study included 5 patients (5 eyes) aged 30 to 50 years with diagnosed pterygium. A week after surgery, complete epithelialization of the defect was achieved in all patients. By month 6 of follow-up, complete engraftment of the transplanted conjunctival flap was observed. Ultrasound biomicroscopy confirmed resorption of the adhesive film used to fix the flap. Examination at postoperative months 12 and 18 revealed no cases of pterygium recurrence. CONCLUSION: Sulfacrylate medical adhesive is promising in pterygium surgery to prevent relapses during a 18-month follow-up. Ultrasound biomicroscopy is highly effective in postoperative assessment of the anterior segment tissues after pterygium surgery.
- 30 March 2026
- Published by ECO-Vector LLC (Publications) in Russian Pediatric Ophthalmology
- Vol. 21 (1) , 44-52
Open AccessClinical ultrasound monitoring of results of pterygium surgery performed using Sulfacrylate medical adhesive: short communication
BACKGROUND: Pterygium is a degenerative disorder of the conjunctiva characterized by a high recurrence rate. Currently, Sulfacrylate adhesive is used in various medical fields to reduce surgery time and improve the treatment effectiveness. For pterygium treatment, the resorption rate of the adhesive film and its ability to completely resorb are important. To objectively monitor this process and the eye mucosa condition, ultrasound biomicroscopy should be used. AIM: The study aimed to perform clinical ultrasound monitoring of the results of pterygium surgery using Sulfacrylate medical adhesive. METHODS: A single-center, uncontrolled clinical study involved patients with recurrent and active primary pterygium. All the participants underwent surgery which included resection of pterygium and conjunctival autograft transplantation with graft fixation using Sulfacrylate medical adhesive. Follow-up was performed on postoperative days 3 and 7, at weeks 3, 6, 12, and month 18. Ultrasound biomicroscopy was performed in all patients at postoperative week 3 and months 6 and 12 to objectively assess changes in the sulfacrylate adhesive layer over time. RESULTS: The clinical study included 5 patients (5 eyes) aged 30 to 50 years with diagnosed pterygium. A week after surgery, complete epithelialization of the defect was achieved in all patients. By month 6 of follow-up, complete engraftment of the transplanted conjunctival flap was observed. Ultrasound biomicroscopy confirmed resorption of the adhesive film used to fix the flap. Examination at postoperative months 12 and 18 revealed no cases of pterygium recurrence. CONCLUSION: Sulfacrylate medical adhesive is promising in pterygium surgery to prevent relapses during a 18-month follow-up. Ultrasound biomicroscopy is highly effective in postoperative assessment of the anterior segment tissues after pterygium surgery.
- 30 September 2025
- Published by ECO-Vector LLC in Russian Pediatric Ophthalmology
- Vol. 20 (3) , 174-181
Effectiveness of modified closure technique for local conjunctival defect using sulfacrylate tissue adhesive: an experimental study
BACKGROUND: Surgical treatment of eye adnexa disorders, including symblepharon, requires effective repair techniques. An optimal material to replace the conjunctival defect is currently being sought. Given the limited volume of autologous tissues, modifying existing surgical treatment methods may allow improving the functional outcome of reconstructive surgeries. However, suturing of graft flaps is associated with an increased risk of postoperative complications. That is why flap adherence with sulfacrylate seems to be promising. AIM: This study aimed to evaluate the efficacy of partial closure of a local conjunctival defect with sulfacrylate adhesive as part of the treatment of local symblepharon in an experiment by morphological examination. METHODS: A single-center, uncontrolled, experimental study was performed. All participants were divided into three equal groups depending on the study completion date: group 1 at day 7; group 2 at day 21, and group 3 at day 45. Sulfacrylate tissue adhesive (Russia) was used in the surgery. The bulbar conjunctiva was incised in all rabbits in the superior nasal quadrant, then a 10 × 10 mm flap was created. Three fragments were cut out of the resulting flap, evenly staggered, and adhered to the exposed sclera with tissue adhesive. Approximately 27%–30% of the total area of the conjunctival defect was covered this way. The clinical condition and histology of the ocular surface tissues, including the cornea, host and graft conjunctiva, and the exposed sclera, were assessed on post-op days 7, 21, and 45. RESULTS: The experiment was conducted in 15 gray Chinchilla rabbits (30 eyes). The use of autologous conjunctival flaps as the most preferred transplant material for conjunctival defects prevented a pronounced inflammatory reaction in the postoperative period. Sulfacrylate glue for tissue adhesion significantly shortened the surgery duration and reduced injury to the grafted flaps, eliminating the need for sutures. No toxic allergic reactions or decreased depth of the conjunctival cul-de-sac were reported in all experimental cases. The adhesive film was completely resorbed by post-op day 21. CONCLUSION: Our findings show the regenerative potential of the conjunctival tissue, which requires further research and offers new perspectives for ophthalmic plastic.
