SVSebastian Vuong

Sebastian Vuong

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Sebastian Vuong has a total of 29 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Blood products in High Arctic military operations: Logistics, cold‐chain performance, and post‐deployment assessment

    by Kanwal Singh, Philippe F. Simon, Alex P. Di Battista, Aron A. Shoara, Jayme Kurach, Nishaka William, Sanewal Singh, Pierre‐Marc Dion, Laura Lester, Damien Miller, et al.

    Background: Early blood transfusion in hemorrhagic patients saves lives. This study seeks to demonstrate operational capability to deploy blood to the High Arctic, while evaluating performance of blood transport containers and transfusion suitability and functional integrity of blood products post‐deployment. Study Design: Blood products (whole blood [5 units], packed red blood cells [pRBCs; 5 units], dried plasma [2 units], fibrinogen concentrate [2 units]) were deployed by the Canadian Armed Forces to Resolute Bay and Eureka, NU using passive (Crēdo 4 Nested; Golden Hour Mobile [GH‐Mobile]) and active (RINIX) blood transport systems, with continuous temperature monitoring. Post‐deployment testing assessed hemolysis, hematologic indices, coagulation function, biochemical parameters, and citrate stability in blood collection kits. Results: A continuous cold‐chain was successfully maintained throughout the 3‐week exercise, deploying blood from southern Canada to the High Arctic. RINIX served as the primary operational refrigerated storage at Role 1 facilities, while the Crēdo 4 Nested provided superior thermal protection during movement phases. Extreme cold conditions reduced GH‐Mobile performance to ~2–3 h, limiting its utility for rapid field blood delivery. Phase‐change material required modified conditioning at 4°C and ≥30 min equilibration to mitigate inadvertent freezing. Whole blood largely maintained transfusion suitability with preserved cell integrity and hemostatic function, while pRBCs preserved cell integrity. Lyophilized products retained functional integrity despite sub‐zero and freeze–thaw exposure, while citrate solution remained functional after thermal excursions. Conclusion: Deployment of blood to the High Arctic is feasible; however, logistical complexities remain the principal barrier in sustaining transfusion capability in this austere environment.

  • Open Access

    Dried plasma retains hemostatic function and thermal stability during Arctic military operations

    by Kanwal Singh, Aron A. Shoara, Henry T. Peng, Viktor Prifti, Katy Moes, Cerys McGuinness, Tristan Bonnici, Maria Shiu, Sushmaa Chandralekha Selvakumar, Peter Andrisani, et al.

    Background: Dried plasma offers a practical alternative for remote damage control resuscitation, providing hemostatic support and volume replacement. The Arctic presents challenges that necessitate the need for blood‐based resuscitation to extend the “golden hour.” To address this, we evaluated the hemostatic and thermal stability of dried plasma following exposure during military Arctic operations. Study Design and Methods: OctaplasLG powder kits were deployed with Canadian Armed Forces medical providers during three Arctic operations. Dried plasma was subjected to substantial temperature fluctuations (−35.2 to 26.5°C) and multiple freeze–thaw cycles. Upon return, dried plasma was reconstituted and evaluated using hemostatic/coagulation panels and differential scanning calorimetry (DSC). Results: Arctic‐exposed dried plasma retained visual integrity and protein concentration consistent with controls. Hemostatic function, including prothrombin time, activated partial thromboplastin time, fibrinogen, D‐dimer, factor V, factor VIII, plasminogen, antithrombin III, protein C, ADAMTS13, and viscoelastic profiles remained within normal ranges, with protein S activity below the lower limit. However, von Willebrand factor antigen levels were elevated in both dried plasma groups, though distribution remained normal and unlikely to be clinically significant for resuscitation. DSC thermograms revealed five characteristic thermal transitions consistent with controls, indicating preserved structural integrity. Enthalpy analysis demonstrated a strong correlation with fibrinogen concentration, suggesting its role in plasma stability. Conclusion: Dried plasma retains its hemostatic and thermal stability following Arctic deployment, supporting remote damage control resuscitation in the absence of whole blood. Nonetheless, field implementation is challenged by the propensity of the diluent to freeze and the logistical requirement for warmed infusion.


  • Open Access

    Profound Thrombocytopenia and Dyspnea 11 Days After Cardiac Surgery

    by Sebastian Vuong, Menaka Pai, Sarah Patterson, Theodore E. Warkentin