- 30 September 2025
- Published by ECO-Vector LLC in Russian Pediatric Ophthalmology
- Vol. 20 (3) , 174-181
Effectiveness of modified closure technique for local conjunctival defect using sulfacrylate tissue adhesive: an experimental study
BACKGROUND: Surgical treatment of eye adnexa disorders, including symblepharon, requires effective repair techniques. An optimal material to replace the conjunctival defect is currently being sought. Given the limited volume of autologous tissues, modifying existing surgical treatment methods may allow improving the functional outcome of reconstructive surgeries. However, suturing of graft flaps is associated with an increased risk of postoperative complications. That is why flap adherence with sulfacrylate seems to be promising. AIM: This study aimed to evaluate the efficacy of partial closure of a local conjunctival defect with sulfacrylate adhesive as part of the treatment of local symblepharon in an experiment by morphological examination. METHODS: A single-center, uncontrolled, experimental study was performed. All participants were divided into three equal groups depending on the study completion date: group 1 at day 7; group 2 at day 21, and group 3 at day 45. Sulfacrylate tissue adhesive (Russia) was used in the surgery. The bulbar conjunctiva was incised in all rabbits in the superior nasal quadrant, then a 10 × 10 mm flap was created. Three fragments were cut out of the resulting flap, evenly staggered, and adhered to the exposed sclera with tissue adhesive. Approximately 27%–30% of the total area of the conjunctival defect was covered this way. The clinical condition and histology of the ocular surface tissues, including the cornea, host and graft conjunctiva, and the exposed sclera, were assessed on post-op days 7, 21, and 45. RESULTS: The experiment was conducted in 15 gray Chinchilla rabbits (30 eyes). The use of autologous conjunctival flaps as the most preferred transplant material for conjunctival defects prevented a pronounced inflammatory reaction in the postoperative period. Sulfacrylate glue for tissue adhesion significantly shortened the surgery duration and reduced injury to the grafted flaps, eliminating the need for sutures. No toxic allergic reactions or decreased depth of the conjunctival cul-de-sac were reported in all experimental cases. The adhesive film was completely resorbed by post-op day 21. CONCLUSION: Our findings show the regenerative potential of the conjunctival tissue, which requires further research and offers new perspectives for ophthalmic plastic.
- Open Access
- 17 September 2025
- Published by Real Time, Ltd. in Russian Ophthalmological Journal
- Vol. 18 (3) , 82-89
Effectiveness of inflammation treatment in patients with anophthalmos and an eye prosthesis
One of the objectives of effective ocular prosthetics is to prevent the development of pathological processes in the conjunctival cavity.Purpose: to evaluate the effectiveness of the antimicrobial drug Mitraseptin-OftalmoLOR and its combination with the antibacterial drug MoxifloxacinOptik for the treatment of the inflammatory process of the conjunctival cavity, including bacterial conjunctivitis, in patients with anophthalmos and an ocular prosthesis, as well as the quality of life of patients during the treatment.Material and methods. The study included 34 patients aged 22 to 77 years (mean age 49.5 ± 8.3 years), including 13 men (38.2 %); women — 21 (61.8 %) with anophthalmos and an ocular prosthesis due to a previous eye removal surgery. The patients were divided into 2 groups: Group I (n = 18) — patients with moderate inflammation without signs of bacterial conjunctivitis received monotherapy with the antiseptic Mitraseptin-OftalmoLOR, Group II (n = 16) — patients with signs of severe inflammation and bacterial conjunctivitis received combination therapy with the antiseptic drug Mitraseptin-OftalmoLOR and the antibacterial drug Moxifloxacin-Optik. The observation period was 15 days. All patients had smears and cultures taken from the conjunctiva, and a microbiological study was performed. The effectiveness of the treatment was assessed based on the analysis of the dynamics of clinical symptoms of inflammation. The safety and tolerability of the therapy were also assessed using a visual analogue scale, its impact on the change in the quality of life of patients using the WHOQOL-BREF scale. Ophthalmologic examination was performed dynamically at the screening stage (1 day), 7–8 and 14–15 days after the start of treatment.Results. Positive dynamics of the disease was observed in all 34 cases. Patients of group I noted significant improvement after 7–8 days, clinical recovery was noted in 100 % of cases after 14–15 days. In group II, after 7–8 days of combination therapy, 7 patients (43.7 %) had a clinical picture of recovery, after 14–15 days, no signs of inflammation in the conjunctival cavity were detected in any of the patients. All patients noted good tolerability of the prescribed therapy. Antimicrobial therapy improved the quality of life of patients with anophthalmos and an ocular prosthesis.Conclusion. The results of the study indicate high efficiency, safety and good tolerability of antimicrobial therapy using instillations of Moxifloxacin-Optik and Mitraseptin-OftalmoLOR in patients with symptoms of conjunctival inflammation and secondary bacterial infection in anophthalmos. In this case, it is advisable to prescribe a differentiated therapy regimen. The anti-inflammatory therapy regimens used in the work contributed to improving the quality of life of patients.
- 17 September 2025
- Published by Real Time, Ltd. in Russian Ophthalmological Journal
- Vol. 18 (3) , 82-89
Open AccessEffectiveness of inflammation treatment in patients with anophthalmos and an eye prosthesis
One of the objectives of effective ocular prosthetics is to prevent the development of pathological processes in the conjunctival cavity.Purpose: to evaluate the effectiveness of the antimicrobial drug Mitraseptin-OftalmoLOR and its combination with the antibacterial drug MoxifloxacinOptik for the treatment of the inflammatory process of the conjunctival cavity, including bacterial conjunctivitis, in patients with anophthalmos and an ocular prosthesis, as well as the quality of life of patients during the treatment.Material and methods. The study included 34 patients aged 22 to 77 years (mean age 49.5 ± 8.3 years), including 13 men (38.2 %); women — 21 (61.8 %) with anophthalmos and an ocular prosthesis due to a previous eye removal surgery. The patients were divided into 2 groups: Group I (n = 18) — patients with moderate inflammation without signs of bacterial conjunctivitis received monotherapy with the antiseptic Mitraseptin-OftalmoLOR, Group II (n = 16) — patients with signs of severe inflammation and bacterial conjunctivitis received combination therapy with the antiseptic drug Mitraseptin-OftalmoLOR and the antibacterial drug Moxifloxacin-Optik. The observation period was 15 days. All patients had smears and cultures taken from the conjunctiva, and a microbiological study was performed. The effectiveness of the treatment was assessed based on the analysis of the dynamics of clinical symptoms of inflammation. The safety and tolerability of the therapy were also assessed using a visual analogue scale, its impact on the change in the quality of life of patients using the WHOQOL-BREF scale. Ophthalmologic examination was performed dynamically at the screening stage (1 day), 7–8 and 14–15 days after the start of treatment.Results. Positive dynamics of the disease was observed in all 34 cases. Patients of group I noted significant improvement after 7–8 days, clinical recovery was noted in 100 % of cases after 14–15 days. In group II, after 7–8 days of combination therapy, 7 patients (43.7 %) had a clinical picture of recovery, after 14–15 days, no signs of inflammation in the conjunctival cavity were detected in any of the patients. All patients noted good tolerability of the prescribed therapy. Antimicrobial therapy improved the quality of life of patients with anophthalmos and an ocular prosthesis.Conclusion. The results of the study indicate high efficiency, safety and good tolerability of antimicrobial therapy using instillations of Moxifloxacin-Optik and Mitraseptin-OftalmoLOR in patients with symptoms of conjunctival inflammation and secondary bacterial infection in anophthalmos. In this case, it is advisable to prescribe a differentiated therapy regimen. The anti-inflammatory therapy regimens used in the work contributed to improving the quality of life of patients.
- Open Access
- 14 June 2025
- Published by Real Time, Ltd. in Russian Ophthalmological Journal
- Vol. 18 (2) , 168-172
Modern methods of eliminating conjunctival defects
The conjunctiva is a thin mucous, richly vascularized tissue lining the inner surface of the eyelids and the eyeball to the limbus and forming the space between the eyelids and the eyeball — the conjunctival sac. Performing important physiological functions, the conjunctiva is a structure necessary for maintaining the normal anatomy and physiology of the eye. Conjunctival damage due to the impact of various factors can lead to the occurrence of significant functional disorders of the eye, which must be eliminated exclusively by surgery. Surgical treatment of conditions accompanied by conjunctival deficiency is currently considered one of the urgent and difficult tasks of ophthalmic surgery. There are many treatment tactics and modifications of operations to eliminate conjunctival defects, as well as local and total symblepharon, which are united by the need to use various replacement materials after moving the patient's own tissues. At the same time, the requirements for replacement tissues are quite high: they must be clinically compatible with the body's tissues, have the necessary elasticity, and be accessible for surgical transplantation. The ideal approach is to use one's own conjunctiva, but, unfortunately, it is not always feasible. The review presents experimental and clinical results of using modern surgical tactics: transplantation of autologous and allogeneic conjunctiva, oral mucosa, amniotic membrane, Alloplant biomaterial, autologous cultured epithelial cells of the oral mucosa.
- 14 June 2025
- Published by Real Time, Ltd. in Russian Ophthalmological Journal
- Vol. 18 (2) , 168-172
Open AccessModern methods of eliminating conjunctival defects
The conjunctiva is a thin mucous, richly vascularized tissue lining the inner surface of the eyelids and the eyeball to the limbus and forming the space between the eyelids and the eyeball — the conjunctival sac. Performing important physiological functions, the conjunctiva is a structure necessary for maintaining the normal anatomy and physiology of the eye. Conjunctival damage due to the impact of various factors can lead to the occurrence of significant functional disorders of the eye, which must be eliminated exclusively by surgery. Surgical treatment of conditions accompanied by conjunctival deficiency is currently considered one of the urgent and difficult tasks of ophthalmic surgery. There are many treatment tactics and modifications of operations to eliminate conjunctival defects, as well as local and total symblepharon, which are united by the need to use various replacement materials after moving the patient's own tissues. At the same time, the requirements for replacement tissues are quite high: they must be clinically compatible with the body's tissues, have the necessary elasticity, and be accessible for surgical transplantation. The ideal approach is to use one's own conjunctiva, but, unfortunately, it is not always feasible. The review presents experimental and clinical results of using modern surgical tactics: transplantation of autologous and allogeneic conjunctiva, oral mucosa, amniotic membrane, Alloplant biomaterial, autologous cultured epithelial cells of the oral mucosa.
- 29 April 2025
- Published by ECO-Vector LLC in Russian Pediatric Ophthalmology
- Vol. 20 (1) , 20-26
Instrumental examinations in modified surgery for symblepharon with the experimental use of Sulphacrylate tissue adhesive
Surgical treatment of symblepharon aimed at eliminating conjunctival tissue deficit requires tissue grafting. To preserve as much original tissue as possible and considering the regenerative capabilities of the conjunctiva, using smaller flaps fixed with a tissue adhesive for partial repair of the defect is deemed feasible. To evaluate the conjunctiva post-surgery, state-of-the-art instruments may be used, such as ultrasound biomicroscopy (UBM) and optical coherence tomography (OCT). AIM: To study the efficacy of surgical treatment of symblepharon consisting in defect closure sealed with a sulphacrylate tissue adhesive and to analyze the adhesive resorption time and defect epithelialization rate using instrumental examination methods. MATERIAL AND METHODS: Our experimental study included 15 chinchilla rabbits (30 eyes). Sulphacrylate tissue adhesive was used for flap fixation. Biomicroscopy, photographing, ultrasound biomicroscopy, and optical coherence tomography were used for follow-up examinations. RESULTS: No pronounced inflammation was seen with autologous tissue transplant and Sulphacrylate tissue adhesive. On Day 21 post-surgery, tissue swelling reduced significantly. The adhesive seal was gradually resorbed in the eye tissues, and the exposed scleral area was covered with conjunctiva by Day 21 post-surgery. CONCLUSION: Fixing smaller flaps to the defect bed with the sulphacrylate tissue adhesive enables tight and rapid fixation of free conjunctival flaps. The use of this modified technique for surgical treatment of symblepharon may prove successful.
- 29 April 2025
- Published by ECO-Vector LLC in Russian Pediatric Ophthalmology
- Vol. 20 (1) , 20-26
Instrumental examinations in modified surgery for symblepharon with the experimental use of Sulphacrylate tissue adhesive
Surgical treatment of symblepharon aimed at eliminating conjunctival tissue deficit requires tissue grafting. To preserve as much original tissue as possible and considering the regenerative capabilities of the conjunctiva, using smaller flaps fixed with a tissue adhesive for partial repair of the defect is deemed feasible. To evaluate the conjunctiva post-surgery, state-of-the-art instruments may be used, such as ultrasound biomicroscopy (UBM) and optical coherence tomography (OCT). AIM: To study the efficacy of surgical treatment of symblepharon consisting in defect closure sealed with a sulphacrylate tissue adhesive and to analyze the adhesive resorption time and defect epithelialization rate using instrumental examination methods. MATERIAL AND METHODS: Our experimental study included 15 chinchilla rabbits (30 eyes). Sulphacrylate tissue adhesive was used for flap fixation. Biomicroscopy, photographing, ultrasound biomicroscopy, and optical coherence tomography were used for follow-up examinations. RESULTS: No pronounced inflammation was seen with autologous tissue transplant and Sulphacrylate tissue adhesive. On Day 21 post-surgery, tissue swelling reduced significantly. The adhesive seal was gradually resorbed in the eye tissues, and the exposed scleral area was covered with conjunctiva by Day 21 post-surgery. CONCLUSION: Fixing smaller flaps to the defect bed with the sulphacrylate tissue adhesive enables tight and rapid fixation of free conjunctival flaps. The use of this modified technique for surgical treatment of symblepharon may prove successful.